* '''Important:''' The uniform the patient is wearing usually covers both legs, arms, groin and torso. Helmets, eyewear and masks always obscure the eyes, make sure to remove them if working on the eyes.
* '''Important:''' The uniform the patient is wearing usually covers both legs, arms, groin and torso. Helmets, eyewear and masks always obscure the eyes, make sure to remove them if working on the eyes.
Step 2: [[File:Surgery_table.png|Operating Table]] Place the patient onto the '''operating table'''. Do this doing a{{Grab}}on the patient. Then left click the operating table to place the patient on it. You can also{{Rightclick}}shove a person onto the table and tell them to rest, though they might not appreciate this.
Step 2: [[File:Surgery table.png|Operating Table]] Place the patient onto the '''operating table'''. Do this doing a {{Grab}}on the patient. Then left click the operating table to place the patient on it. You can also {{Rightclick}} shove a person onto the table and tell them to rest, though they might not appreciate this.
* If there is no operating table, you can use: '''[[Machines#Lifeform Stasis Unit|Stasis bed]]''' (1.15x), '''any table''' (1.25x), '''any bed''' (1.5x), ask them to lie '''on the floor''' (2x). The [[User:Pink7274/sandbox#Surgery Speed and Failure|speed]] of completing every step will be reduced.
* If there is no operating table, you can use: '''[[Machines#Lifeform Stasis Unit|Stasis bed]]''' (1.15x), '''any table''' (1.25x), '''any bed''' (1.5x), ask them to lie '''on the floor''' (2x). The [[User:Pink7274/sandbox#Surgery Speed and Failure|speed]] of completing every step will be reduced.
Line 33:
Line 33:
* The stronger the alcohol, the more effective! The formula is: (booze power / 650). For example: Ethanol gives ~0.9x surgery speed, Manly Dorf ~0.85x, Bacchus' Blessing ~0.5x.
* The stronger the alcohol, the more effective! The formula is: (booze power / 650). For example: Ethanol gives ~0.9x surgery speed, Manly Dorf ~0.85x, Bacchus' Blessing ~0.5x.
Step 2.2: [[File:N2Otank.png|Sleeping Agent]] (Optional) Use a '''tank of anesthetic''' and a '''breath mask''' to make your patient sleep. This way patient won't experience agonizing pain, decreasing its [[mood]].
Step 2.2: [[File:N2Otank.png|Sleeping Agent]] (Optional) Use a '''tank of anesthetic''' and a '''breath mask''' to make your patient sleep. This way patient won't experience agonizing pain, decreasing their [[mood]].
Step 3: [[File:Drapes.png|Drapes]] [[File:Bedsheet.png|Bedsheet]] Place '''drapes''' or '''bedsheet''' over the part of body you are operating.
Step 3: [[File:Drapes.png|Drapes]] [[File:Bedsheet.png|Bedsheet]] (Optional if the patient is buckled to an '''operating table''' ) Place '''drapes''' or '''bedsheet''' over the part of body you are operating.
* If you done step 1 wrong, it will tell you that you must remove clothing first. If you continue without fixing, you will stab your patient instead of doing surgery.
* If you performed step 1 wrong, it will tell you that you must remove clothing first. If you continue without fixing it, you will stab your patient instead of doing surgery.
Step 4: Turn off{{Combat_Mode}}. Pro tip:{{Rightclick}}will make you fail every surgery step on purpose.
Step 4: Turn off {{Combat_Mode}}. Pro tip: {{Rightclick}} will make you fail every surgery step on purpose.
Step 5: [[File:Hud-target.gif|Target]] '''Aim''' at the appropriate body part (important!).
Step 5: [[File:Hud-target.gif|Target]] '''Aim''' at the appropriate body part (important!).
Line 49:
Line 51:
While a patient's undergoing surgery, they will slowly lose blood. Try not to dawdle!
While a patient's undergoing surgery, they will slowly lose blood. Try not to dawdle!
* Note: Some patients you receive will be in a state already ready for suregry! Species like [[Plasmamen]] have no skin, so you have nothing to make an incision in. You can simply skip that step!
* Note: Some patients you receive will be in a state already ready for surgery! Species like [[Guide_to_races#Plasmamen|'''Plasmamen''']] have no skin, and folk with grievous chest wounds clearly have their skin open already, so you have nothing to make an incision in. You can simply skip that step!
Step 7: '''Complete your surgery'''
Step 7: '''Complete your surgery'''
Line 64:
Line 66:
And you're done! Send the patient out with a lollipop and a smile.
And you're done! Send the patient out with a lollipop and a smile.
{{Speech
|name=Dr. Ners
|text=When performing surgery on species that have no skin such as golems or plasmamen, a widened chest cavity can be closed using a retractor! And remember to use your operating computer if you get lost.
|image=[[File:Generic_cmo.png|right]]
}}
= Weird Organs and You =
Many species contain unique organs that might not be easily identifiable in function. And as such we've compiled a list of them to familiarize yourself with should you have the unfortunate responsibility of having to take them out or stick them into your fellow crewmember. Or fortunate- if you're into that sort of thing. This is not a complete list, and is meant to help you with some niche edge cases you might come across while doing surgery.
===Ethereals===
*Electric Discharger - Tongue
*Crystal Core - Heart
*Aeration Reticulum - Lungs
*Biological Battery - Stomach
Ethereals contain a normal Liver, Appendix, Eyes, and Ears.
===Flypersons===
A truly harrowing case should they ever happen to come across your operating table, Flypersons not only have superfluous organs, but their organ names and icons are randomly generated from a pool. When in doubt, put everything you can back inside and call it a day.
===Golems===
*Crystalline Matrix - Brain
*Resonating Crystal - Eyes
*Porous Rock - Replaces the Liver, gives nutrients from minerals
*Silicate Grinder - Stomach, rejects normal consumables- only allowing the golem to eat minerals
*Internal Forge - Replaces the appendix, allows the golem to smelt minerals
Golems do not have a heart or lungs, nor equivalent organs for such.
===Hemophages===
*Atrophied Lungs - Lungs, not actually required for hemophages to survive since they don't breathe normally.
*Pulsating Tumor - Heart, gives the hemophage their abilities and corrupts normal organs into hemophage variants.
*Corrupted Stomach - Stomach, Doesn't allow the hemophage to consume most things except for blood, normally.
Other corrupted organs function the same as their normal counterparts.
===Plasmamen===
*Plasma Filter - Lungs
*Reagent Processing Crystal - Liver
*Digestive Crystal - Stomach
Plasmamen do not have a heart or appendix, nor equivalent organs for such.
===Podpersons===
*Pod Nucleus - Brain
*Pod Mitochondria - Heart
*Pod Vacuole - Lungs
*Pod Peroxisome - Liver
*Pod Chloroplast - Stomach
*Pod Endoplasmic Reticulum / Golgi Apparatus / Plastid / Vesicle - Appendix, name generated from a pool
===Slimepersons===
*Core - Brain
*Core Audiosomes - Ears
*Photosensitive Eyespots - Eyes
*Slime Vacuole - Lungs
*Endoplasmic Reticulum - Liver
*Golgi Apparatus - Stomach
Slimes do not contain an appendix, nor an equivalent organ for such.
= Operations =
= Operations =
Line 70:
Line 131:
'''Green''' operations are mechanical surgeries and will only work on cybernetic patients.
'''Green''' operations are mechanical surgeries and will only work on cybernetic patients.
'''Purple''' operations are locked - typically behind technology from science, but sometimes behind rare or traitorous surgical disks. They cannot be undergone without first being loaded into an operating computer.{{Autowiki/SurgeryTableTemplate|content={{Autowiki/SurgeryTemplate|name=Engine Diagnostic (Heart Surgery)|description=Graft a bypass onto a patient's damaged heart to restore proper blood flow. This procedure can only be performed once per organ.|hard_requirements=<ul><li>Operate on heart (target chest)</li><li>The skin must be open</li><li>The organs must be cut</li><li>The bone must be sawed</li><li>The patient must be lying down</li><li>The organ must be moderately damaged</li></ul>|soft_requirements=|optional_requirements=|blocker_requirements=<ul><li>The operation site must not be obstructed by clothing</li><li>The organ must not be organic</li><li>The organ must not have been surgically repaired prior</li></ul>|tools={{Autowiki/SurgeryToolTemplate|tool_multiplier=1.05|tool_name=Crowbar|tool_icon=surgery_tool_crowbar}}{{Autowiki/SurgeryToolTemplate|tool_multiplier=1.05|tool_name=Scalpel|tool_icon=surgery_tool_scalpel}}{{Autowiki/SurgeryToolTemplate|tool_multiplier=1.5|tool_name=Energy sword|tool_icon=surgery_tool_energy_sword}}{{Autowiki/SurgeryToolTemplate|tool_multiplier=2.25|tool_name=Knife|tool_icon=surgery_tool_knife}}{{Autowiki/SurgeryToolTemplate|tool_multiplier=2.85|tool_name=Shard|tool_icon=surgery_tool_shard}}|icon=surgery_organrepaircoronary_bypassmechanic|cstyle=background-color: #44964A; color: #FFFFFF;}}{{Autowiki/SurgeryTemplate|name=Add dental implant|description=Implant a pill into a patient's teeth.|hard_requirements=<ul><li>Operate on mouth (target mouth)</li><li>The skin must be open</li><li>The bone must be drilled</li><li>The patient must be lying down</li><li>The mouth must have teeth</li></ul>|soft_requirements=|optional_requirements=|blocker_requirements=<ul><li>The blood vessels must not be unclamped</li><li>The operation site must not be obstructed by clothing</li></ul>|tools={{Autowiki/SurgeryToolTemplate|tool_multiplier=1|tool_name=Pill|tool_icon=surgery_tool_pill}}|icon=surgery_limbadd_dental_implant|cstyle=}}{{Autowiki/SurgeryTemplate|name=Disarticulation (Amputation)|description=Sever a limb from a patient's body.|hard_requirements=<ul><li>The skin must be open</li><li>The bone must be sawed</li><li>The patient must be lying down</li></ul>|soft_requirements=|optional_requirements=|blocker_requirements=<ul><li>The blood vessels must not be unclamped</li><li>The operation site must not be obstructed by clothing</li><li>The limb must not be cybernetic</li></ul>|tools={{Autowiki/SurgeryToolTemplate|tool_multiplier=0.33|tool_name=Amputation shears|tool_icon=surgery_tool_amputation_shears}}{{Autowiki/SurgeryToolTemplate|tool_multiplier=1|tool_name=Saw|tool_icon=surgery_tool_saw}}{{Autowiki/SurgeryToolTemplate|tool_multiplier=1|tool_name=Scalpel|tool_icon=surgery_tool_scalpel}}{{Autowiki/SurgeryToolTemplate|tool_multiplier=1.25|tool_name=Arm blade|tool_icon=surgery_tool_arm_blade}}{{Autowiki/SurgeryToolTemplate|tool_multiplier=1.33|tool_name=Serrated bone shovel|tool_icon=surgery_tool_serrated_bone_shovel}}{{Autowiki/SurgeryToolTemplate|tool_multiplier=2|tool_name=Fire axe|tool_icon=surgery_tool_fire_axe}}{{Autowiki/SurgeryToolTemplate|tool_multiplier=2.5|tool_name=Hatchet|tool_icon=surgery_tool_hatchet}}{{Autowiki/SurgeryToolTemplate|tool_multiplier=4|tool_name=Butcher's cleaver|tool_icon=surgery_tool_butcher's_cleaver}}|icon=surgery_limbamputate|cstyle=}}{{Autowiki/SurgeryTemplate|name=Augmentation|description=Replace a patient's limb with a robotic or prosthetic one.|hard_requirements=<ul><li>The skin must be open</li><li>The patient must be lying down</li></ul>|soft_requirements=|optional_requirements=|blocker_requirements=<ul><li>The operation site must not be obstructed by clothing</li></ul>|tools={{Autowiki/SurgeryToolTemplate|tool_multiplier=1|tool_name=Limb|tool_icon=surgery_tool_limb}}|icon=surgery_limbreplace_limb|cstyle=}}{{Autowiki/SurgeryTemplate|name=Androtomy (Dissection and Autopsy)|description=Perform a detailed analysis of a deceased patient's body.|hard_requirements=<ul><li>Operate on chest (target chest)</li><li>The skin must be open</li><li>The patient must be lying down</li><li>The patient must be deceased</li><li>The patient must not have been autopsied prior</li></ul>|soft_requirements=|optional_requirements=|blocker_requirements=<ul><li>The limb must not be cybernetic</li></ul>|tools={{Autowiki/SurgeryToolTemplate|tool_multiplier=1|tool_name=Autopsy scanner|tool_icon=surgery_tool_autopsy_scanner}}|icon=surgery_limbautopsy|cstyle=}}{{Autowiki/SurgeryTemplate|name=Hemodialysis (Blood Filtration)|description=Remove unwanted chemicals from a patient's bloodstream.|hard_requirements=<ul><li>Operate on chest (target chest)</li><li>The skin must be open</li><li>The patient must be lying down</li><li>The patient must not be husked</li></ul>|soft_requirements=|optional_requirements=|blocker_requirements=<ul><li>The blood vessels must not be unclamped</li><li>The operation site must not be obstructed by clothing</li><li>The limb must not be cybernetic</li></ul>|tools={{Autowiki/SurgeryToolTemplate|tool_multiplier=1|tool_name=Blood filter|tool_icon=surgery_tool_blood_filter}}|icon=surgery_limbfilter_blood|cstyle=}}{{Autowiki/SurgeryTemplate|name=Neurosurgery (Brain Surgery)|description=Repair a patient's damaged brain tissue to restore cognitive function.|hard_requirements=<ul><li>Operate on brain (target head)</li><li>The skin must be open</li><li>The bone must be sawed</li><li>The patient must be lying down</li></ul>|soft_requirements=|optional_requirements=|blocker_requirements=<ul><li>The blood vessels must not be unclamped</li><li>The operation site must not be obstructed by clothing</li><li>The organ must not be cybernetic</li></ul>|tools={{Autowiki/SurgeryToolTemplate|tool_multiplier=1.05|tool_name=Hemostat|tool_icon=surgery_tool_hemostat}}{{Autowiki/SurgeryToolTemplate|tool_multiplier=2.85|tool_name=Screwdriver|tool_icon=surgery_tool_screwdriver}}{{Autowiki/SurgeryToolTemplate|tool_multiplier=6.67|tool_name=Pen|tool_icon=surgery_tool_pen}}|icon=surgery_organrepairbrain|cstyle=}}{{Autowiki/SurgeryTemplate|name=Cavity implant|description=Implant an item into a patient's body cavity.|hard_requirements=<ul><li>Operate on chest (target chest)</li><li>The skin must be open</li><li>The organs must be cut</li><li>The chest cavity must be opened wide</li><li>The patient must be lying down</li></ul>|soft_requirements=|optional_requirements=|blocker_requirements=<ul><li>The operation site must not be obstructed by clothing</li></ul>|tools={{Autowiki/SurgeryToolTemplate|tool_multiplier=1|tool_name=Any item|tool_icon=surgery_tool_any_item}}|icon=surgery_limbcavity_implant|cstyle=}}{{Autowiki/SurgeryTemplate|name=Clamp bleeders|description=Clamp bleeding blood vessels in the patient's body to prevent blood loss. Causes "vessels clamped" surgical state.|hard_requirements=<ul><li>The skin must be open</li><li>The blood vessels must be unclamped</li><li>The patient must be lying down</li></ul>|soft_requirements=|optional_requirements=|blocker_requirements=<ul><li>The operation site must not be obstructed by clothing</li><li>The limb must not be cybernetic</li></ul>|tools={{Autowiki/SurgeryToolTemplate|tool_multiplier=1|tool_name=Hemostat|tool_icon=surgery_tool_hemostat}}{{Autowiki/SurgeryToolTemplate|tool_multiplier=1.67|tool_name=Cutters|tool_icon=surgery_tool_cutters}}{{Autowiki/SurgeryToolTemplate|tool_multiplier=2.85|tool_name=Package wrapper|tool_icon=surgery_tool_package_wrapper}}{{Autowiki/SurgeryToolTemplate|tool_multiplier=6.67|tool_name=Cable coil|tool_icon=surgery_tool_cable_coil}}|icon=surgery_limbclamp_bleeders|cstyle=}}{{Autowiki/SurgeryTemplate|name=Debridement|description=Remove infected or necrotic flesh from a patient's wound to promote healing.|hard_requirements=<ul><li>The limb must have a second degree or worse burn</li><li>The patient must be lying down</li></ul>|soft_requirements=|optional_requirements=|blocker_requirements=<ul><li>The operation site must not be obstructed by clothing</li></ul>|tools={{Autowiki/SurgeryToolTemplate|tool_multiplier=1|tool_name=Hemostat|tool_icon=surgery_tool_hemostat}}{{Autowiki/SurgeryToolTemplate|tool_multiplier=1.25|tool_name=Scalpel|tool_icon=surgery_tool_scalpel}}{{Autowiki/SurgeryToolTemplate|tool_multiplier=1.66|tool_name=Saw|tool_icon=surgery_tool_saw}}{{Autowiki/SurgeryToolTemplate|tool_multiplier=2.5|tool_name=Cutters|tool_icon=surgery_tool_cutters}}|icon=surgery_limbdebride|cstyle=}}{{Autowiki/SurgeryTemplate|name=Detach Wooden Limb (Amputation)|description=Sever a limb from a patient's body.|hard_requirements=<ul><li>The patient must be lying down</li><li>The limb must be wooden</li></ul>|soft_requirements=|optional_requirements=|blocker_requirements=<ul><li>The blood vessels must not be unclamped</li><li>The operation site must not be obstructed by clothing</li></ul>|tools={{Autowiki/SurgeryToolTemplate|tool_multiplier=1|tool_name=Saw|tool_icon=surgery_tool_saw}}{{Autowiki/SurgeryToolTemplate|tool_multiplier=1|tool_name=Serrated bone shovel|tool_icon=surgery_tool_serrated_bone_shovel}}{{Autowiki/SurgeryToolTemplate|tool_multiplier=1.15|tool_name=Fire axe|tool_icon=surgery_tool_fire_axe}}{{Autowiki/SurgeryToolTemplate|tool_multiplier=1.33|tool_name=Hatchet|tool_icon=surgery_tool_hatchet}}{{Autowiki/SurgeryToolTemplate|tool_multiplier=4|tool_name=Scalpel|tool_icon=surgery_tool_scalpel}}|icon=surgery_limbamputatepegleg|cstyle=background-color: #44964A; color: #FFFFFF;}}{{Autowiki/SurgeryTemplate|name=Dissassembly (Amputation)|description=Sever a limb from a patient's body.|hard_requirements=<ul><li>The skin must be open</li><li>The patient must be lying down</li></ul>|soft_requirements=<ul><li>If operating on the head, the bone MUST be sawed</li><li>Otherwise, the state of the bone doesn't matter</li></ul>|optional_requirements=|blocker_requirements=<ul><li>The blood vessels must not be unclamped</li><li>The operation site must not be obstructed by clothing</li><li>The limb must not be organic</li></ul>|tools={{Autowiki/SurgeryToolTemplate|tool_multiplier=1|tool_name=Wrench|tool_icon=surgery_tool_wrench}}{{Autowiki/SurgeryToolTemplate|tool_multiplier=1|tool_name=Crowbar|tool_icon=surgery_tool_crowbar}}{{Autowiki/SurgeryToolTemplate|tool_multiplier=2|tool_name=Scalpel|tool_icon=surgery_tool_scalpel}}{{Autowiki/SurgeryToolTemplate|tool_multiplier=2|tool_name=Saw|tool_icon=surgery_tool_saw}}|icon=surgery_limbamputatemechanic|cstyle=background-color: #44964A; color: #FFFFFF;}}{{Autowiki/SurgeryTemplate|name=Discard skull debris|description=Clear away bone fragments and debris from a patient's cranial fissure in preparation for repair.|hard_requirements=<ul><li>The cranium must be fractured</li><li>The patient must be lying down</li></ul>|soft_requirements=|optional_requirements=|blocker_requirements=<ul><li>The operation site must not be obstructed by clothing</li></ul>|tools={{Autowiki/SurgeryToolTemplate|tool_multiplier=1|tool_name=Hemostat|tool_icon=surgery_tool_hemostat}}{{Autowiki/SurgeryToolTemplate|tool_multiplier=2.5|tool_name=Cutters|tool_icon=surgery_tool_cutters}}{{Autowiki/SurgeryToolTemplate|tool_multiplier=2.5|tool_name=Screwdriver|tool_icon=surgery_tool_screwdriver}}|icon=surgery_limbprepare_cranium_repair|cstyle=}}{{Autowiki/SurgeryTemplate|name=Drill limb bone|description=Drill through a patient's bones. Causes "bone drilled" surgical state.|hard_requirements=<ul><li>The skin must be open</li><li>The patient must be lying down</li></ul>|soft_requirements=|optional_requirements=|blocker_requirements=<ul><li>The bone must be intact</li><li>The operation site must not be obstructed by clothing</li><li>The limb must not be cybernetic</li></ul>|tools={{Autowiki/SurgeryToolTemplate|tool_multiplier=1|tool_name=Drill|tool_icon=surgery_tool_drill}}{{Autowiki/SurgeryToolTemplate|tool_multiplier=1.25|tool_name=Hand drill|tool_icon=surgery_tool_hand_drill}}{{Autowiki/SurgeryToolTemplate|tool_multiplier=1.67|tool_name=Mining drill|tool_icon=surgery_tool_mining_drill}}{{Autowiki/SurgeryToolTemplate|tool_multiplier=4|tool_name=Screwdriver|tool_icon=surgery_tool_screwdriver}}{{Autowiki/SurgeryToolTemplate|tool_multiplier=5|tool_name=Spoon|tool_icon=surgery_tool_spoon}}{{Autowiki/SurgeryToolTemplate|tool_multiplier=6.67|tool_name=Any sharp pointed item with decent force|tool_icon=surgery_tool_any_sharp_pointed_item_with_decent_force}}|icon=surgery_limbdrill_bones|cstyle=}}{{Autowiki/SurgeryTemplate|name=Ototomy (Ear surgery)|description=Repair a patient's damaged ears to restore hearing.|hard_requirements=<ul><li>Operate on ears (target head)</li><li>The skin must be open</li><li>The patient must be lying down</li></ul>|soft_requirements=|optional_requirements=|blocker_requirements=<ul><li>The blood vessels must not be unclamped</li><li>The operation site must not be obstructed by clothing</li><li>The organ must not be cybernetic</li><li>If the limb has bones, they must be intact</li></ul>|tools={{Autowiki/SurgeryToolTemplate|tool_multiplier=1.05|tool_name=Hemostat|tool_icon=surgery_tool_hemostat}}{{Autowiki/SurgeryToolTemplate|tool_multiplier=2.25|tool_name=Screwdriver|tool_icon=surgery_tool_screwdriver}}{{Autowiki/SurgeryToolTemplate|tool_multiplier=4|tool_name=Pen|tool_icon=surgery_tool_pen}}|icon=surgery_organrepairears|cstyle=}}{{Autowiki/SurgeryTemplate|name=Nutrient Reserve Expulsion (Excise Fat)|description=Remove excess fat from a patient's body.|hard_requirements=<ul><li>Operate on chest (target chest)</li><li>The skin must be open</li><li>The patient must be lying down</li><li>The patient must have excess fat to remove</li></ul>|soft_requirements=|optional_requirements=|blocker_requirements=<ul><li>The blood vessels must not be unclamped</li><li>The operation site must not be obstructed by clothing</li><li>The limb must not be organic</li></ul>|tools={{Autowiki/SurgeryToolTemplate|tool_multiplier=1.05|tool_name=Wrench|tool_icon=surgery_tool_wrench}}{{Autowiki/SurgeryToolTemplate|tool_multiplier=1.05|tool_name=Crowbar|tool_icon=surgery_tool_crowbar}}{{Autowiki/SurgeryToolTemplate|tool_multiplier=1.33|tool_name=Serrated bone shovel|tool_icon=surgery_tool_serrated_bone_shovel}}{{Autowiki/SurgeryToolTemplate|tool_multiplier=1.33|tool_name=Energy sword|tool_icon=surgery_tool_energy_sword}}{{Autowiki/SurgeryToolTemplate|tool_multiplier=1.67|tool_name=Saw|tool_icon=surgery_tool_saw}}{{Autowiki/SurgeryToolTemplate|tool_multiplier=3.33|tool_name=Hatchet|tool_icon=surgery_tool_hatchet}}{{Autowiki/SurgeryToolTemplate|tool_multiplier=3.33|tool_name=Knife|tool_icon=surgery_tool_knife}}{{Autowiki/SurgeryToolTemplate|tool_multiplier=4|tool_name=Scalpel|tool_icon=surgery_tool_scalpel}}{{Autowiki/SurgeryToolTemplate|tool_multiplier=5|tool_name=Any sharp edged item|tool_icon=surgery_tool_any_sharp_edged_item}}|icon=surgery_limblipoplastymechanic|cstyle=background-color: #44964A; color: #FFFFFF;}}{{Autowiki/SurgeryTemplate|name=Lobectomy (Lung Surgery)|description=Perform repairs to a patient's damaged lung by excising the most damaged lobe. This procedure can only be performed once per organ.|hard_requirements=<ul><li>Operate on lungs (target chest)</li><li>The skin must be open</li><li>The organs must be cut</li><li>The bone must be sawed</li><li>The patient must be lying down</li><li>The organ must be moderately damaged</li></ul>|soft_requirements=|optional_requirements=|blocker_requirements=<ul><li>The operation site must not be obstructed by clothing</li><li>The organ must not be cybernetic</li><li>The organ must not have been surgically repaired prior</li></ul>|tools={{Autowiki/SurgeryToolTemplate|tool_multiplier=1.05|tool_name=Scalpel|tool_icon=surgery_tool_scalpel}}{{Autowiki/SurgeryToolTemplate|tool_multiplier=1.5|tool_name=Energy sword|tool_icon=surgery_tool_energy_sword}}{{Autowiki/SurgeryToolTemplate|tool_multiplier=2.25|tool_name=Knife|tool_icon=surgery_tool_knife}}{{Autowiki/SurgeryToolTemplate|tool_multiplier=2.85|tool_name=Shard|tool_icon=surgery_tool_shard}}|icon=surgery_organrepairlobectomy|cstyle=}}{{Autowiki/SurgeryTemplate|name=Lipoplasty (Excise Fat)|description=Remove excess fat from a patient's body.|hard_requirements=<ul><li>Operate on chest (target chest)</li><li>The skin must be open</li><li>The patient must be lying down</li><li>The patient must have excess fat to remove</li></ul>|soft_requirements=|optional_requirements=|blocker_requirements=<ul><li>The blood vessels must not be unclamped</li><li>The operation site must not be obstructed by clothing</li><li>The limb must not be cybernetic</li></ul>|tools={{Autowiki/SurgeryToolTemplate|tool_multiplier=1|tool_name=Saw|tool_icon=surgery_tool_saw}}{{Autowiki/SurgeryToolTemplate|tool_multiplier=1.25|tool_name=Scalpel|tool_icon=surgery_tool_scalpel}}{{Autowiki/SurgeryToolTemplate|tool_multiplier=1.33|tool_name=Serrated bone shovel|tool_icon=surgery_tool_serrated_bone_shovel}}{{Autowiki/SurgeryToolTemplate|tool_multiplier=1.33|tool_name=Energy sword|tool_icon=surgery_tool_energy_sword}}{{Autowiki/SurgeryToolTemplate|tool_multiplier=3.33|tool_name=Hatchet|tool_icon=surgery_tool_hatchet}}{{Autowiki/SurgeryToolTemplate|tool_multiplier=3.33|tool_name=Knife|tool_icon=surgery_tool_knife}}{{Autowiki/SurgeryToolTemplate|tool_multiplier=5|tool_name=Any sharp edged item|tool_icon=surgery_tool_any_sharp_edged_item}}|icon=surgery_limblipoplasty|cstyle=}}{{Autowiki/SurgeryTemplate|name=Corectomy (Extract Core)|description=Remove the core from a slime.|hard_requirements=<ul><li>Operate on a deceased slime</li><li>Operate on chest (target chest)</li><li>The skin must be cut or opened</li></ul>|soft_requirements=|optional_requirements=|blocker_requirements=|tools={{Autowiki/SurgeryToolTemplate|tool_multiplier=1|tool_name=Hemostat|tool_icon=surgery_tool_hemostat}}{{Autowiki/SurgeryToolTemplate|tool_multiplier=1|tool_name=Crowbar|tool_icon=surgery_tool_crowbar}}|icon=surgery_basiccore_removal|cstyle=}}{{Autowiki/SurgeryTemplate|name=Vitrectomy (Eye Surgery)|description=Repair a patient's damaged eyes to restore vision.|hard_requirements=<ul><li>Operate on eyes (target eyes)</li><li>The skin must be open</li><li>The patient must be lying down</li></ul>|soft_requirements=|optional_requirements=|blocker_requirements=<ul><li>The blood vessels must not be unclamped</li><li>The operation site must not be obstructed by clothing</li><li>The organ must not be cybernetic</li><li>If the limb has bones, they must be intact</li></ul>|tools={{Autowiki/SurgeryToolTemplate|tool_multiplier=1.05|tool_name=Hemostat|tool_icon=surgery_tool_hemostat}}{{Autowiki/SurgeryToolTemplate|tool_multiplier=2.25|tool_name=Screwdriver|tool_icon=surgery_tool_screwdriver}}{{Autowiki/SurgeryToolTemplate|tool_multiplier=4|tool_name=Pen|tool_icon=surgery_tool_pen}}|icon=surgery_organrepaireyes|cstyle=}}{{Autowiki/SurgeryTemplate|name=Feature manipulation|description=Manipulate features of the patient, such as a moth's wings or a lizard's tail.|hard_requirements=<ul><li>The skin must be open</li><li>The bone must be sawed</li><li>The patient must be lying down</li></ul>|soft_requirements=|optional_requirements=|blocker_requirements=<ul><li>The blood vessels must not be unclamped</li><li>The operation site must not be obstructed by clothing</li><li>The limb must not be cybernetic</li></ul>|tools={{Autowiki/SurgeryToolTemplate|tool_multiplier=1|tool_name=Hemostat|tool_icon=surgery_tool_hemostat}}{{Autowiki/SurgeryToolTemplate|tool_multiplier=1.8|tool_name=Crowbar|tool_icon=surgery_tool_crowbar}}{{Autowiki/SurgeryToolTemplate|tool_multiplier=2.85|tool_name=Fork|tool_icon=surgery_tool_fork}}{{Autowiki/SurgeryToolTemplate|tool_multiplier=1|tool_name=Organ|tool_icon=surgery_tool_organ}}|icon=surgery_limborgan_manipulationexternal|cstyle=}}{{Autowiki/SurgeryTemplate|name=Fix limb bone|description=Repair a patient's cut or broken bones. Clears "bone sawed" and "bone drilled" surgical states.|hard_requirements=<ul><li>The skin must be open</li><li>The patient must be lying down</li><li>The limb must have bones</li><li>The bone must be sawed or drilled</li></ul>|soft_requirements=|optional_requirements=|blocker_requirements=<ul><li>The operation site must not be obstructed by clothing</li><li>The limb must not be cybernetic</li></ul>|tools={{Autowiki/SurgeryToolTemplate|tool_multiplier=1|tool_name=Bone gel|tool_icon=surgery_tool_bone_gel}}{{Autowiki/SurgeryToolTemplate|tool_multiplier=1|tool_name=Surgical tape|tool_icon=surgery_tool_surgical_tape}}{{Autowiki/SurgeryToolTemplate|tool_multiplier=2|tool_name=Super sticky tape|tool_icon=surgery_tool_super_sticky_tape}}{{Autowiki/SurgeryToolTemplate|tool_multiplier=3.33|tool_name=Sticky tape|tool_icon=surgery_tool_sticky_tape}}|icon=surgery_limbfix_bones|cstyle=}}{{Autowiki/SurgeryTemplate|name=Bronchial Dilatation (Asthmatic Bypass)|description=Forcibly expand a patient's windpipe, relieving asthma symptoms.|hard_requirements=<ul><li>The patient must be asthmatic</li><li>Operate on lungs (target chest)</li><li>The skin must be open</li><li>The organs must be cut</li><li>The patient must be lying down</li></ul>|soft_requirements=|optional_requirements=|blocker_requirements=<ul><li>The operation site must not be obstructed by clothing</li><li>The organ must not be cybernetic</li></ul>|tools={{Autowiki/SurgeryToolTemplate|tool_multiplier=1.25|tool_name=Retractor|tool_icon=surgery_tool_retractor}}{{Autowiki/SurgeryToolTemplate|tool_multiplier=2.25|tool_name=Cutters|tool_icon=surgery_tool_cutters}}|icon=surgery_organasthmatic_bypass|cstyle=}}{{Autowiki/SurgeryTemplate|name=Brain Defibrillation (Revival)|description=Use a defibrillator to shock a patient's brain back to life.|hard_requirements=<ul><li>Operate on head (target head)</li><li>The skin must be open</li><li>The bone must be sawed</li><li>The patient must be lying down</li><li>The patient must be deceased</li><li>The patient must be in a revivable state</li></ul>|soft_requirements=|optional_requirements=|blocker_requirements=<ul><li>The operation site must not be obstructed by clothing</li><li>The patient must not be organic</li></ul>|tools={{Autowiki/SurgeryToolTemplate|tool_multiplier=1|tool_name=Defibrillator paddles|tool_icon=surgery_tool_defibrillator_paddles}}{{Autowiki/SurgeryToolTemplate|tool_multiplier=1|tool_name=Shock touch|tool_icon=surgery_tool_shock_touch}}{{Autowiki/SurgeryToolTemplate|tool_multiplier=1.33|tool_name=Stun baton|tool_icon=surgery_tool_stun_baton}}{{Autowiki/SurgeryToolTemplate|tool_multiplier=1.67|tool_name=Energy gun|tool_icon=surgery_tool_energy_gun}}|icon=surgery_basicrevivalmechanic|cstyle=}}{{Autowiki/SurgeryTemplate|name=Coronary Artery Bypass Graft (Heart Surgery)|description=Graft a bypass onto a patient's damaged heart to restore proper blood flow. This procedure can only be performed once per organ.|hard_requirements=<ul><li>Operate on heart (target chest)</li><li>The skin must be open</li><li>The organs must be cut</li><li>The bone must be sawed</li><li>The patient must be lying down</li><li>The organ must be moderately damaged</li></ul>|soft_requirements=|optional_requirements=|blocker_requirements=<ul><li>The operation site must not be obstructed by clothing</li><li>The organ must not be cybernetic</li><li>The organ must not have been surgically repaired prior</li></ul>|tools={{Autowiki/SurgeryToolTemplate|tool_multiplier=1.05|tool_name=Hemostat|tool_icon=surgery_tool_hemostat}}{{Autowiki/SurgeryToolTemplate|tool_multiplier=2.85|tool_name=Cutters|tool_icon=surgery_tool_cutters}}{{Autowiki/SurgeryToolTemplate|tool_multiplier=6.67|tool_name=Package wrapper|tool_icon=surgery_tool_package_wrapper}}{{Autowiki/SurgeryToolTemplate|tool_multiplier=2|tool_name=Cable coil|tool_icon=surgery_tool_cable_coil}}|icon=surgery_organrepaircoronary_bypass|cstyle=}}{{Autowiki/SurgeryTemplate|name=Implant removal|description=Attempt to find and remove an implant from a patient. Any implant found will be destroyed unless an implant case is held or nearby.|hard_requirements=<ul><li>Operate on chest (target chest)</li><li>The skin must be open</li><li>The patient must be lying down</li></ul>|soft_requirements=|optional_requirements=<ul><li>Have an implant case below or inhand to store removed implants</li></ul>|blocker_requirements=<ul><li>The blood vessels must not be unclamped</li><li>The operation site must not be obstructed by clothing</li><li>The patient must not be robotic</li></ul>|tools={{Autowiki/SurgeryToolTemplate|tool_multiplier=1|tool_name=Hemostat|tool_icon=surgery_tool_hemostat}}{{Autowiki/SurgeryToolTemplate|tool_multiplier=1.5|tool_name=Crowbar|tool_icon=surgery_tool_crowbar}}{{Autowiki/SurgeryToolTemplate|tool_multiplier=2.85|tool_name=Fork|tool_icon=surgery_tool_fork}}|icon=surgery_basicimplant_removal|cstyle=}}{{Autowiki/SurgeryTemplate|name=Incise organs|description=Make an incision in patient's internal organ tissue to allow for manipulation or repair. Causes "organs cut" surgical state.|hard_requirements=<ul><li>The skin must be open</li><li>The patient must be lying down</li></ul>|soft_requirements=|optional_requirements=|blocker_requirements=<ul><li>The organs must not be cut</li><li>The operation site must not be obstructed by clothing</li><li>The limb must not be cybernetic</li></ul>|tools={{Autowiki/SurgeryToolTemplate|tool_multiplier=1|tool_name=Scalpel|tool_icon=surgery_tool_scalpel}}{{Autowiki/SurgeryToolTemplate|tool_multiplier=1.33|tool_name=Energy sword|tool_icon=surgery_tool_energy_sword}}{{Autowiki/SurgeryToolTemplate|tool_multiplier=1.5|tool_name=Knife|tool_icon=surgery_tool_knife}}{{Autowiki/SurgeryToolTemplate|tool_multiplier=2.25|tool_name=Shard|tool_icon=surgery_tool_shard}}{{Autowiki/SurgeryToolTemplate|tool_multiplier=5|tool_name=Pen|tool_icon=surgery_tool_pen}}{{Autowiki/SurgeryToolTemplate|tool_multiplier=3.33|tool_name=Any sharp edged item|tool_icon=surgery_tool_any_sharp_edged_item}}|icon=surgery_limbincise_organs|cstyle=}}{{Autowiki/SurgeryTemplate|name=Internal organ manipulation|description=Manipulate a patient's internal organs.|hard_requirements=<ul><li>The skin must be open</li><li>The organs must be cut</li><li>The patient must be lying down</li></ul>|soft_requirements=<ul><li>If operating on the brain or any chest organs, the bone MUST be sawed</li><li>Otherwise, the state of the bone doesn't matter</li></ul>|optional_requirements=|blocker_requirements=<ul><li>The operation site must not be obstructed by clothing</li><li>The limb must not be cybernetic</li></ul>|tools={{Autowiki/SurgeryToolTemplate|tool_multiplier=1|tool_name=Hemostat|tool_icon=surgery_tool_hemostat}}{{Autowiki/SurgeryToolTemplate|tool_multiplier=1.8|tool_name=Crowbar|tool_icon=surgery_tool_crowbar}}{{Autowiki/SurgeryToolTemplate|tool_multiplier=2.85|tool_name=Fork|tool_icon=surgery_tool_fork}}{{Autowiki/SurgeryToolTemplate|tool_multiplier=1|tool_name=Organ|tool_icon=surgery_tool_organ}}|icon=surgery_limborgan_manipulationinternal|cstyle=}}{{Autowiki/SurgeryTemplate|name=Make incision|description=Make an incision in the patient's skin to access internals. Causes "cut skin" surgical state.|hard_requirements=<ul><li>Operate on patient</li><li>The patient must be lying down</li></ul>|soft_requirements=|optional_requirements=|blocker_requirements=<ul><li>The skin must be intact</li><li>The operation site must not be obstructed by clothing</li><li>The patient must not be robotic</li><li>The patient must not have complex anatomy</li></ul>|tools={{Autowiki/SurgeryToolTemplate|tool_multiplier=1|tool_name=Scalpel|tool_icon=surgery_tool_scalpel}}{{Autowiki/SurgeryToolTemplate|tool_multiplier=1.33|tool_name=Energy sword|tool_icon=surgery_tool_energy_sword}}{{Autowiki/SurgeryToolTemplate|tool_multiplier=1.5|tool_name=Knife|tool_icon=surgery_tool_knife}}{{Autowiki/SurgeryToolTemplate|tool_multiplier=2.25|tool_name=Shard|tool_icon=surgery_tool_shard}}{{Autowiki/SurgeryToolTemplate|tool_multiplier=5|tool_name=Screwdriver|tool_icon=surgery_tool_screwdriver}}{{Autowiki/SurgeryToolTemplate|tool_multiplier=5|tool_name=Pen|tool_icon=surgery_tool_pen}}{{Autowiki/SurgeryToolTemplate|tool_multiplier=3.33|tool_name=Any sharp edged item|tool_icon=surgery_tool_any_sharp_edged_item}}|icon=surgery_basicincise_skin|cstyle=}}{{Autowiki/SurgeryTemplate|name=Make skin incision|description=Make an incision in the patient's skin to access internal organs. Causes "cut skin" surgical state.|hard_requirements=<ul><li>The patient must be lying down</li></ul>|soft_requirements=|optional_requirements=|blocker_requirements=<ul><li>The skin must be intact</li><li>The operation site must not be obstructed by clothing</li><li>The limb must not be cybernetic</li></ul>|tools={{Autowiki/SurgeryToolTemplate|tool_multiplier=1|tool_name=Scalpel|tool_icon=surgery_tool_scalpel}}{{Autowiki/SurgeryToolTemplate|tool_multiplier=1.33|tool_name=Energy sword|tool_icon=surgery_tool_energy_sword}}{{Autowiki/SurgeryToolTemplate|tool_multiplier=1.5|tool_name=Knife|tool_icon=surgery_tool_knife}}{{Autowiki/SurgeryToolTemplate|tool_multiplier=2.25|tool_name=Shard|tool_icon=surgery_tool_shard}}{{Autowiki/SurgeryToolTemplate|tool_multiplier=5|tool_name=Screwdriver|tool_icon=surgery_tool_screwdriver}}{{Autowiki/SurgeryToolTemplate|tool_multiplier=5|tool_name=Pen|tool_icon=surgery_tool_pen}}{{Autowiki/SurgeryToolTemplate|tool_multiplier=3.33|tool_name=Any sharp edged item|tool_icon=surgery_tool_any_sharp_edged_item}}|icon=surgery_limbincise_skin|cstyle=}}{{Autowiki/SurgeryTemplate|name=Make thick skin incision|description=Make an incision in the patient's skin to access internal organs. Causes "cut skin" surgical state.|hard_requirements=<ul><li>The patient must be lying down</li></ul>|soft_requirements=|optional_requirements=|blocker_requirements=<ul><li>The skin must be intact</li><li>The operation site must not be obstructed by clothing</li><li>The limb must not be cybernetic</li></ul>|tools={{Autowiki/SurgeryToolTemplate|tool_multiplier=1|tool_name=Saw|tool_icon=surgery_tool_saw}}{{Autowiki/SurgeryToolTemplate|tool_multiplier=1.25|tool_name=Energy sword|tool_icon=surgery_tool_energy_sword}}{{Autowiki/SurgeryToolTemplate|tool_multiplier=1.5|tool_name=Fire axe|tool_icon=surgery_tool_fire_axe}}{{Autowiki/SurgeryToolTemplate|tool_multiplier=2.5|tool_name=Butcher's cleaver|tool_icon=surgery_tool_butcher's_cleaver}}{{Autowiki/SurgeryToolTemplate|tool_multiplier=5|tool_name=Any sharp edged item with decent force|tool_icon=surgery_tool_any_sharp_edged_item_with_decent_force}}|icon=surgery_limbincise_skinthick|cstyle=}}{{Autowiki/SurgeryTemplate|name=Mend incision|description=Mend the incision in the patient's skin, closing it up. Clears most surgical states.|hard_requirements=<ul><li>Operate on patient</li><li>The patient must be lying down</li></ul>|soft_requirements=<ul><li>The bone must be sawed or drilled</li><li>The skin must be cut or opened</li><li>The blood vessels must be clamped or unclamped</li><li>The organs must be cut</li><li>The chest cavity must be opened wide</li></ul>|optional_requirements=|blocker_requirements=<ul><li>The operation site must not be obstructed by clothing</li><li>The patient must not be robotic</li><li>The patient must not have complex anatomy</li></ul>|tools={{Autowiki/SurgeryToolTemplate|tool_multiplier=1|tool_name=Cautery|tool_icon=surgery_tool_cautery}}{{Autowiki/SurgeryToolTemplate|tool_multiplier=1|tool_name=Suture|tool_icon=surgery_tool_suture}}{{Autowiki/SurgeryToolTemplate|tool_multiplier=1.15|tool_name=Type 5 laser gun|tool_icon=surgery_tool_type_5_laser_gun}}{{Autowiki/SurgeryToolTemplate|tool_multiplier=1.5|tool_name=Welder|tool_icon=surgery_tool_welder}}{{Autowiki/SurgeryToolTemplate|tool_multiplier=3.33|tool_name=Any heat source|tool_icon=surgery_tool_any_heat_source}}|icon=surgery_basicclose_skin|cstyle=}}{{Autowiki/SurgeryTemplate|name=Mend skin incision|description=Mend the incision in the patient's skin, closing it up. Clears most surgical states.|hard_requirements=<ul><li>The patient must be lying down</li><li>The limb must have skin</li><li>The skin must be cut or opened</li></ul>|soft_requirements=|optional_requirements=|blocker_requirements=<ul><li>The operation site must not be obstructed by clothing</li><li>The limb must not be cybernetic</li></ul>|tools={{Autowiki/SurgeryToolTemplate|tool_multiplier=1|tool_name=Cautery|tool_icon=surgery_tool_cautery}}{{Autowiki/SurgeryToolTemplate|tool_multiplier=1|tool_name=Suture|tool_icon=surgery_tool_suture}}{{Autowiki/SurgeryToolTemplate|tool_multiplier=1.15|tool_name=Type 5 laser gun|tool_icon=surgery_tool_type_5_laser_gun}}{{Autowiki/SurgeryToolTemplate|tool_multiplier=1.5|tool_name=Welder|tool_icon=surgery_tool_welder}}{{Autowiki/SurgeryToolTemplate|tool_multiplier=3.33|tool_name=Any heat source|tool_icon=surgery_tool_any_heat_source}}|icon=surgery_limbclose_skin|cstyle=}}{{Autowiki/SurgeryTemplate|name=Open hatch|description=Open the hatch of a mechanical patient to access its internals. Causes "skin open" and "vessels clamped" surgical states.|hard_requirements=<ul><li>The skin must be cut</li><li>The patient must be lying down</li></ul>|soft_requirements=|optional_requirements=<ul><li>A surgeon may perform this on themselves</li></ul>|blocker_requirements=<ul><li>The operation site must not be obstructed by clothing</li><li>The limb must not be organic</li></ul>|tools={{Autowiki/SurgeryToolTemplate|tool_multiplier=1|tool_name=Hands|tool_icon=surgery_tool_hands}}{{Autowiki/SurgeryToolTemplate|tool_multiplier=1|tool_name=Crowbar|tool_icon=surgery_tool_crowbar}}|icon=surgery_limbmechanical_open|cstyle=background-color: #44964A; color: #FFFFFF;}}{{Autowiki/SurgeryTemplate|name=Air Filtration Diagnostic (Lung Surgery)|description=Perform repairs to a patient's damaged lung by excising the most damaged lobe. This procedure can only be performed once per organ.|hard_requirements=<ul><li>Operate on lungs (target chest)</li><li>The skin must be open</li><li>The organs must be cut</li><li>The bone must be sawed</li><li>The patient must be lying down</li><li>The organ must be moderately damaged</li></ul>|soft_requirements=|optional_requirements=|blocker_requirements=<ul><li>The operation site must not be obstructed by clothing</li><li>The organ must not be organic</li><li>The organ must not have been surgically repaired prior</li></ul>|tools={{Autowiki/SurgeryToolTemplate|tool_multiplier=1.05|tool_name=Wrench|tool_icon=surgery_tool_wrench}}{{Autowiki/SurgeryToolTemplate|tool_multiplier=1.05|tool_name=Scalpel|tool_icon=surgery_tool_scalpel}}{{Autowiki/SurgeryToolTemplate|tool_multiplier=1.5|tool_name=Energy sword|tool_icon=surgery_tool_energy_sword}}{{Autowiki/SurgeryToolTemplate|tool_multiplier=2.25|tool_name=Knife|tool_icon=surgery_tool_knife}}{{Autowiki/SurgeryToolTemplate|tool_multiplier=2.85|tool_name=Shard|tool_icon=surgery_tool_shard}}|icon=surgery_organrepairlobectomymechanic|cstyle=background-color: #44964A; color: #FFFFFF;}}{{Autowiki/SurgeryTemplate|name=Impurity Management System Diagnostic (Liver Surgery)|description=Perform repairs to a patient's damaged liver by removing the most damaged section. This procedure can only be performed once per organ.|hard_requirements=<ul><li>Operate on liver (target chest)</li><li>The skin must be open</li><li>The organs must be cut</li><li>The bone must be sawed</li><li>The patient must be lying down</li><li>The organ must be moderately damaged</li></ul>|soft_requirements=|optional_requirements=|blocker_requirements=<ul><li>The operation site must not be obstructed by clothing</li><li>The organ must not be organic</li><li>The organ must not have been surgically repaired prior</li></ul>|tools={{Autowiki/SurgeryToolTemplate|tool_multiplier=1.05|tool_name=Wrench|tool_icon=surgery_tool_wrench}}{{Autowiki/SurgeryToolTemplate|tool_multiplier=1.05|tool_name=Scalpel|tool_icon=surgery_tool_scalpel}}{{Autowiki/SurgeryToolTemplate|tool_multiplier=1.5|tool_name=Energy sword|tool_icon=surgery_tool_energy_sword}}{{Autowiki/SurgeryToolTemplate|tool_multiplier=2.25|tool_name=Knife|tool_icon=surgery_tool_knife}}{{Autowiki/SurgeryToolTemplate|tool_multiplier=2.85|tool_name=Shard|tool_icon=surgery_tool_shard}}|icon=surgery_organrepairhepatectomymechanic|cstyle=background-color: #44964A; color: #FFFFFF;}}{{Autowiki/SurgeryTemplate|name=Nutrient Processing System Diagnostic (Stomach Surgery)|description=Perform repairs to a patient's stomach by removing a damaged section. This procedure can only be performed once per organ.|hard_requirements=<ul><li>Operate on stomach (target chest)</li><li>The skin must be open</li><li>The organs must be cut</li><li>The bone must be sawed</li><li>The patient must be lying down</li><li>The organ must be moderately damaged</li></ul>|soft_requirements=|optional_requirements=|blocker_requirements=<ul><li>The operation site must not be obstructed by clothing</li><li>The organ must not be organic</li><li>The organ must not have been surgically repaired prior</li></ul>|tools={{Autowiki/SurgeryToolTemplate|tool_multiplier=1.05|tool_name=Wrench|tool_icon=surgery_tool_wrench}}{{Autowiki/SurgeryToolTemplate|tool_multiplier=1.05|tool_name=Scalpel|tool_icon=surgery_tool_scalpel}}{{Autowiki/SurgeryToolTemplate|tool_multiplier=1.5|tool_name=Energy sword|tool_icon=surgery_tool_energy_sword}}{{Autowiki/SurgeryToolTemplate|tool_multiplier=2.25|tool_name=Knife|tool_icon=surgery_tool_knife}}{{Autowiki/SurgeryToolTemplate|tool_multiplier=2.85|tool_name=Shard|tool_icon=surgery_tool_shard}}{{Autowiki/SurgeryToolTemplate|tool_multiplier=4|tool_name=Any sharp edged item|tool_icon=surgery_tool_any_sharp_edged_item}}|icon=surgery_organrepairgastrectomymechanic|cstyle=background-color: #44964A; color: #FFFFFF;}}{{Autowiki/SurgeryTemplate|name=Wetware OS Diagnostics (Brain Surgery)|description=Repair a patient's damaged brain tissue to restore cognitive function.|hard_requirements=<ul><li>Operate on brain (target head)</li><li>The skin must be open</li><li>The bone must be sawed</li><li>The patient must be lying down</li></ul>|soft_requirements=|optional_requirements=|blocker_requirements=<ul><li>The blood vessels must not be unclamped</li><li>The operation site must not be obstructed by clothing</li><li>The organ must not be organic</li></ul>|tools={{Autowiki/SurgeryToolTemplate|tool_multiplier=1.15|tool_name=Multitool|tool_icon=surgery_tool_multitool}}{{Autowiki/SurgeryToolTemplate|tool_multiplier=1.05|tool_name=Hemostat|tool_icon=surgery_tool_hemostat}}{{Autowiki/SurgeryToolTemplate|tool_multiplier=2.85|tool_name=Screwdriver|tool_icon=surgery_tool_screwdriver}}{{Autowiki/SurgeryToolTemplate|tool_multiplier=6.67|tool_name=Pen|tool_icon=surgery_tool_pen}}|icon=surgery_organrepairbrainmechanic|cstyle=background-color: #44964A; color: #FFFFFF;}}{{Autowiki/SurgeryTemplate|name=Plastic surgery|description=Reshape or reconstruct a patient's face for cosmetic or functional purposes.|hard_requirements=<ul><li>Operate on head (target head)</li><li>The skin must be open</li><li>The patient must be lying down</li></ul>|soft_requirements=|optional_requirements=|blocker_requirements=<ul><li>The operation site must not be obstructed by clothing</li></ul>|tools={{Autowiki/SurgeryToolTemplate|tool_multiplier=1|tool_name=Scalpel|tool_icon=surgery_tool_scalpel}}{{Autowiki/SurgeryToolTemplate|tool_multiplier=2|tool_name=Knife|tool_icon=surgery_tool_knife}}{{Autowiki/SurgeryToolTemplate|tool_multiplier=2.85|tool_name=Cutters|tool_icon=surgery_tool_cutters}}{{Autowiki/SurgeryToolTemplate|tool_multiplier=5|tool_name=Pen|tool_icon=surgery_tool_pen}}|icon=surgery_limbplastic_surgery|cstyle=}}{{Autowiki/SurgeryTemplate|name=Prepare electronics|description=Prepare the internal electronics of a mechanical patient for surgery. Causes "organs cut" surgical state.|hard_requirements=<ul><li>The skin must be open</li><li>The patient must be lying down</li></ul>|soft_requirements=|optional_requirements=<ul><li>A surgeon may perform this on themselves</li></ul>|blocker_requirements=<ul><li>The organs must not be cut</li><li>The operation site must not be obstructed by clothing</li><li>The limb must not be organic</li></ul>|tools={{Autowiki/SurgeryToolTemplate|tool_multiplier=1|tool_name=Multitool|tool_icon=surgery_tool_multitool}}{{Autowiki/SurgeryToolTemplate|tool_multiplier=1.33|tool_name=Hemostat|tool_icon=surgery_tool_hemostat}}|icon=surgery_limbprepare_electronics|cstyle=background-color: #44964A; color: #FFFFFF;}}{{Autowiki/SurgeryTemplate|name=Prosthetic feature manipulation|description=Manipulate features of the patient, such as a moth's wings or a lizard's tail.|hard_requirements=<ul><li>The skin must be open</li><li>The bone must be sawed</li><li>The patient must be lying down</li></ul>|soft_requirements=|optional_requirements=<ul><li>A surgeon may perform this on themselves</li></ul>|blocker_requirements=<ul><li>The blood vessels must not be unclamped</li><li>The operation site must not be obstructed by clothing</li><li>The limb must not be organic</li></ul>|tools={{Autowiki/SurgeryToolTemplate|tool_multiplier=1|tool_name=Crowbar|tool_icon=surgery_tool_crowbar}}{{Autowiki/SurgeryToolTemplate|tool_multiplier=1|tool_name=Hemostat|tool_icon=surgery_tool_hemostat}}{{Autowiki/SurgeryToolTemplate|tool_multiplier=2.85|tool_name=Fork|tool_icon=surgery_tool_fork}}{{Autowiki/SurgeryToolTemplate|tool_multiplier=1|tool_name=Organ|tool_icon=surgery_tool_organ}}|icon=surgery_limborgan_manipulationexternalmechanic|cstyle=}}{{Autowiki/SurgeryTemplate|name=Prosthetic organ manipulation|description=Manipulate a patient's internal organs.|hard_requirements=<ul><li>The skin must be open</li><li>The organs must be cut</li><li>The patient must be lying down</li></ul>|soft_requirements=<ul><li>If operating on the brain or any chest organs, the bone MUST be sawed</li><li>Otherwise, the state of the bone doesn't matter</li></ul>|optional_requirements=<ul><li>A surgeon may perform this on themselves</li></ul>|blocker_requirements=<ul><li>The operation site must not be obstructed by clothing</li><li>The limb must not be organic</li></ul>|tools={{Autowiki/SurgeryToolTemplate|tool_multiplier=1|tool_name=Crowbar|tool_icon=surgery_tool_crowbar}}{{Autowiki/SurgeryToolTemplate|tool_multiplier=1|tool_name=Hemostat|tool_icon=surgery_tool_hemostat}}{{Autowiki/SurgeryToolTemplate|tool_multiplier=2.85|tool_name=Fork|tool_icon=surgery_tool_fork}}{{Autowiki/SurgeryToolTemplate|tool_multiplier=1|tool_name=Organ|tool_icon=surgery_tool_organ}}|icon=surgery_limborgan_manipulationinternalmechanic|cstyle=background-color: #44964A; color: #FFFFFF;}}{{Autowiki/SurgeryTemplate|name=Prosthetic replacement|description=Replace a missing limb with a prosthetic (or arbitrary) item.|hard_requirements=<ul><li>Operate on chest (target chest)</li><li>The skin must be open</li><li>When the chest is prepared, target the zone of the limb you are attaching</li><li>Arms may receive any suitable item in lieu of a replacement limb</li></ul>|soft_requirements=|optional_requirements=|blocker_requirements=<ul><li>The blood vessels must not be unclamped</li></ul>|tools={{Autowiki/SurgeryToolTemplate|tool_multiplier=1|tool_name=Limb|tool_icon=surgery_tool_limb}}{{Autowiki/SurgeryToolTemplate|tool_multiplier=1|tool_name=Any suitable arm replacement|tool_icon=surgery_tool_any_suitable_arm_replacement}}|icon=surgery_prosthetic_replacement|cstyle=}}{{Autowiki/SurgeryTemplate|name=Gastric Lavage (Stomach Pump)|description=Manually pump a patient's stomach to induce vomiting and expel harmful chemicals.|hard_requirements=<ul><li>Operate on stomach (target chest)</li><li>The skin must be open</li><li>The organs must be cut</li><li>The patient must be lying down</li><li>The patient must not be husked</li></ul>|soft_requirements=|optional_requirements=|blocker_requirements=<ul><li>The operation site must not be obstructed by clothing</li><li>The organ must not be cybernetic</li></ul>|tools={{Autowiki/SurgeryToolTemplate|tool_multiplier=1|tool_name=Hands|tool_icon=surgery_tool_hands}}|icon=surgery_organstomach_pump|cstyle=}}{{Autowiki/SurgeryTemplate|name=Hydraulics Purge (Blood Filtration)|description=Remove unwanted chemicals from a patient's bloodstream.|hard_requirements=<ul><li>Operate on chest (target chest)</li><li>The skin must be open</li><li>The patient must be lying down</li><li>The patient must not be husked</li></ul>|soft_requirements=|optional_requirements=|blocker_requirements=<ul><li>The blood vessels must not be unclamped</li><li>The operation site must not be obstructed by clothing</li><li>The limb must not be organic</li></ul>|tools={{Autowiki/SurgeryToolTemplate|tool_multiplier=1|tool_name=Blood filter|tool_icon=surgery_tool_blood_filter}}|icon=surgery_limbfilter_bloodmechanic|cstyle=background-color: #44964A; color: #FFFFFF;}}{{Autowiki/SurgeryTemplate|name=Nutrient Processor Purge (Stomach Pump)|description=Manually pump a patient's stomach to induce vomiting and expel harmful chemicals.|hard_requirements=<ul><li>Operate on stomach (target chest)</li><li>The skin must be open</li><li>The organs must be cut</li><li>The patient must be lying down</li><li>The patient must not be husked</li></ul>|soft_requirements=|optional_requirements=|blocker_requirements=<ul><li>The operation site must not be obstructed by clothing</li><li>The organ must not be organic</li></ul>|tools={{Autowiki/SurgeryToolTemplate|tool_multiplier=1|tool_name=Hands|tool_icon=surgery_tool_hands}}|icon=surgery_organstomach_pumpmechanic|cstyle=background-color: #44964A; color: #FFFFFF;}}{{Autowiki/SurgeryTemplate|name=Realign blood vessels|description=Realign a patient's torn blood vessels to prepare for sealing.|hard_requirements=<ul><li>The limb must have an unoperated puncture wound</li><li>The skin must be open</li><li>The organs must be cut</li><li>The patient must be lying down</li></ul>|soft_requirements=|optional_requirements=|blocker_requirements=<ul><li>The operation site must not be obstructed by clothing</li></ul>|tools={{Autowiki/SurgeryToolTemplate|tool_multiplier=1|tool_name=Hemostat|tool_icon=surgery_tool_hemostat}}{{Autowiki/SurgeryToolTemplate|tool_multiplier=1.15|tool_name=Scalpel|tool_icon=surgery_tool_scalpel}}{{Autowiki/SurgeryToolTemplate|tool_multiplier=2.5|tool_name=Cutters|tool_icon=surgery_tool_cutters}}|icon=surgery_limbrepair_puncture|cstyle=}}{{Autowiki/SurgeryTemplate|name=Remove cavity implant|description=Remove an item from a body cavity.|hard_requirements=<ul><li>Operate on chest (target chest)</li><li>The skin must be open</li><li>The organs must be cut</li><li>The chest cavity must be opened wide</li><li>The patient must be lying down</li></ul>|soft_requirements=|optional_requirements=|blocker_requirements=<ul><li>The operation site must not be obstructed by clothing</li></ul>|tools={{Autowiki/SurgeryToolTemplate|tool_multiplier=1|tool_name=Hands|tool_icon=surgery_tool_hands}}{{Autowiki/SurgeryToolTemplate|tool_multiplier=2|tool_name=Hemostat|tool_icon=surgery_tool_hemostat}}{{Autowiki/SurgeryToolTemplate|tool_multiplier=2.5|tool_name=Crowbar|tool_icon=surgery_tool_crowbar}}{{Autowiki/SurgeryToolTemplate|tool_multiplier=5|tool_name=Fork|tool_icon=surgery_tool_fork}}|icon=surgery_limbundo_cavity_implant|cstyle=}}{{Autowiki/SurgeryTemplate|name=Hepatectomy (Liver Surgery)|description=Perform repairs to a patient's damaged liver by removing the most damaged section. This procedure can only be performed once per organ.|hard_requirements=<ul><li>Operate on liver (target chest)</li><li>The skin must be open</li><li>The organs must be cut</li><li>The bone must be sawed</li><li>The patient must be lying down</li><li>The organ must be moderately damaged</li></ul>|soft_requirements=|optional_requirements=|blocker_requirements=<ul><li>The operation site must not be obstructed by clothing</li><li>The organ must not be cybernetic</li><li>The organ must not have been surgically repaired prior</li></ul>|tools={{Autowiki/SurgeryToolTemplate|tool_multiplier=1.05|tool_name=Scalpel|tool_icon=surgery_tool_scalpel}}{{Autowiki/SurgeryToolTemplate|tool_multiplier=1.5|tool_name=Energy sword|tool_icon=surgery_tool_energy_sword}}{{Autowiki/SurgeryToolTemplate|tool_multiplier=2.25|tool_name=Knife|tool_icon=surgery_tool_knife}}{{Autowiki/SurgeryToolTemplate|tool_multiplier=2.85|tool_name=Shard|tool_icon=surgery_tool_shard}}|icon=surgery_organrepairhepatectomy|cstyle=}}{{Autowiki/SurgeryTemplate|name=Gastrectomy (Stomach Surgery)|description=Perform repairs to a patient's stomach by removing a damaged section. This procedure can only be performed once per organ.|hard_requirements=<ul><li>Operate on stomach (target chest)</li><li>The skin must be open</li><li>The organs must be cut</li><li>The bone must be sawed</li><li>The patient must be lying down</li><li>The organ must be moderately damaged</li></ul>|soft_requirements=|optional_requirements=|blocker_requirements=<ul><li>The operation site must not be obstructed by clothing</li><li>The organ must not be cybernetic</li><li>The organ must not have been surgically repaired prior</li></ul>|tools={{Autowiki/SurgeryToolTemplate|tool_multiplier=1.05|tool_name=Scalpel|tool_icon=surgery_tool_scalpel}}{{Autowiki/SurgeryToolTemplate|tool_multiplier=1.5|tool_name=Energy sword|tool_icon=surgery_tool_energy_sword}}{{Autowiki/SurgeryToolTemplate|tool_multiplier=2.25|tool_name=Knife|tool_icon=surgery_tool_knife}}{{Autowiki/SurgeryToolTemplate|tool_multiplier=2.85|tool_name=Shard|tool_icon=surgery_tool_shard}}{{Autowiki/SurgeryToolTemplate|tool_multiplier=4|tool_name=Any sharp edged item|tool_icon=surgery_tool_any_sharp_edged_item}}|icon=surgery_organrepairgastrectomy|cstyle=}}{{Autowiki/SurgeryTemplate|name=Remove dental implant|description=Remove a dental implant from a patient's teeth.|hard_requirements=<ul><li>The skin must be open</li><li>The bone must be drilled</li><li>The patient must be lying down</li></ul>|soft_requirements=|optional_requirements=|blocker_requirements=<ul><li>The blood vessels must not be unclamped</li><li>The operation site must not be obstructed by clothing</li></ul>|tools={{Autowiki/SurgeryToolTemplate|tool_multiplier=1|tool_name=Hemostat|tool_icon=surgery_tool_hemostat}}{{Autowiki/SurgeryToolTemplate|tool_multiplier=1|tool_name=Hands|tool_icon=surgery_tool_hands}}|icon=surgery_limbremove_dental_implant|cstyle=}}{{Autowiki/SurgeryTemplate|name=Repair compound fracture|description=Mend a compound fracture in a patient's bone.|hard_requirements=<ul><li>The limb's compound fracture has been reset</li><li>The patient must be lying down</li><li>The skin must be cut or opened</li></ul>|soft_requirements=|optional_requirements=|blocker_requirements=<ul><li>The operation site must not be obstructed by clothing</li></ul>|tools={{Autowiki/SurgeryToolTemplate|tool_multiplier=1|tool_name=Bone gel|tool_icon=surgery_tool_bone_gel}}{{Autowiki/SurgeryToolTemplate|tool_multiplier=1|tool_name=Surgical tape|tool_icon=surgery_tool_surgical_tape}}{{Autowiki/SurgeryToolTemplate|tool_multiplier=2|tool_name=Super sticky tape|tool_icon=surgery_tool_super_sticky_tape}}{{Autowiki/SurgeryToolTemplate|tool_multiplier=3.33|tool_name=Sticky tape|tool_icon=surgery_tool_sticky_tape}}|icon=surgery_limbrepair_compound|cstyle=}}{{Autowiki/SurgeryTemplate|name=Repair cranium|description=Mend a cranial fissure in a patient's skull.|hard_requirements=<ul><li>The debris has been cleared from the cranial fissure</li><li>The patient must be lying down</li></ul>|soft_requirements=|optional_requirements=|blocker_requirements=<ul><li>The operation site must not be obstructed by clothing</li></ul>|tools={{Autowiki/SurgeryToolTemplate|tool_multiplier=1|tool_name=Bone gel|tool_icon=surgery_tool_bone_gel}}{{Autowiki/SurgeryToolTemplate|tool_multiplier=1|tool_name=Surgical tape|tool_icon=surgery_tool_surgical_tape}}{{Autowiki/SurgeryToolTemplate|tool_multiplier=2|tool_name=Super sticky tape|tool_icon=surgery_tool_super_sticky_tape}}{{Autowiki/SurgeryToolTemplate|tool_multiplier=3.33|tool_name=Sticky tape|tool_icon=surgery_tool_sticky_tape}}|icon=surgery_limbrepair_cranium|cstyle=}}{{Autowiki/SurgeryTemplate|name=Repair hairline fracture|description=Mend a hairline fracture in a patient's bone.|hard_requirements=<ul><li>The limb must have a hairline fracture</li><li>The patient must be lying down</li><li>The skin must be cut or opened</li></ul>|soft_requirements=|optional_requirements=|blocker_requirements=<ul><li>The operation site must not be obstructed by clothing</li></ul>|tools={{Autowiki/SurgeryToolTemplate|tool_multiplier=1|tool_name=Bonesetter|tool_icon=surgery_tool_bonesetter}}{{Autowiki/SurgeryToolTemplate|tool_multiplier=1|tool_name=Bone gel|tool_icon=surgery_tool_bone_gel}}{{Autowiki/SurgeryToolTemplate|tool_multiplier=1|tool_name=Surgical tape|tool_icon=surgery_tool_surgical_tape}}{{Autowiki/SurgeryToolTemplate|tool_multiplier=2|tool_name=Super sticky tape|tool_icon=surgery_tool_super_sticky_tape}}{{Autowiki/SurgeryToolTemplate|tool_multiplier=3.33|tool_name=Sticky tape|tool_icon=surgery_tool_sticky_tape}}|icon=surgery_limbrepair_hairline|cstyle=}}{{Autowiki/SurgeryTemplate|name=Reset compound fracture|description=Reset a compound fracture in a patient's bone, preparing it for proper healing.|hard_requirements=<ul><li>The limb must have a compound fracture</li><li>The skin must be open</li><li>The patient must be lying down</li></ul>|soft_requirements=|optional_requirements=|blocker_requirements=<ul><li>The blood vessels must not be unclamped</li><li>The operation site must not be obstructed by clothing</li></ul>|tools={{Autowiki/SurgeryToolTemplate|tool_multiplier=1|tool_name=Bonesetter|tool_icon=surgery_tool_bonesetter}}{{Autowiki/SurgeryToolTemplate|tool_multiplier=1.66|tool_name=Surgical tape|tool_icon=surgery_tool_surgical_tape}}{{Autowiki/SurgeryToolTemplate|tool_multiplier=2.5|tool_name=Super sticky tape|tool_icon=surgery_tool_super_sticky_tape}}{{Autowiki/SurgeryToolTemplate|tool_multiplier=5|tool_name=Sticky tape|tool_icon=surgery_tool_sticky_tape}}|icon=surgery_limbreset_compound|cstyle=}}{{Autowiki/SurgeryTemplate|name=Reset dislocation|description=Reset a dislocated bone in a patient's limb. Similar to the field procedure, but quicker and safer due to being performed in a controlled environment.|hard_requirements=<ul><li>The limb must be dislocated</li></ul>|soft_requirements=|optional_requirements=|blocker_requirements=<ul><li>The operation site must not be obstructed by clothing</li></ul>|tools={{Autowiki/SurgeryToolTemplate|tool_multiplier=1|tool_name=Bonesetter|tool_icon=surgery_tool_bonesetter}}{{Autowiki/SurgeryToolTemplate|tool_multiplier=2|tool_name=Crowbar|tool_icon=surgery_tool_crowbar}}{{Autowiki/SurgeryToolTemplate|tool_multiplier=5|tool_name=Hands|tool_icon=surgery_tool_hands}}|icon=surgery_limbrepair_dislocation|cstyle=}}{{Autowiki/SurgeryTemplate|name=Retract skin|description=Retract the patient's skin to access their internal organs. Causes "skin open" surgical state.|hard_requirements=<ul><li>The skin must be cut</li><li>The patient must be lying down</li></ul>|soft_requirements=|optional_requirements=|blocker_requirements=<ul><li>The operation site must not be obstructed by clothing</li><li>The limb must not be cybernetic</li></ul>|tools={{Autowiki/SurgeryToolTemplate|tool_multiplier=1|tool_name=Retractor|tool_icon=surgery_tool_retractor}}{{Autowiki/SurgeryToolTemplate|tool_multiplier=2.25|tool_name=Screwdriver|tool_icon=surgery_tool_screwdriver}}{{Autowiki/SurgeryToolTemplate|tool_multiplier=2.85|tool_name=Cutters|tool_icon=surgery_tool_cutters}}{{Autowiki/SurgeryToolTemplate|tool_multiplier=2.85|tool_name=Iron rod|tool_icon=surgery_tool_iron_rod}}{{Autowiki/SurgeryToolTemplate|tool_multiplier=2.85|tool_name=Fork|tool_icon=surgery_tool_fork}}|icon=surgery_limbretract_skin|cstyle=}}{{Autowiki/SurgeryTemplate|name=Saw bone|description=Saw through the patient's bones to access their internal organs. Causes "bone sawed" surgical state.|hard_requirements=<ul><li>Operate on patient</li><li>The skin must be open</li><li>The patient must be lying down</li></ul>|soft_requirements=|optional_requirements=|blocker_requirements=<ul><li>The bone must be intact</li><li>The operation site must not be obstructed by clothing</li><li>The patient must not be robotic</li><li>The patient must not have complex anatomy</li></ul>|tools={{Autowiki/SurgeryToolTemplate|tool_multiplier=1|tool_name=Saw|tool_icon=surgery_tool_saw}}{{Autowiki/SurgeryToolTemplate|tool_multiplier=1.33|tool_name=Serrated bone shovel|tool_icon=surgery_tool_serrated_bone_shovel}}{{Autowiki/SurgeryToolTemplate|tool_multiplier=1.33|tool_name=Arm blade|tool_icon=surgery_tool_arm_blade}}{{Autowiki/SurgeryToolTemplate|tool_multiplier=2|tool_name=Fire axe|tool_icon=surgery_tool_fire_axe}}{{Autowiki/SurgeryToolTemplate|tool_multiplier=2.85|tool_name=Hatchet|tool_icon=surgery_tool_hatchet}}{{Autowiki/SurgeryToolTemplate|tool_multiplier=2.85|tool_name=Butcher's cleaver|tool_icon=surgery_tool_butcher's_cleaver}}{{Autowiki/SurgeryToolTemplate|tool_multiplier=4|tool_name=Any sharp edged item with decent force|tool_icon=surgery_tool_any_sharp_edged_item_with_decent_force}}|icon=surgery_basicsaw_bone|cstyle=}}{{Autowiki/SurgeryTemplate|name=Saw limb bone|description=Saw through the patient's bones to access their internal organs. Causes "bone sawed" surgical state.|hard_requirements=<ul><li>The skin must be open</li><li>The patient must be lying down</li></ul>|soft_requirements=|optional_requirements=|blocker_requirements=<ul><li>The bone must be intact</li><li>The operation site must not be obstructed by clothing</li><li>The limb must not be cybernetic</li></ul>|tools={{Autowiki/SurgeryToolTemplate|tool_multiplier=1|tool_name=Saw|tool_icon=surgery_tool_saw}}{{Autowiki/SurgeryToolTemplate|tool_multiplier=1.33|tool_name=Serrated bone shovel|tool_icon=surgery_tool_serrated_bone_shovel}}{{Autowiki/SurgeryToolTemplate|tool_multiplier=1.33|tool_name=Arm blade|tool_icon=surgery_tool_arm_blade}}{{Autowiki/SurgeryToolTemplate|tool_multiplier=2|tool_name=Fire axe|tool_icon=surgery_tool_fire_axe}}{{Autowiki/SurgeryToolTemplate|tool_multiplier=2.85|tool_name=Hatchet|tool_icon=surgery_tool_hatchet}}{{Autowiki/SurgeryToolTemplate|tool_multiplier=2.85|tool_name=Butcher's cleaver|tool_icon=surgery_tool_butcher's_cleaver}}{{Autowiki/SurgeryToolTemplate|tool_multiplier=4|tool_name=Any sharp edged item with decent force|tool_icon=surgery_tool_any_sharp_edged_item_with_decent_force}}|icon=surgery_limbsaw_bones|cstyle=}}{{Autowiki/SurgeryTemplate|name=Screw shell|description=Screw the shell of a mechanical patient back into place. Clears most surgical states.|hard_requirements=<ul><li>The patient must be lying down</li><li>The skin must be cut or opened</li></ul>|soft_requirements=|optional_requirements=<ul><li>A surgeon may perform this on themselves</li></ul>|blocker_requirements=<ul><li>The operation site must not be obstructed by clothing</li><li>The limb must not be organic</li></ul>|tools={{Autowiki/SurgeryToolTemplate|tool_multiplier=1|tool_name=Screwdriver|tool_icon=surgery_tool_screwdriver}}{{Autowiki/SurgeryToolTemplate|tool_multiplier=1.33|tool_name=Scalpel|tool_icon=surgery_tool_scalpel}}{{Autowiki/SurgeryToolTemplate|tool_multiplier=2|tool_name=Knife|tool_icon=surgery_tool_knife}}{{Autowiki/SurgeryToolTemplate|tool_multiplier=10|tool_name=Any sharp item|tool_icon=surgery_tool_any_sharp_item}}|icon=surgery_limbmechanical_close|cstyle=background-color: #44964A; color: #FFFFFF;}}{{Autowiki/SurgeryTemplate|name=Seal blood vessels|description=Seal a patient's now-realigned blood vessels.|hard_requirements=<ul><li>The limb must have an operated puncture wound</li><li>The skin must be open</li><li>The organs must be cut</li><li>The patient must be lying down</li></ul>|soft_requirements=|optional_requirements=|blocker_requirements=<ul><li>The operation site must not be obstructed by clothing</li></ul>|tools={{Autowiki/SurgeryToolTemplate|tool_multiplier=1|tool_name=Cautery|tool_icon=surgery_tool_cautery}}{{Autowiki/SurgeryToolTemplate|tool_multiplier=1.12|tool_name=Type 5 laser gun|tool_icon=surgery_tool_type_5_laser_gun}}{{Autowiki/SurgeryToolTemplate|tool_multiplier=1.5|tool_name=Welder|tool_icon=surgery_tool_welder}}{{Autowiki/SurgeryToolTemplate|tool_multiplier=3.33|tool_name=Any heat source|tool_icon=surgery_tool_any_heat_source}}|icon=surgery_limbseal_veins|cstyle=}}{{Autowiki/SurgeryTemplate|name=Secure prosthetic|description=Ensure that an arbitrary prosthetic is properly attached to a patient's body.|hard_requirements=<ul><li>The prosthetic must be unsecured</li></ul>|soft_requirements=|optional_requirements=<ul><li>A surgeon may perform this on themselves</li></ul>|blocker_requirements=<ul><li>The operation site must not be obstructed by clothing</li></ul>|tools={{Autowiki/SurgeryToolTemplate|tool_multiplier=1|tool_name=Suture|tool_icon=surgery_tool_suture}}{{Autowiki/SurgeryToolTemplate|tool_multiplier=1.25|tool_name=Surgical tape|tool_icon=surgery_tool_surgical_tape}}{{Autowiki/SurgeryToolTemplate|tool_multiplier=2|tool_name=Sticky tape|tool_icon=surgery_tool_sticky_tape}}|icon=surgery_limbsecure_arbitrary_prosthetic|cstyle=}}{{Autowiki/SurgeryTemplate|name=Brain Defibrillation (Revival)|description=Use a defibrillator to shock a patient's brain back to life.|hard_requirements=<ul><li>Operate on head (target head)</li><li>The skin must be open</li><li>The bone must be sawed</li><li>The patient must be lying down</li><li>The patient must be deceased</li><li>The patient must be in a revivable state</li></ul>|soft_requirements=|optional_requirements=|blocker_requirements=<ul><li>The operation site must not be obstructed by clothing</li></ul>|tools={{Autowiki/SurgeryToolTemplate|tool_multiplier=1|tool_name=Defibrillator paddles|tool_icon=surgery_tool_defibrillator_paddles}}{{Autowiki/SurgeryToolTemplate|tool_multiplier=1|tool_name=Shock touch|tool_icon=surgery_tool_shock_touch}}{{Autowiki/SurgeryToolTemplate|tool_multiplier=1.33|tool_name=Stun baton|tool_icon=surgery_tool_stun_baton}}{{Autowiki/SurgeryToolTemplate|tool_multiplier=1.67|tool_name=Energy gun|tool_icon=surgery_tool_energy_gun}}|icon=surgery_basicrevival|cstyle=}}{{Autowiki/SurgeryTemplate|name=System Failure Analysis (Dissection and Autopsy)|description=Perform a detailed analysis of a robotic patient's deactivated systems.|hard_requirements=<ul><li>Operate on chest (target chest)</li><li>The skin must be open</li><li>The patient must be lying down</li><li>The patient must be deceased</li><li>The patient must not have been autopsied prior</li></ul>|soft_requirements=|optional_requirements=|blocker_requirements=<ul><li>The limb must not be organic</li></ul>|tools={{Autowiki/SurgeryToolTemplate|tool_multiplier=1|tool_name=Autopsy scanner|tool_icon=surgery_tool_autopsy_scanner}}|icon=surgery_limbautopsymechanic|cstyle=background-color: #44964A; color: #FFFFFF;}}{{Autowiki/SurgeryTemplate|name=Tend Wounds|description=Perform superficial wound care on a patient's bruises and burns.|hard_requirements=<ul><li>Operate on chest (target chest)</li><li>The patient must be lying down</li><li>The patient must have brute or burn damage</li><li>The skin must be cut or opened</li></ul>|soft_requirements=|optional_requirements=|blocker_requirements=<ul><li>The patient must not be robotic</li></ul>|tools={{Autowiki/SurgeryToolTemplate|tool_multiplier=1|tool_name=Hemostat|tool_icon=surgery_tool_hemostat}}{{Autowiki/SurgeryToolTemplate|tool_multiplier=1.5|tool_name=Screwdriver|tool_icon=surgery_tool_screwdriver}}{{Autowiki/SurgeryToolTemplate|tool_multiplier=1.67|tool_name=Cutters|tool_icon=surgery_tool_cutters}}{{Autowiki/SurgeryToolTemplate|tool_multiplier=1.8|tool_name=Pen|tool_icon=surgery_tool_pen}}|icon=surgery_basictend_wounds|cstyle=}}{{Autowiki/SurgeryTemplate|name=Unclamp bleeders|description=Unclamp blood vessels in the patient's body to allow blood flow again. Clears "vessels clamped" surgical state.|hard_requirements=<ul><li>The skin must be open</li><li>The blood vessels must be clamped</li><li>The patient must be lying down</li><li>The limb must have blood vessels</li></ul>|soft_requirements=|optional_requirements=|blocker_requirements=<ul><li>The operation site must not be obstructed by clothing</li><li>The limb must not be cybernetic</li></ul>|tools={{Autowiki/SurgeryToolTemplate|tool_multiplier=1|tool_name=Hemostat|tool_icon=surgery_tool_hemostat}}{{Autowiki/SurgeryToolTemplate|tool_multiplier=1.67|tool_name=Cutters|tool_icon=surgery_tool_cutters}}{{Autowiki/SurgeryToolTemplate|tool_multiplier=2.85|tool_name=Package wrapper|tool_icon=surgery_tool_package_wrapper}}{{Autowiki/SurgeryToolTemplate|tool_multiplier=6.67|tool_name=Cable coil|tool_icon=surgery_tool_cable_coil}}|icon=surgery_limbunclamp_bleeders|cstyle=}}{{Autowiki/SurgeryTemplate|name=Unscrew shell|description=Unscrew the shell of a mechanical patient to access its internals. Causes "cut skin" surgical state.|hard_requirements=<ul><li>The patient must be lying down</li></ul>|soft_requirements=|optional_requirements=<ul><li>A surgeon may perform this on themselves</li></ul>|blocker_requirements=<ul><li>The skin must be intact</li><li>The operation site must not be obstructed by clothing</li><li>The limb must not be organic</li></ul>|tools={{Autowiki/SurgeryToolTemplate|tool_multiplier=1|tool_name=Screwdriver|tool_icon=surgery_tool_screwdriver}}{{Autowiki/SurgeryToolTemplate|tool_multiplier=1.33|tool_name=Scalpel|tool_icon=surgery_tool_scalpel}}{{Autowiki/SurgeryToolTemplate|tool_multiplier=2|tool_name=Knife|tool_icon=surgery_tool_knife}}{{Autowiki/SurgeryToolTemplate|tool_multiplier=10|tool_name=Any sharp item|tool_icon=surgery_tool_any_sharp_item}}|icon=surgery_limbmechanical_incision|cstyle=background-color: #44964A; color: #FFFFFF;}}{{Autowiki/SurgeryTemplate|name=Unwrench endoskeleton|description=Unwrench a mechanical patient's endoskeleton to access its internals. Clears "bone sawed" surgical state.|hard_requirements=<ul><li>The skin must be open</li><li>The patient must be lying down</li></ul>|soft_requirements=|optional_requirements=<ul><li>A surgeon may perform this on themselves</li></ul>|blocker_requirements=<ul><li>The bone must be intact</li><li>The operation site must not be obstructed by clothing</li><li>The limb must not be organic</li></ul>|tools={{Autowiki/SurgeryToolTemplate|tool_multiplier=1|tool_name=Wrench|tool_icon=surgery_tool_wrench}}{{Autowiki/SurgeryToolTemplate|tool_multiplier=1.33|tool_name=Retractor|tool_icon=surgery_tool_retractor}}|icon=surgery_limbmechanic_unwrench|cstyle=background-color: #44964A; color: #FFFFFF;}}{{Autowiki/SurgeryTemplate|name=Widen chest cavity|description=Widen a patient's chest cavity to allow for implanting of larger items.|hard_requirements=<ul><li>Operate on chest (target chest)</li><li>The skin must be open</li><li>The organs must be cut</li><li>The patient must be lying down</li></ul>|soft_requirements=|optional_requirements=|blocker_requirements=<ul><li>The chest cavity must not be opened wide</li><li>The operation site must not be obstructed by clothing</li></ul>|tools={{Autowiki/SurgeryToolTemplate|tool_multiplier=1|tool_name=Retractor|tool_icon=surgery_tool_retractor}}{{Autowiki/SurgeryToolTemplate|tool_multiplier=1.5|tool_name=Crowbar|tool_icon=surgery_tool_crowbar}}|icon=surgery_limbprepare_cavity|cstyle=}}{{Autowiki/SurgeryTemplate|name=Wrench endoskeleton|description=Wrench a mechanical patient's endoskeleton back into place. Clears "bone sawed" surgical state.|hard_requirements=<ul><li>The skin must be open</li><li>The bone must be sawed</li><li>The patient must be lying down</li><li>The limb must have bones</li></ul>|soft_requirements=|optional_requirements=<ul><li>A surgeon may perform this on themselves</li></ul>|blocker_requirements=<ul><li>The operation site must not be obstructed by clothing</li><li>The limb must not be organic</li></ul>|tools={{Autowiki/SurgeryToolTemplate|tool_multiplier=1|tool_name=Wrench|tool_icon=surgery_tool_wrench}}{{Autowiki/SurgeryToolTemplate|tool_multiplier=1.33|tool_name=Retractor|tool_icon=surgery_tool_retractor}}|icon=surgery_limbmechanic_wrench|cstyle=background-color: #44964A; color: #FFFFFF;}}{{Autowiki/SurgeryTemplate|name=Apply plastic|description=Apply plastic to a patient's face to to allow for greater customization in following plastic surgery.|hard_requirements=<ul><li>The skin must be open</li><li>The patient must be lying down</li></ul>|soft_requirements=|optional_requirements=|blocker_requirements=<ul><li>The blood vessels must not be unclamped</li><li>Plastic must not be applied</li><li>The operation site must not be obstructed by clothing</li></ul>|tools={{Autowiki/SurgeryToolTemplate|tool_multiplier=1|tool_name=Plastic|tool_icon=surgery_tool_plastic}}|icon=surgery_limbadd_plastic|cstyle=background-color: #53277E; color: #FFFFFF;}}{{Autowiki/SurgeryTemplate|name=Neural Brainwashing (Brainwash)|description=A surgical procedure which directly implants a directive into the patient's brain, making it their absolute priority. It can be cleared using a mindshield implant.|hard_requirements=<ul><li>Operate on brain (target head)</li><li>The skin must be open</li><li>The organs must be cut</li><li>The bone must be sawed</li><li>The patient must be lying down</li></ul>|soft_requirements=|optional_requirements=|blocker_requirements=<ul><li>The operation site must not be obstructed by clothing</li><li>The organ must not be cybernetic</li></ul>|tools={{Autowiki/SurgeryToolTemplate|tool_multiplier=1.15|tool_name=Hemostat|tool_icon=surgery_tool_hemostat}}{{Autowiki/SurgeryToolTemplate|tool_multiplier=2|tool_name=Cutters|tool_icon=surgery_tool_cutters}}{{Autowiki/SurgeryToolTemplate|tool_multiplier=2.85|tool_name=Package wrapper|tool_icon=surgery_tool_package_wrapper}}{{Autowiki/SurgeryToolTemplate|tool_multiplier=6.67|tool_name=Cable coil|tool_icon=surgery_tool_cable_coil}}|icon=surgery_organbrainwash|cstyle=background-color: #53277E; color: #FFFFFF;}}{{Autowiki/SurgeryTemplate|name=Encephalofractoplasty (Cortex Folding)|description=A biological upgrade which folds a patient's cerebral cortex into a fractal pattern, increasing neural density and flexibility.|hard_requirements=<ul><li>Operate on head (target head)</li><li>The skin must be open</li><li>The organs must be cut</li><li>The bone must be sawed</li><li>The patient must be lying down</li></ul>|soft_requirements=|optional_requirements=|blocker_requirements=<ul><li>The operation site must not be obstructed by clothing</li><li>The limb must not be cybernetic</li><li>The patient must not have undergone Encephalofractoplasty (Cortex Folding) OR Encephalopremoplasty (Cortex Imprinting) prior</li></ul>|tools={{Autowiki/SurgeryToolTemplate|tool_multiplier=1|tool_name=Hands|tool_icon=surgery_tool_hands}}|icon=surgery_limbbiowarecortex_folding|cstyle=background-color: #53277E; color: #FFFFFF;}}{{Autowiki/SurgeryTemplate|name=Wetware OS Labyrinthian Programming (Cortex Folding)|description=Reprogram a robotic patient's neural network in a downright eldritch programming language, giving space to non-standard neural patterns.|hard_requirements=<ul><li>Operate on head (target head)</li><li>The skin must be open</li><li>The organs must be cut</li><li>The bone must be sawed</li><li>The patient must be lying down</li></ul>|soft_requirements=|optional_requirements=|blocker_requirements=<ul><li>The operation site must not be obstructed by clothing</li><li>The limb must not be organic</li><li>The patient must not have undergone Wetware OS Labyrinthian Programming (Cortex Folding) OR Wetware OS Ver 2.0 (Cortex Imprinting) prior</li></ul>|tools={{Autowiki/SurgeryToolTemplate|tool_multiplier=1|tool_name=Hands|tool_icon=surgery_tool_hands}}|icon=surgery_limbbiowarecortex_foldingmechanic|cstyle=background: linear-gradient(115deg, #53277E 50%, #44964A 50%); color: #FFFFFF;}}{{Autowiki/SurgeryTemplate|name=Encephalopremoplasty (Cortex Imprinting)|description=A biological upgrade which carves a patient's cerebral cortex into a self-imprinting pattern, increasing neural density and resilience.|hard_requirements=<ul><li>Operate on head (target head)</li><li>The skin must be open</li><li>The organs must be cut</li><li>The bone must be sawed</li><li>The patient must be lying down</li></ul>|soft_requirements=|optional_requirements=|blocker_requirements=<ul><li>The operation site must not be obstructed by clothing</li><li>The limb must not be cybernetic</li><li>The patient must not have undergone Encephalofractoplasty (Cortex Folding) OR Encephalopremoplasty (Cortex Imprinting) prior</li></ul>|tools={{Autowiki/SurgeryToolTemplate|tool_multiplier=1|tool_name=Hands|tool_icon=surgery_tool_hands}}|icon=surgery_limbbiowarecortex_imprint|cstyle=background-color: #53277E; color: #FFFFFF;}}{{Autowiki/SurgeryTemplate|name=Wetware OS Ver 2.0 (Cortex Imprinting)|description=Update a robotic patient's operating system to a "newer version", improving overall performance and resilience. Shame about all the adware.|hard_requirements=<ul><li>Operate on head (target head)</li><li>The skin must be open</li><li>The organs must be cut</li><li>The bone must be sawed</li><li>The patient must be lying down</li></ul>|soft_requirements=|optional_requirements=|blocker_requirements=<ul><li>The operation site must not be obstructed by clothing</li><li>The limb must not be organic</li><li>The patient must not have undergone Wetware OS Labyrinthian Programming (Cortex Folding) OR Wetware OS Ver 2.0 (Cortex Imprinting) prior</li></ul>|tools={{Autowiki/SurgeryToolTemplate|tool_multiplier=1|tool_name=Hands|tool_icon=surgery_tool_hands}}|icon=surgery_limbbiowarecortex_imprintmechanic|cstyle=background: linear-gradient(115deg, #53277E 50%, #44964A 50%); color: #FFFFFF;}}{{Autowiki/SurgeryTemplate|name=Aggression Suppression Programming (Pacification)|description=Install malware which permanently inhibits the aggression programming of the patient's neural network, making the patient unwilling to cause direct harm.|hard_requirements=<ul><li>Operate on brain (target head)</li><li>The skin must be open</li><li>The bone must be sawed</li><li>The patient must be lying down</li></ul>|soft_requirements=|optional_requirements=|blocker_requirements=<ul><li>The blood vessels must not be unclamped</li><li>The operation site must not be obstructed by clothing</li><li>The organ must not be organic</li></ul>|tools={{Autowiki/SurgeryToolTemplate|tool_multiplier=1|tool_name=Multitool|tool_icon=surgery_tool_multitool}}{{Autowiki/SurgeryToolTemplate|tool_multiplier=2.85|tool_name=Hemostat|tool_icon=surgery_tool_hemostat}}{{Autowiki/SurgeryToolTemplate|tool_multiplier=2.85|tool_name=Screwdriver|tool_icon=surgery_tool_screwdriver}}{{Autowiki/SurgeryToolTemplate|tool_multiplier=6.67|tool_name=Pen|tool_icon=surgery_tool_pen}}|icon=surgery_organpacifymechanic|cstyle=background: linear-gradient(115deg, #53277E 50%, #44964A 50%); color: #FFFFFF;}}{{Autowiki/SurgeryTemplate|name=Wetware OS Destructive Defragmentation (Lobotomy)|description=An invasive surgical procedure which guarantees removal of almost all brain traumas, but might cause another permanent trauma in return.|hard_requirements=<ul><li>Operate on brain (target head)</li><li>The skin must be open</li><li>The bone must be sawed</li><li>The patient must be lying down</li></ul>|soft_requirements=|optional_requirements=|blocker_requirements=<ul><li>The blood vessels must not be unclamped</li><li>The operation site must not be obstructed by clothing</li><li>The organ must not be organic</li></ul>|tools={{Autowiki/SurgeryToolTemplate|tool_multiplier=1.15|tool_name=Multitool|tool_icon=surgery_tool_multitool}}{{Autowiki/SurgeryToolTemplate|tool_multiplier=1.85|tool_name=Energy sword|tool_icon=surgery_tool_energy_sword}}{{Autowiki/SurgeryToolTemplate|tool_multiplier=2.85|tool_name=Knife|tool_icon=surgery_tool_knife}}{{Autowiki/SurgeryToolTemplate|tool_multiplier=4|tool_name=Shard|tool_icon=surgery_tool_shard}}{{Autowiki/SurgeryToolTemplate|tool_multiplier=5|tool_name=Any sharp edged item|tool_icon=surgery_tool_any_sharp_edged_item}}|icon=surgery_organlobotomymechanic|cstyle=background: linear-gradient(115deg, #53277E 50%, #44964A 50%); color: #FFFFFF;}}{{Autowiki/SurgeryTemplate|name=Experimental Androtomy (Experimental Dissection and Autopsy)|description=An experimental surgical procedure that dissects bodies in exchange for research points at ancient R&D consoles.|hard_requirements=<ul><li>Operate on chest (target chest)</li><li>The patient must be lying down</li><li>The patient must be deceased</li><li>The patient must not have been dissected prior</li><li>The skin must be cut or opened</li></ul>|soft_requirements=|optional_requirements=|blocker_requirements=|tools={{Autowiki/SurgeryToolTemplate|tool_multiplier=1|tool_name=Autopsy scanner|tool_icon=surgery_tool_autopsy_scanner}}{{Autowiki/SurgeryToolTemplate|tool_multiplier=1.66|tool_name=Scalpel|tool_icon=surgery_tool_scalpel}}{{Autowiki/SurgeryToolTemplate|tool_multiplier=5|tool_name=Knife|tool_icon=surgery_tool_knife}}{{Autowiki/SurgeryToolTemplate|tool_multiplier=10|tool_name=Shard|tool_icon=surgery_tool_shard}}|icon=surgery_basicdissection|cstyle=background-color: #53277E; color: #FFFFFF;}}{{Autowiki/SurgeryTemplate|name=Xanthoneuroplasty (Grounded Nerves)|description=Reroute a patient's nerves to act as grounding rods, protecting them from electrical shocks.|hard_requirements=<ul><li>Operate on chest (target chest)</li><li>The skin must be open</li><li>The organs must be cut</li><li>The bone must be sawed</li><li>The patient must be lying down</li></ul>|soft_requirements=|optional_requirements=|blocker_requirements=<ul><li>The operation site must not be obstructed by clothing</li><li>The limb must not be cybernetic</li><li>The patient must not have undergone Symneurodesis (Spliced Nerves) OR Xanthoneuroplasty (Grounded Nerves) prior</li></ul>|tools={{Autowiki/SurgeryToolTemplate|tool_multiplier=1|tool_name=Hands|tool_icon=surgery_tool_hands}}|icon=surgery_limbbiowarenerve_grounding|cstyle=background-color: #53277E; color: #FFFFFF;}}{{Autowiki/SurgeryTemplate|name=System Shock Dampening (Grounded Nerves)|description=Install grounding rods into a robotic patient's nervous system, protecting it from electrical shocks.|hard_requirements=<ul><li>Operate on chest (target chest)</li><li>The skin must be open</li><li>The organs must be cut</li><li>The bone must be sawed</li><li>The patient must be lying down</li></ul>|soft_requirements=|optional_requirements=|blocker_requirements=<ul><li>The operation site must not be obstructed by clothing</li><li>The limb must not be organic</li><li>The patient must not have undergone System Automatic Reset Subroutine (Spliced Nerves) OR System Shock Dampening (Grounded Nerves) prior</li></ul>|tools={{Autowiki/SurgeryToolTemplate|tool_multiplier=1|tool_name=Hands|tool_icon=surgery_tool_hands}}|icon=surgery_limbbiowarenerve_groundingmechanic|cstyle=background: linear-gradient(115deg, #53277E 50%, #44964A 50%); color: #FFFFFF;}}{{Autowiki/SurgeryTemplate|name=Bionecroplasty (Necrotic Revival)|description=An experimental procedure which induces the growth of a Romerol tumor inside the patient's brain.|hard_requirements=<ul><li>The skin must be open</li><li>The bone must be sawed</li><li>The patient must be lying down</li><li>The limb must have a brain present</li></ul>|soft_requirements=<ul><li>The patient or tool must contain >1u Rezadone</li><li>The patient or tool must contain >1u Zombie Powder</li></ul>|optional_requirements=|blocker_requirements=<ul><li>The blood vessels must not be unclamped</li><li>The operation site must not be obstructed by clothing</li><li>The limb must not already have a Romerol tumor</li></ul>|tools={{Autowiki/SurgeryToolTemplate|tool_multiplier=1|tool_name=Syringe|tool_icon=surgery_tool_syringe}}{{Autowiki/SurgeryToolTemplate|tool_multiplier=3.33|tool_name=Pen|tool_icon=surgery_tool_pen}}|icon=surgery_limbbionecrosis|cstyle=background-color: #53277E; color: #FFFFFF;}}{{Autowiki/SurgeryTemplate|name=Sleeper Agent Implantation (Brainwash)|description=A surgical procedure which directly implants a directive into the patient's brain, making it their absolute priority. It can be cleared using a mindshield implant.|hard_requirements=<ul><li>Operate on brain (target head)</li><li>The skin must be open</li><li>The organs must be cut</li><li>The bone must be sawed</li><li>The patient must be lying down</li></ul>|soft_requirements=|optional_requirements=|blocker_requirements=<ul><li>The operation site must not be obstructed by clothing</li><li>The organ must not be cybernetic</li></ul>|tools={{Autowiki/SurgeryToolTemplate|tool_multiplier=1.15|tool_name=Hemostat|tool_icon=surgery_tool_hemostat}}{{Autowiki/SurgeryToolTemplate|tool_multiplier=2|tool_name=Cutters|tool_icon=surgery_tool_cutters}}{{Autowiki/SurgeryToolTemplate|tool_multiplier=2.85|tool_name=Package wrapper|tool_icon=surgery_tool_package_wrapper}}{{Autowiki/SurgeryToolTemplate|tool_multiplier=6.67|tool_name=Cable coil|tool_icon=surgery_tool_cable_coil}}|icon=surgery_organbrainwashsleeper|cstyle=background-color: #53277E; color: #FFFFFF;}}{{Autowiki/SurgeryTemplate|name=Sleeper Agent Programming (Brainwash)|description=A surgical procedure which directly implants a directive into the patient's brain, making it their absolute priority. It can be cleared using a mindshield implant.|hard_requirements=<ul><li>Operate on brain (target head)</li><li>The skin must be open</li><li>The organs must be cut</li><li>The bone must be sawed</li><li>The patient must be lying down</li></ul>|soft_requirements=|optional_requirements=|blocker_requirements=<ul><li>The operation site must not be obstructed by clothing</li><li>The organ must not be organic</li></ul>|tools={{Autowiki/SurgeryToolTemplate|tool_multiplier=1.15|tool_name=Multitool|tool_icon=surgery_tool_multitool}}{{Autowiki/SurgeryToolTemplate|tool_multiplier=2|tool_name=Hemostat|tool_icon=surgery_tool_hemostat}}{{Autowiki/SurgeryToolTemplate|tool_multiplier=2|tool_name=Cutters|tool_icon=surgery_tool_cutters}}{{Autowiki/SurgeryToolTemplate|tool_multiplier=2.85|tool_name=Package wrapper|tool_icon=surgery_tool_package_wrapper}}{{Autowiki/SurgeryToolTemplate|tool_multiplier=6.67|tool_name=Cable coil|tool_icon=surgery_tool_cable_coil}}|icon=surgery_organbrainwashsleepermechanic|cstyle=background: linear-gradient(115deg, #53277E 50%, #44964A 50%); color: #FFFFFF;}}{{Autowiki/SurgeryTemplate|name=Lobotomy (Lobotomy)|description=An invasive surgical procedure which guarantees removal of almost all brain traumas, but might cause another permanent trauma in return.|hard_requirements=<ul><li>Operate on brain (target head)</li><li>The skin must be open</li><li>The bone must be sawed</li><li>The patient must be lying down</li></ul>|soft_requirements=|optional_requirements=|blocker_requirements=<ul><li>The blood vessels must not be unclamped</li><li>The operation site must not be obstructed by clothing</li><li>The organ must not be cybernetic</li></ul>|tools={{Autowiki/SurgeryToolTemplate|tool_multiplier=1.15|tool_name=Scalpel|tool_icon=surgery_tool_scalpel}}{{Autowiki/SurgeryToolTemplate|tool_multiplier=0.55|tool_name=Energy sword|tool_icon=surgery_tool_energy_sword}}{{Autowiki/SurgeryToolTemplate|tool_multiplier=2.85|tool_name=Knife|tool_icon=surgery_tool_knife}}{{Autowiki/SurgeryToolTemplate|tool_multiplier=4|tool_name=Shard|tool_icon=surgery_tool_shard}}{{Autowiki/SurgeryToolTemplate|tool_multiplier=5|tool_name=Any sharp edged item|tool_icon=surgery_tool_any_sharp_edged_item}}|icon=surgery_organlobotomy|cstyle=background-color: #53277E; color: #FFFFFF;}}{{Autowiki/SurgeryTemplate|name=Myovasculoplasty (Muscled Veins)|description=Add a muscled membrane to a patient's veins, allowing them to pump blood without a heart.|hard_requirements=<ul><li>Operate on chest (target chest)</li><li>The skin must be open</li><li>The organs must be cut</li><li>The bone must be sawed</li><li>The patient must be lying down</li></ul>|soft_requirements=|optional_requirements=|blocker_requirements=<ul><li>The operation site must not be obstructed by clothing</li><li>The limb must not be cybernetic</li><li>The patient must not have undergone Symvasculodesis (Vein Threading) OR Myovasculoplasty (Muscled Veins) prior</li></ul>|tools={{Autowiki/SurgeryToolTemplate|tool_multiplier=1|tool_name=Hands|tool_icon=surgery_tool_hands}}|icon=surgery_limbbiowaremuscled_veins|cstyle=background-color: #53277E; color: #FFFFFF;}}{{Autowiki/SurgeryTemplate|name=Hydraulics Redundancy Subroutine (Muscled Veins)|description=Add redundancies to a robotic patient's hydraulic system, allowing it to pump fluids without an engine or pump.|hard_requirements=<ul><li>Operate on chest (target chest)</li><li>The skin must be open</li><li>The organs must be cut</li><li>The bone must be sawed</li><li>The patient must be lying down</li></ul>|soft_requirements=|optional_requirements=|blocker_requirements=<ul><li>The operation site must not be obstructed by clothing</li><li>The limb must not be organic</li><li>The patient must not have undergone Hydraulics Routing Optimization (Threaded Veins) OR Hydraulics Redundancy Subroutine (Muscled Veins) prior</li></ul>|tools={{Autowiki/SurgeryToolTemplate|tool_multiplier=1|tool_name=Hands|tool_icon=surgery_tool_hands}}|icon=surgery_limbbiowaremuscled_veinsmechanic|cstyle=background: linear-gradient(115deg, #53277E 50%, #44964A 50%); color: #FFFFFF;}}{{Autowiki/SurgeryTemplate|name=Paxopsy (Pacification)|description=A surgical procedure which permanently inhibits the aggression center of the brain, making the patient unwilling to cause direct harm.|hard_requirements=<ul><li>Operate on brain (target head)</li><li>The skin must be open</li><li>The bone must be sawed</li><li>The patient must be lying down</li></ul>|soft_requirements=|optional_requirements=|blocker_requirements=<ul><li>The blood vessels must not be unclamped</li><li>The operation site must not be obstructed by clothing</li><li>The organ must not be cybernetic</li></ul>|tools={{Autowiki/SurgeryToolTemplate|tool_multiplier=1|tool_name=Hemostat|tool_icon=surgery_tool_hemostat}}{{Autowiki/SurgeryToolTemplate|tool_multiplier=2.85|tool_name=Screwdriver|tool_icon=surgery_tool_screwdriver}}{{Autowiki/SurgeryToolTemplate|tool_multiplier=6.67|tool_name=Pen|tool_icon=surgery_tool_pen}}|icon=surgery_organpacify|cstyle=background-color: #53277E; color: #FFFFFF;}}{{Autowiki/SurgeryTemplate|name=Pteroplasty (Wing Repair)|description=A surgical procedure that repairs damaged wings using Synthflesh.|hard_requirements=<ul><li>Operate on moth wings (target chest)</li><li>The skin must be open</li><li>The patient must be lying down</li><li>The wings must be burnt</li><li>The patient must be dosed with >=5u Synthflesh</li></ul>|soft_requirements=|optional_requirements=|blocker_requirements=<ul><li>The blood vessels must not be unclamped</li><li>The operation site must not be obstructed by clothing</li><li>If the limb has bones, they must be intact</li></ul>|tools={{Autowiki/SurgeryToolTemplate|tool_multiplier=1.15|tool_name=Hemostat|tool_icon=surgery_tool_hemostat}}{{Autowiki/SurgeryToolTemplate|tool_multiplier=2.85|tool_name=Screwdriver|tool_icon=surgery_tool_screwdriver}}{{Autowiki/SurgeryToolTemplate|tool_multiplier=6.67|tool_name=Pen|tool_icon=surgery_tool_pen}}|icon=surgery_organfix_wings|cstyle=background-color: #53277E; color: #FFFFFF;}}{{Autowiki/SurgeryTemplate|name=Neural Reprogramming (Brainwash)|description=Install malware which directly implants a directive into the robotic patient's operating system, making it their absolute priority. It can be cleared using a mindshield implant.|hard_requirements=<ul><li>Operate on brain (target head)</li><li>The skin must be open</li><li>The organs must be cut</li><li>The bone must be sawed</li><li>The patient must be lying down</li></ul>|soft_requirements=|optional_requirements=|blocker_requirements=<ul><li>The operation site must not be obstructed by clothing</li><li>The organ must not be organic</li></ul>|tools={{Autowiki/SurgeryToolTemplate|tool_multiplier=1.15|tool_name=Multitool|tool_icon=surgery_tool_multitool}}{{Autowiki/SurgeryToolTemplate|tool_multiplier=2|tool_name=Hemostat|tool_icon=surgery_tool_hemostat}}{{Autowiki/SurgeryToolTemplate|tool_multiplier=2|tool_name=Cutters|tool_icon=surgery_tool_cutters}}{{Autowiki/SurgeryToolTemplate|tool_multiplier=2.85|tool_name=Package wrapper|tool_icon=surgery_tool_package_wrapper}}{{Autowiki/SurgeryToolTemplate|tool_multiplier=6.67|tool_name=Cable coil|tool_icon=surgery_tool_cable_coil}}|icon=surgery_organbrainwashmechanic|cstyle=background: linear-gradient(115deg, #53277E 50%, #44964A 50%); color: #FFFFFF;}}{{Autowiki/SurgeryTemplate|name=Arthroplasty (Ligament Hooks)|description=Reshape a patient's ligaments to allow limbs to be manually reattached if severed - at the cost of making them easier to detach.|hard_requirements=<ul><li>Operate on chest (target chest)</li><li>The skin must be open</li><li>The organs must be cut</li><li>The bone must be sawed</li><li>The patient must be lying down</li></ul>|soft_requirements=|optional_requirements=|blocker_requirements=<ul><li>The operation site must not be obstructed by clothing</li><li>The limb must not be cybernetic</li><li>The patient must not have undergone Arthroplasty (Ligament Hooks) OR Arthrorrhaphy (Ligament Reinforcement) prior</li></ul>|tools={{Autowiki/SurgeryToolTemplate|tool_multiplier=1|tool_name=Hands|tool_icon=surgery_tool_hands}}|icon=surgery_limbbiowareligament_hook|cstyle=background-color: #53277E; color: #FFFFFF;}}{{Autowiki/SurgeryTemplate|name=Anchor Point Snaplocks (Ligament Hooks)|description=Refactor a robotic patient's limb joints to allow for rapid deatchment, allowing limbs to be manually reattached if severed - at the cost of making them easier to detach as well.|hard_requirements=<ul><li>Operate on chest (target chest)</li><li>The skin must be open</li><li>The organs must be cut</li><li>The bone must be sawed</li><li>The patient must be lying down</li></ul>|soft_requirements=|optional_requirements=|blocker_requirements=<ul><li>The operation site must not be obstructed by clothing</li><li>The limb must not be organic</li><li>The patient must not have undergone Anchor Point Snaplocks (Ligament Hooks) OR Anchor Point Reinforcement (Ligament Reinforcement) prior</li></ul>|tools={{Autowiki/SurgeryToolTemplate|tool_multiplier=1|tool_name=Hands|tool_icon=surgery_tool_hands}}|icon=surgery_limbbiowareligament_hookmechanic|cstyle=background: linear-gradient(115deg, #53277E 50%, #44964A 50%); color: #FFFFFF;}}{{Autowiki/SurgeryTemplate|name=Symneurodesis (Spliced Nerves)|description=Splice a patient's nerves together to make them more resistant to stuns.|hard_requirements=<ul><li>Operate on chest (target chest)</li><li>The skin must be open</li><li>The organs must be cut</li><li>The bone must be sawed</li><li>The patient must be lying down</li></ul>|soft_requirements=|optional_requirements=|blocker_requirements=<ul><li>The operation site must not be obstructed by clothing</li><li>The limb must not be cybernetic</li><li>The patient must not have undergone Symneurodesis (Spliced Nerves) OR Xanthoneuroplasty (Grounded Nerves) prior</li></ul>|tools={{Autowiki/SurgeryToolTemplate|tool_multiplier=1|tool_name=Hands|tool_icon=surgery_tool_hands}}|icon=surgery_limbbiowarenerve_splicing|cstyle=background-color: #53277E; color: #FFFFFF;}}{{Autowiki/SurgeryTemplate|name=System Automatic Reset Subroutine (Spliced Nerves)|description=Upgrade a robotic patient's automatic systems, allowing it to better resist stuns.|hard_requirements=<ul><li>Operate on chest (target chest)</li><li>The skin must be open</li><li>The organs must be cut</li><li>The bone must be sawed</li><li>The patient must be lying down</li></ul>|soft_requirements=|optional_requirements=|blocker_requirements=<ul><li>The operation site must not be obstructed by clothing</li><li>The limb must not be organic</li><li>The patient must not have undergone System Automatic Reset Subroutine (Spliced Nerves) OR System Shock Dampening (Grounded Nerves) prior</li></ul>|tools={{Autowiki/SurgeryToolTemplate|tool_multiplier=1|tool_name=Hands|tool_icon=surgery_tool_hands}}|icon=surgery_limbbiowarenerve_splicingmechanic|cstyle=background: linear-gradient(115deg, #53277E 50%, #44964A 50%); color: #FFFFFF;}}{{Autowiki/SurgeryTemplate|name=Arthrorrhaphy (Ligament Reinforcement)|description=Strengthen a patient's ligaments to make dismemberment more difficult, at the cost of making nerve connections easier to interrupt.|hard_requirements=<ul><li>Operate on chest (target chest)</li><li>The skin must be open</li><li>The organs must be cut</li><li>The bone must be sawed</li><li>The patient must be lying down</li></ul>|soft_requirements=|optional_requirements=|blocker_requirements=<ul><li>The operation site must not be obstructed by clothing</li><li>The limb must not be cybernetic</li><li>The patient must not have undergone Arthroplasty (Ligament Hooks) OR Arthrorrhaphy (Ligament Reinforcement) prior</li></ul>|tools={{Autowiki/SurgeryToolTemplate|tool_multiplier=1|tool_name=Hands|tool_icon=surgery_tool_hands}}|icon=surgery_limbbiowareligament_reinforcement|cstyle=background-color: #53277E; color: #FFFFFF;}}{{Autowiki/SurgeryTemplate|name=Anchor Point Reinforcement (Ligament Reinforcement)|description=Reinforce a robotic patient's limb joints to prevent dismemberment, at the cost of making nerve connections easier to interrupt.|hard_requirements=<ul><li>Operate on chest (target chest)</li><li>The skin must be open</li><li>The organs must be cut</li><li>The bone must be sawed</li><li>The patient must be lying down</li></ul>|soft_requirements=|optional_requirements=|blocker_requirements=<ul><li>The operation site must not be obstructed by clothing</li><li>The limb must not be organic</li><li>The patient must not have undergone Anchor Point Snaplocks (Ligament Hooks) OR Anchor Point Reinforcement (Ligament Reinforcement) prior</li></ul>|tools={{Autowiki/SurgeryToolTemplate|tool_multiplier=1|tool_name=Hands|tool_icon=surgery_tool_hands}}|icon=surgery_limbbiowareligament_reinforcementmechanic|cstyle=background: linear-gradient(115deg, #53277E 50%, #44964A 50%); color: #FFFFFF;}}{{Autowiki/SurgeryTemplate|name=Tend Wounds+|description=Perform superficial wound care on a patient's bruises and burns.|hard_requirements=<ul><li>Operate on chest (target chest)</li><li>The patient must be lying down</li><li>The patient must have brute or burn damage</li><li>The skin must be cut or opened</li></ul>|soft_requirements=|optional_requirements=|blocker_requirements=<ul><li>The patient must not be robotic</li></ul>|tools={{Autowiki/SurgeryToolTemplate|tool_multiplier=1|tool_name=Hemostat|tool_icon=surgery_tool_hemostat}}{{Autowiki/SurgeryToolTemplate|tool_multiplier=1.5|tool_name=Screwdriver|tool_icon=surgery_tool_screwdriver}}{{Autowiki/SurgeryToolTemplate|tool_multiplier=1.67|tool_name=Cutters|tool_icon=surgery_tool_cutters}}{{Autowiki/SurgeryToolTemplate|tool_multiplier=1.8|tool_name=Pen|tool_icon=surgery_tool_pen}}|icon=surgery_basictend_woundsupgraded|cstyle=background-color: #53277E; color: #FFFFFF;}}{{Autowiki/SurgeryTemplate|name=Tend Wounds++|description=Perform superficial wound care on a patient's bruises and burns.|hard_requirements=<ul><li>Operate on chest (target chest)</li><li>The patient must be lying down</li><li>The patient must have brute or burn damage</li><li>The skin must be cut or opened</li></ul>|soft_requirements=|optional_requirements=|blocker_requirements=<ul><li>The patient must not be robotic</li></ul>|tools={{Autowiki/SurgeryToolTemplate|tool_multiplier=1|tool_name=Hemostat|tool_icon=surgery_tool_hemostat}}{{Autowiki/SurgeryToolTemplate|tool_multiplier=1.5|tool_name=Screwdriver|tool_icon=surgery_tool_screwdriver}}{{Autowiki/SurgeryToolTemplate|tool_multiplier=1.67|tool_name=Cutters|tool_icon=surgery_tool_cutters}}{{Autowiki/SurgeryToolTemplate|tool_multiplier=1.8|tool_name=Pen|tool_icon=surgery_tool_pen}}|icon=surgery_basictend_woundsupgradedmaster|cstyle=background-color: #53277E; color: #FFFFFF;}}{{Autowiki/SurgeryTemplate|name=Advanced Tend Wounds|description=Perform superficial wound care on a patient's bruises and burns.|hard_requirements=<ul><li>Operate on chest (target chest)</li><li>The patient must be lying down</li><li>The patient must have brute or burn damage</li><li>The skin must be cut or opened</li></ul>|soft_requirements=|optional_requirements=|blocker_requirements=<ul><li>The patient must not be robotic</li></ul>|tools={{Autowiki/SurgeryToolTemplate|tool_multiplier=1|tool_name=Hemostat|tool_icon=surgery_tool_hemostat}}{{Autowiki/SurgeryToolTemplate|tool_multiplier=1.5|tool_name=Screwdriver|tool_icon=surgery_tool_screwdriver}}{{Autowiki/SurgeryToolTemplate|tool_multiplier=1.67|tool_name=Cutters|tool_icon=surgery_tool_cutters}}{{Autowiki/SurgeryToolTemplate|tool_multiplier=1.8|tool_name=Pen|tool_icon=surgery_tool_pen}}|icon=surgery_basictend_woundscombo|cstyle=background-color: #53277E; color: #FFFFFF;}}{{Autowiki/SurgeryTemplate|name=Advanced Tend Wounds+|description=Perform superficial wound care on a patient's bruises and burns.|hard_requirements=<ul><li>Operate on chest (target chest)</li><li>The patient must be lying down</li><li>The patient must have brute or burn damage</li><li>The skin must be cut or opened</li></ul>|soft_requirements=|optional_requirements=|blocker_requirements=<ul><li>The patient must not be robotic</li></ul>|tools={{Autowiki/SurgeryToolTemplate|tool_multiplier=1|tool_name=Hemostat|tool_icon=surgery_tool_hemostat}}{{Autowiki/SurgeryToolTemplate|tool_multiplier=1.5|tool_name=Screwdriver|tool_icon=surgery_tool_screwdriver}}{{Autowiki/SurgeryToolTemplate|tool_multiplier=1.67|tool_name=Cutters|tool_icon=surgery_tool_cutters}}{{Autowiki/SurgeryToolTemplate|tool_multiplier=1.8|tool_name=Pen|tool_icon=surgery_tool_pen}}|icon=surgery_basictend_woundscomboupgraded|cstyle=background-color: #53277E; color: #FFFFFF;}}{{Autowiki/SurgeryTemplate|name=Advanced Tend Wounds++|description=Perform superficial wound care on a patient's bruises and burns.|hard_requirements=<ul><li>Operate on chest (target chest)</li><li>The patient must be lying down</li><li>The patient must have brute or burn damage</li><li>The skin must be cut or opened</li></ul>|soft_requirements=|optional_requirements=|blocker_requirements=<ul><li>The patient must not be robotic</li></ul>|tools={{Autowiki/SurgeryToolTemplate|tool_multiplier=1|tool_name=Hemostat|tool_icon=surgery_tool_hemostat}}{{Autowiki/SurgeryToolTemplate|tool_multiplier=1.5|tool_name=Screwdriver|tool_icon=surgery_tool_screwdriver}}{{Autowiki/SurgeryToolTemplate|tool_multiplier=1.67|tool_name=Cutters|tool_icon=surgery_tool_cutters}}{{Autowiki/SurgeryToolTemplate|tool_multiplier=1.8|tool_name=Pen|tool_icon=surgery_tool_pen}}|icon=surgery_basictend_woundscomboupgradedmaster|cstyle=background-color: #53277E; color: #FFFFFF;}}{{Autowiki/SurgeryTemplate|name=Symvasculodesis (Vein Threading)|description=Weave a patient's veins into a reinforced mesh, reducing blood loss from injuries.|hard_requirements=<ul><li>Operate on chest (target chest)</li><li>The skin must be open</li><li>The organs must be cut</li><li>The bone must be sawed</li><li>The patient must be lying down</li></ul>|soft_requirements=|optional_requirements=|blocker_requirements=<ul><li>The operation site must not be obstructed by clothing</li><li>The limb must not be cybernetic</li><li>The patient must not have undergone Symvasculodesis (Vein Threading) OR Myovasculoplasty (Muscled Veins) prior</li></ul>|tools={{Autowiki/SurgeryToolTemplate|tool_multiplier=1|tool_name=Hands|tool_icon=surgery_tool_hands}}|icon=surgery_limbbiowarevein_threading|cstyle=background-color: #53277E; color: #FFFFFF;}}{{Autowiki/SurgeryTemplate|name=Hydraulics Routing Optimization (Threaded Veins)|description=Optimize the routing of a robotic patient's hydraulic system, reducing fluid loss from leaks.|hard_requirements=<ul><li>Operate on chest (target chest)</li><li>The skin must be open</li><li>The organs must be cut</li><li>The bone must be sawed</li><li>The patient must be lying down</li></ul>|soft_requirements=|optional_requirements=|blocker_requirements=<ul><li>The operation site must not be obstructed by clothing</li><li>The limb must not be organic</li><li>The patient must not have undergone Hydraulics Routing Optimization (Threaded Veins) OR Hydraulics Redundancy Subroutine (Muscled Veins) prior</li></ul>|tools={{Autowiki/SurgeryToolTemplate|tool_multiplier=1|tool_name=Hands|tool_icon=surgery_tool_hands}}|icon=surgery_limbbiowarevein_threadingmechanic|cstyle=background: linear-gradient(115deg, #53277E 50%, #44964A 50%); color: #FFFFFF;}}{{Autowiki/SurgeryTemplate|name=Viroplasty (Viral Bonding)|description=A surgical procedure that forces a symbiotic relationship between a virus and its host. The patient will be completely immune to the effects of the virus, but will carry and spread it to others.|hard_requirements=<ul><li>Operate on chest (target chest)</li><li>The skin must be open</li><li>The organs must be cut</li><li>The patient must be lying down</li><li>The patient must have a virus to bond</li><li>The patient must be dosed with >=1u Spaceacillin</li><li>The patient must be dosed with >=1u Virus Food</li><li>The patient must be dosed with >=1u Formaldehyde</li></ul>|soft_requirements=|optional_requirements=|blocker_requirements=<ul><li>The operation site must not be obstructed by clothing</li><li>The patient must not be robotic</li></ul>|tools={{Autowiki/SurgeryToolTemplate|tool_multiplier=1|tool_name=Cautery|tool_icon=surgery_tool_cautery}}{{Autowiki/SurgeryToolTemplate|tool_multiplier=2|tool_name=Welder|tool_icon=surgery_tool_welder}}{{Autowiki/SurgeryToolTemplate|tool_multiplier=3.33|tool_name=Any heat source|tool_icon=surgery_tool_any_heat_source}}|icon=surgery_basicviral_bonding|cstyle=background-color: #53277E; color: #FFFFFF;}}}}
'''Purple''' operations are locked - typically behind technology from science, but sometimes behind rare or traitorous surgical disks. They cannot be undergone without first being loaded into an operating computer.
{{Template:Autowiki/Content/Surgeries}}
Latest revision as of 01:26, 15 July 2026
All surgery requires a set of medical tools, typically found in the Operating Theatre, along with an operating table.
While every operation has an intended tool, you are not limited to it alone. Every operation has a list of alternative tools you can use instead. Beside each tool is a multiplier which indicates how much of a penalty to speed you are given for using the supplied tool.
These multipliers stack multiplicatively with those from operating site or chemicals (see Beginning of any Operation).
Note, speed penalty is capped to 2x the base time the step would have taken. A step that takes 10 seconds would cap at 20 seconds, for example.
However, every second after that cap will instead add 1 percentage point into the odds of a failure. Failing may cause extra damage or other effects.
So for example:
Say a surgery step takes 10 seconds by default, but you use a pen (2.5x) instead of a hemostat and do it on the floor (2x) instead of a surgery table.
Now the surgery is slowed to 50 seconds, but it's capped to 20 seconds.
Those 30 extra seconds that were removed is now your chance to fail the operation.
Result: The step takes 20 seconds and has a 30% chance to fail.
The Operation Process
Step 1: Undress the part of the patient that needs surgery. You can do this by dragging them onto yourself, and then clicking the clothes you want to remove from them in the pop-up. Alternatively, some clothes like jumpsuits can be adjusted out of the way, to save yourself some time.
Important: The uniform the patient is wearing usually covers both legs, arms, groin and torso. Helmets, eyewear and masks always obscure the eyes, make sure to remove them if working on the eyes.
Step 2: Place the patient onto the operating table. Do this doing a Hold CTRL and left-click a person with your hand empty. It doesn't matter if Combat ModeToggle with 4 or F by default. Left-clicking people with an empty hand will Harm them if on, or Help them if off. Prevents you from switching places or being pushed when colliding with people. is on or off. Repeat after a short delay to upgrade grab to aggressive (lvl 2), neck (lvl 3) and strangling (lvl 4).on the patient. Then left click the operating table to place the patient on it. You can also Ordinary right-click. It doesn't matter if Combat ModeToggle with 4 or F by default. Left-clicking people with an empty hand will Harm them if on, or Help them if off. Prevents you from switching places or being pushed when colliding with people. is on or not. shove a person onto the table and tell them to rest, though they might not appreciate this.
If there is no operating table, you can use: Stasis bed (1.15x), any table (1.25x), any bed (1.5x), ask them to lie on the floor (2x). The speed of completing every step will be reduced.
Step 2.1 (Optional) Splash on, spray or apply a patch with a reagent like Miner's Salve (0.9x), Sterilizine 0.8x), alcoholic drinks (up to ~0.5x*), or Honey (0.6x) for faster surgery speed.
The stronger the alcohol, the more effective! The formula is: (booze power / 650). For example: Ethanol gives ~0.9x surgery speed, Manly Dorf ~0.85x, Bacchus' Blessing ~0.5x.
Step 2.2: (Optional) Use a tank of anesthetic and a breath mask to make your patient sleep. This way patient won't experience agonizing pain, decreasing their mood.
Step 3: (Optional if the patient is buckled to an operating table ) Place drapes or bedsheet over the part of body you are operating.
If you performed step 1 wrong, it will tell you that you must remove clothing first. If you continue without fixing it, you will stab your patient instead of doing surgery.
Step 4: Turn off Combat ModeToggle with 4 or F by default. Left-clicking people with an empty hand will Harm them if on, or Help them if off. Prevents you from switching places or being pushed when colliding with people. . Pro tip: Ordinary right-click. It doesn't matter if Combat ModeToggle with 4 or F by default. Left-clicking people with an empty hand will Harm them if on, or Help them if off. Prevents you from switching places or being pushed when colliding with people. is on or not. will make you fail every surgery step on purpose.
Step 5: Aim at the appropriate body part (important!).
Step 6:Turn offCombat ModeToggle with 4 or F by default. Left-clicking people with an empty hand will Harm them if on, or Help them if off. Prevents you from switching places or being pushed when colliding with people. and then left-click.Begin surgery (see the steps below!).
To get to the operation you want to complete, it will require you get the patient to the necessary state*. For example, an overwhelming majority of surgeries will require the patient's skin be opened first. To open the skin you'll need to complete "Retract skin" first, and to be able to complete "Retract skin", you will need to "Make skin incision". More complicated surgeries require more complicated states, such as sawing bones.
While a patient's undergoing surgery, they will slowly lose blood. Try not to dawdle!
Note: Some patients you receive will be in a state already ready for surgery! Species like Plasmamen have no skin, and folk with grievous chest wounds clearly have their skin open already, so you have nothing to make an incision in. You can simply skip that step!
Step 7: Complete your surgery
After getting to the state required, you can do whatever operation you intended. Congratulations, you just did surgery! That wasn't so bad, right?
Step 7.5: Repeat!
Feel free to do any other operation while the patient is cut open. States don't automatically get cleared after you're done! You can save yourself a lot of time this way.
Step 8: Close the patient
After all is said and done, don't forget to cauterize or suture the operated bodypart! The patient will continue to bleed if you don't.
And you're done! Send the patient out with a lollipop and a smile.
Dr. Ners says: "When performing surgery on species that have no skin such as golems or plasmamen, a widened chest cavity can be closed using a retractor! And remember to use your operating computer if you get lost."
Weird Organs and You
Many species contain unique organs that might not be easily identifiable in function. And as such we've compiled a list of them to familiarize yourself with should you have the unfortunate responsibility of having to take them out or stick them into your fellow crewmember. Or fortunate- if you're into that sort of thing. This is not a complete list, and is meant to help you with some niche edge cases you might come across while doing surgery.
Ethereals
Electric Discharger - Tongue
Crystal Core - Heart
Aeration Reticulum - Lungs
Biological Battery - Stomach
Ethereals contain a normal Liver, Appendix, Eyes, and Ears.
Flypersons
A truly harrowing case should they ever happen to come across your operating table, Flypersons not only have superfluous organs, but their organ names and icons are randomly generated from a pool. When in doubt, put everything you can back inside and call it a day.
Golems
Crystalline Matrix - Brain
Resonating Crystal - Eyes
Porous Rock - Replaces the Liver, gives nutrients from minerals
Silicate Grinder - Stomach, rejects normal consumables- only allowing the golem to eat minerals
Internal Forge - Replaces the appendix, allows the golem to smelt minerals
Golems do not have a heart or lungs, nor equivalent organs for such.
Hemophages
Atrophied Lungs - Lungs, not actually required for hemophages to survive since they don't breathe normally.
Pulsating Tumor - Heart, gives the hemophage their abilities and corrupts normal organs into hemophage variants.
Corrupted Stomach - Stomach, Doesn't allow the hemophage to consume most things except for blood, normally.
Other corrupted organs function the same as their normal counterparts.
Plasmamen
Plasma Filter - Lungs
Reagent Processing Crystal - Liver
Digestive Crystal - Stomach
Plasmamen do not have a heart or appendix, nor equivalent organs for such.
Podpersons
Pod Nucleus - Brain
Pod Mitochondria - Heart
Pod Vacuole - Lungs
Pod Peroxisome - Liver
Pod Chloroplast - Stomach
Pod Endoplasmic Reticulum / Golgi Apparatus / Plastid / Vesicle - Appendix, name generated from a pool
Slimepersons
Core - Brain
Core Audiosomes - Ears
Photosensitive Eyespots - Eyes
Slime Vacuole - Lungs
Endoplasmic Reticulum - Liver
Golgi Apparatus - Stomach
Slimes do not contain an appendix, nor an equivalent organ for such.
Operations
What follows is a full list of every operation that you can undergo.
Green operations are mechanical surgeries and will only work on cybernetic patients.
Purple operations are locked - typically behind technology from science, but sometimes behind rare or traitorous surgical disks. They cannot be undergone without first being loaded into an operating computer.
Engine Diagnostic (Heart Surgery)
Graft a bypass onto a patient's damaged heart to restore proper blood flow. This procedure can only be performed once per organ.
All of these are required:
Operate on heart (target chest)
The skin must be open
The organs must be cut
The bone must be sawed
The patient must be lying down
The organ must be moderately damaged
However:
The operation site must not be obstructed by clothing
The organ must not be organic
The organ must not have been surgically repaired prior
Tool
Speed Multiplier
Crowbar
1.05x
Scalpel
1.05x
Energy sword
1.5x
Knife
2.25x
Shard
2.85x
Hydraulic Pump Maintenance
A mechanical surgery procedure designed to repair an androids internal hydraulic pump.
All of these are required:
Operate on hydraulic pump engine (target chest)
The skin must be open
The organs must be cut
The bone must be sawed
The patient must be lying down
However:
The operation site must not be obstructed by clothing
Tool
Speed Multiplier
Crowbar
0.8x
Scalpel
1.5x
Energy sword
2x
Knife
3.25x
Shard
3.85x
Add dental implant
Implant a pill into a patient's teeth.
All of these are required:
Operate on mouth (target mouth)
The skin must be open
The bone must be drilled
The patient must be lying down
The mouth must have teeth
However:
The blood vessels must not be unclamped
The operation site must not be obstructed by clothing
Tool
Speed Multiplier
Pill
1x
Disarticulation (Amputation)
Sever a limb from a patient's body.
All of these are required:
The skin must be open
The bone must be sawed
The patient must be lying down
However:
The blood vessels must not be unclamped
The operation site must not be obstructed by clothing
The limb must not be cybernetic
Tool
Speed Multiplier
Amputation shears
0.33x
Saw
1x
Scalpel
1x
Arm blade
1.25x
Serrated bone shovel
1.33x
Fire axe
2x
Hatchet
2.5x
Butcher's cleaver
4x
Surplus machete
1.25x
Augmentation
Replace a patient's limb with a robotic or prosthetic one.
All of these are required:
The skin must be open
The patient must be lying down
However:
The operation site must not be obstructed by clothing
Tool
Speed Multiplier
Limb
1x
Androtomy (Dissection and Autopsy)
Perform a detailed analysis of a deceased patient's body.
All of these are required:
Operate on chest (target chest)
The skin must be open
The patient must be lying down
The patient must be deceased
The patient must not have been autopsied prior
However:
The limb must not be cybernetic
Tool
Speed Multiplier
Autopsy scanner
1x
Hemodialysis (Blood Filtration)
Remove unwanted chemicals from a patient's bloodstream.
All of these are required:
Operate on chest (target chest)
The skin must be open
The patient must be lying down
The patient must not be husked
However:
The blood vessels must not be unclamped
The operation site must not be obstructed by clothing
The limb must not be cybernetic
Tool
Speed Multiplier
Blood filter
1x
Neurosurgery (Brain Surgery)
Repair a patient's damaged brain tissue to restore cognitive function.
All of these are required:
Operate on brain (target head)
The skin must be open
The bone must be sawed
The patient must be lying down
However:
The blood vessels must not be unclamped
The operation site must not be obstructed by clothing
The organ must not be cybernetic
Tool
Speed Multiplier
Hemostat
1.05x
Screwdriver
2.85x
Pen
6.67x
Cavity implant
Implant an item into a patient's body cavity.
All of these are required:
Operate on chest (target chest)
The skin must be open
The organs must be cut
The chest cavity must be opened wide
The patient must be lying down
However:
The operation site must not be obstructed by clothing
Tool
Speed Multiplier
Any item
1x
Clamp bleeders
Clamp bleeding blood vessels in the patient's body to prevent blood loss. Causes "vessels clamped" surgical state.
All of these are required:
The skin must be open
The blood vessels must be unclamped
The patient must be lying down
However:
The operation site must not be obstructed by clothing
The limb must not be cybernetic
Tool
Speed Multiplier
Hemostat
1x
Cutters
1.67x
Package wrapper
2.85x
Cable coil
6.67x
Debridement
Remove infected or necrotic flesh from a patient's wound to promote healing.
All of these are required:
The limb must have a second degree or worse burn
The patient must be lying down
However:
The operation site must not be obstructed by clothing
Tool
Speed Multiplier
Hemostat
1x
Scalpel
1.25x
Saw
1.66x
Cutters
2.5x
Detach Wooden Limb (Amputation)
Sever a limb from a patient's body.
All of these are required:
The patient must be lying down
The limb must be wooden
However:
The blood vessels must not be unclamped
The operation site must not be obstructed by clothing
Tool
Speed Multiplier
Saw
1x
Serrated bone shovel
1x
Fire axe
1.15x
Hatchet
1.33x
Scalpel
4x
Surplus machete
1.25x
Dissassembly (Amputation)
Sever a limb from a patient's body.
All of these are required:
The skin must be open
The patient must be lying down
Any one of these is required:
If operating on the head, the bone MUST be sawed
Otherwise, the state of the bone doesn't matter
However:
The blood vessels must not be unclamped
The operation site must not be obstructed by clothing
The limb must not be organic
Tool
Speed Multiplier
Wrench
1x
Crowbar
1x
Scalpel
2x
Saw
2x
Discard skull debris
Clear away bone fragments and debris from a patient's cranial fissure in preparation for repair.
All of these are required:
The cranium must be fractured
The patient must be lying down
However:
The operation site must not be obstructed by clothing
Tool
Speed Multiplier
Hemostat
1x
Cutters
2.5x
Screwdriver
2.5x
Drill limb bone
Drill through a patient's bones. Causes "bone drilled" surgical state.
All of these are required:
The skin must be open
The patient must be lying down
However:
The bone must be intact
The operation site must not be obstructed by clothing
The limb must not be cybernetic
Tool
Speed Multiplier
Drill
1x
Hand drill
1.25x
Mining drill
1.67x
Screwdriver
4x
Spoon
5x
Any sharp pointed item with decent force
6.67x
Repair Auditory Microphones (Hearing Repair)
Repair a patient's damaged ears to restore hearing.
All of these are required:
Operate on auditory sensors (target chest)
The skin must be open
The patient must be lying down
However:
The blood vessels must not be unclamped
The operation site must not be obstructed by clothing
If the limb has bones, they must be intact
If the limb has bones, they must be intact
Tool
Speed Multiplier
Multitool
1.15x
Screwdriver
4.85x
Pen
6.67x
Ototomy (Ear surgery)
Repair a patient's damaged ears to restore hearing.
All of these are required:
Operate on ears (target head)
The skin must be open
The patient must be lying down
However:
The blood vessels must not be unclamped
The operation site must not be obstructed by clothing
The organ must not be cybernetic
If the limb has bones, they must be intact
Tool
Speed Multiplier
Hemostat
1.05x
Screwdriver
2.25x
Pen
4x
Nutrient Reserve Expulsion (Excise Fat)
Remove excess fat from a patient's body.
All of these are required:
Operate on chest (target chest)
The skin must be open
The patient must be lying down
The patient must have excess fat to remove
However:
The blood vessels must not be unclamped
The operation site must not be obstructed by clothing
The limb must not be organic
Tool
Speed Multiplier
Wrench
1.05x
Crowbar
1.05x
Serrated bone shovel
1.33x
Energy sword
1.33x
Saw
1.67x
Hatchet
3.33x
Knife
3.33x
Scalpel
4x
Any sharp edged item
5x
Lobectomy (Lung Surgery)
Perform repairs to a patient's damaged lung by excising the most damaged lobe. This procedure can only be performed once per organ.
All of these are required:
Operate on lungs (target chest)
The skin must be open
The organs must be cut
The bone must be sawed
The patient must be lying down
The organ must be moderately damaged
However:
The operation site must not be obstructed by clothing
The organ must not be cybernetic
The organ must not have been surgically repaired prior
Tool
Speed Multiplier
Scalpel
1.05x
Energy sword
1.5x
Knife
2.25x
Shard
2.85x
Lipoplasty (Excise Fat)
Remove excess fat from a patient's body.
All of these are required:
Operate on chest (target chest)
The skin must be open
The patient must be lying down
The patient must have excess fat to remove
However:
The blood vessels must not be unclamped
The operation site must not be obstructed by clothing
The limb must not be cybernetic
Tool
Speed Multiplier
Saw
1x
Scalpel
1.25x
Serrated bone shovel
1.33x
Energy sword
1.33x
Hatchet
3.33x
Knife
3.33x
Any sharp edged item
5x
Corectomy (Extract Core)
Remove the core from a slime.
All of these are required:
Operate on a deceased slime
Operate on chest (target chest)
The skin must be cut or opened
Tool
Speed Multiplier
Hemostat
1x
Crowbar
1x
Vitrectomy (Eye Surgery)
Repair a patient's damaged eyes to restore vision.
All of these are required:
Operate on eyes (target eyes)
The skin must be open
The patient must be lying down
However:
The blood vessels must not be unclamped
The operation site must not be obstructed by clothing
The organ must not be cybernetic
If the limb has bones, they must be intact
Tool
Speed Multiplier
Hemostat
1.05x
Screwdriver
2.25x
Pen
4x
Feature manipulation
Manipulate features of the patient, such as a moth's wings or a lizard's tail.
All of these are required:
The skin must be open
The bone must be sawed
The patient must be lying down
However:
The blood vessels must not be unclamped
The operation site must not be obstructed by clothing
The limb must not be cybernetic
Tool
Speed Multiplier
Hemostat
1x
Crowbar
1.8x
Fork
2.85x
Organ
1x
Fix limb bone
Repair a patient's cut or broken bones. Clears "bone sawed" and "bone drilled" surgical states.
All of these are required:
The skin must be open
The patient must be lying down
The limb must have bones
The bone must be sawed or drilled
However:
The operation site must not be obstructed by clothing
Use a defibrillator to shock a patient's brain back to life.
All of these are required:
Operate on head (target head)
The skin must be open
The bone must be sawed
The patient must be lying down
The patient must be deceased
The patient must be in a revivable state
However:
The operation site must not be obstructed by clothing
Tool
Speed Multiplier
Defibrillator paddles
1x
Shock touch
1x
Stun baton
1.33x
Energy gun
1.67x
Structural Repairs (Tend Wounds)
Perform superficial repairs that focuses on fixing the patients chassis and physical frame.
All of these are required:
Operate on chest (target chest)
The patient must be lying down
The patient must have denting or heat damage
The skin must be cut or opened
However:
The patient must not be robotic
Tool
Speed Multiplier
Welder
1x
Cable coil
1x
Screwdriver
1.5x
Cutters
1.67x
System Failure Analysis (Dissection and Autopsy)
Perform a detailed analysis of a robotic patient's deactivated systems.
All of these are required:
Operate on chest (target chest)
The skin must be open
The patient must be lying down
The patient must be deceased
The patient must not have been autopsied prior
However:
The limb must not be organic
Tool
Speed Multiplier
Autopsy scanner
1x
Tend Wounds
Perform superficial wound care on a patient's bruises and burns.
All of these are required:
Operate on chest (target chest)
The patient must be lying down
The patient must have brute or burn damage
The skin must be cut or opened
However:
The patient must not be robotic
Tool
Speed Multiplier
Hemostat
1x
Screwdriver
1.5x
Cutters
1.67x
Pen
1.8x
Unclamp bleeders
Unclamp blood vessels in the patient's body to allow blood flow again. Clears "vessels clamped" surgical state.
All of these are required:
The skin must be open
The blood vessels must be clamped
The patient must be lying down
The limb must have blood vessels
However:
The operation site must not be obstructed by clothing
The limb must not be cybernetic
Tool
Speed Multiplier
Hemostat
1x
Cutters
1.67x
Package wrapper
2.85x
Cable coil
6.67x
Unscrew shell
Unscrew the shell of a mechanical patient to access its internals. Causes "cut skin" surgical state.
All of these are required:
The patient must be lying down
You may optionally:
A surgeon may perform this on themselves
However:
The skin must be intact
The operation site must not be obstructed by clothing
The limb must not be organic
Tool
Speed Multiplier
Screwdriver
1x
Scalpel
1.33x
Knife
2x
Any sharp item
10x
Unwrench endoskeleton
Unwrench a mechanical patient's endoskeleton to access its internals. Clears "bone sawed" surgical state.
All of these are required:
The skin must be open
The patient must be lying down
You may optionally:
A surgeon may perform this on themselves
However:
The bone must be intact
The operation site must not be obstructed by clothing
The limb must not be organic
Tool
Speed Multiplier
Wrench
1x
Retractor
1.33x
Widen chest cavity
Widen a patient's chest cavity to allow for implanting of larger items.
All of these are required:
Operate on chest (target chest)
The skin must be open
The organs must be cut
The patient must be lying down
However:
The chest cavity must not be opened wide
The operation site must not be obstructed by clothing
Tool
Speed Multiplier
Retractor
1x
Crowbar
1.5x
Wrench endoskeleton
Wrench a mechanical patient's endoskeleton back into place. Clears "bone sawed" surgical state.
All of these are required:
The skin must be open
The bone must be sawed
The patient must be lying down
The limb must have bones
You may optionally:
A surgeon may perform this on themselves
However:
The operation site must not be obstructed by clothing
The limb must not be organic
Tool
Speed Multiplier
Wrench
1x
Retractor
1.33x
Apply plastic
Apply plastic to a patient's face to to allow for greater customization in following plastic surgery.
All of these are required:
The skin must be open
The patient must be lying down
However:
The blood vessels must not be unclamped
Plastic must not be applied
The operation site must not be obstructed by clothing
Tool
Speed Multiplier
Plastic
1x
Neural Brainwashing (Brainwash)
A surgical procedure which directly implants a directive into the patient's brain, making it their absolute priority. It can be cleared using a mindshield implant.
All of these are required:
Operate on brain (target head)
The skin must be open
The organs must be cut
The bone must be sawed
The patient must be lying down
However:
The operation site must not be obstructed by clothing
The organ must not be cybernetic
Tool
Speed Multiplier
Hemostat
1.15x
Cutters
2x
Package wrapper
2.85x
Cable coil
6.67x
Encephalofractoplasty (Cortex Folding)
A biological upgrade which folds a patient's cerebral cortex into a fractal pattern, increasing neural density and flexibility.
All of these are required:
Operate on head (target head)
The skin must be open
The organs must be cut
The bone must be sawed
The patient must be lying down
However:
The operation site must not be obstructed by clothing
The limb must not be cybernetic
The patient must not have undergone Encephalofractoplasty (Cortex Folding) OR Encephalopremoplasty (Cortex Imprinting) prior
Tool
Speed Multiplier
Hands
1x
Wetware OS Labyrinthian Programming (Cortex Folding)
Reprogram a robotic patient's neural network in a downright eldritch programming language, giving space to non-standard neural patterns.
All of these are required:
Operate on head (target head)
The skin must be open
The organs must be cut
The bone must be sawed
The patient must be lying down
However:
The operation site must not be obstructed by clothing
The limb must not be organic
The patient must not have undergone Wetware OS Labyrinthian Programming (Cortex Folding) OR Wetware OS Ver 2.0 (Cortex Imprinting) prior
Tool
Speed Multiplier
Hands
1x
Neuropathing Reinforcement (Cortex Folding)
Reprogram a robotic patient's neural network in a downright eldritch programming language, giving space to non-standard neural patterns.
All of these are required:
Operate on chest (target chest)
The skin must be open
The organs must be cut
The bone must be sawed
The patient must be lying down
However:
The operation site must not be obstructed by clothing
The patient must not have undergone Neuropathing Reinforcement (Cortex Folding) OR Anti-Cascade 2.0 (Cortex Imprinting) prior
Tool
Speed Multiplier
Hands
1x
Encephalopremoplasty (Cortex Imprinting)
A biological upgrade which carves a patient's cerebral cortex into a self-imprinting pattern, increasing neural density and resilience.
All of these are required:
Operate on head (target head)
The skin must be open
The organs must be cut
The bone must be sawed
The patient must be lying down
However:
The operation site must not be obstructed by clothing
The limb must not be cybernetic
The patient must not have undergone Encephalofractoplasty (Cortex Folding) OR Encephalopremoplasty (Cortex Imprinting) prior
Tool
Speed Multiplier
Hands
1x
Wetware OS Ver 2.0 (Cortex Imprinting)
Update a robotic patient's operating system to a "newer version", improving overall performance and resilience. Shame about all the adware.
All of these are required:
Operate on head (target head)
The skin must be open
The organs must be cut
The bone must be sawed
The patient must be lying down
However:
The operation site must not be obstructed by clothing
The limb must not be organic
The patient must not have undergone Wetware OS Labyrinthian Programming (Cortex Folding) OR Wetware OS Ver 2.0 (Cortex Imprinting) prior
Tool
Speed Multiplier
Hands
1x
Anti-Cascade 2.0 (Cortex Imprinting)
Update a robotic patient's underlying operating system to a "newer version", improving overall performance and resilience. Shame about all the adware.
All of these are required:
Operate on chest (target chest)
The skin must be open
The organs must be cut
The bone must be sawed
The patient must be lying down
However:
The operation site must not be obstructed by clothing
The patient must not have undergone Neuropathing Reinforcement (Cortex Folding) OR Anti-Cascade 2.0 (Cortex Imprinting) prior
Tool
Speed Multiplier
Hands
1x
Aggression Suppression Programming (Pacification)
Install malware which permanently inhibits the aggression programming of the patient's neural network, making the patient unwilling to cause direct harm.
All of these are required:
Operate on brain (target head)
The skin must be open
The bone must be sawed
The patient must be lying down
However:
The blood vessels must not be unclamped
The operation site must not be obstructed by clothing
The organ must not be organic
Tool
Speed Multiplier
Multitool
1x
Hemostat
2.85x
Screwdriver
2.85x
Pen
6.67x
Wetware OS Destructive Defragmentation (Lobotomy)
An invasive surgical procedure which guarantees removal of almost all brain traumas, but might cause another permanent trauma in return.
All of these are required:
Operate on brain (target head)
The skin must be open
The bone must be sawed
The patient must be lying down
However:
The blood vessels must not be unclamped
The operation site must not be obstructed by clothing
The organ must not be organic
Tool
Speed Multiplier
Multitool
1.15x
Energy sword
1.85x
Knife
2.85x
Shard
4x
Any sharp edged item
5x
Experimental Androtomy (Experimental Dissection and Autopsy)
An experimental surgical procedure that dissects bodies in exchange for research points at ancient R&D consoles.
All of these are required:
Operate on chest (target chest)
The patient must be lying down
The patient must be deceased
The patient must not have been dissected prior
The skin must be cut or opened
Tool
Speed Multiplier
Autopsy scanner
1x
Scalpel
1.66x
Knife
5x
Shard
10x
Xanthoneuroplasty (Grounded Nerves)
Reroute a patient's nerves to act as grounding rods, protecting them from electrical shocks.
All of these are required:
Operate on chest (target chest)
The skin must be open
The organs must be cut
The bone must be sawed
The patient must be lying down
However:
The operation site must not be obstructed by clothing
The limb must not be cybernetic
The patient must not have undergone Symneurodesis (Spliced Nerves) OR Xanthoneuroplasty (Grounded Nerves) prior
Tool
Speed Multiplier
Hands
1x
System Shock Dampening (Grounded Nerves)
Install grounding rods into a robotic patient's nervous system, protecting it from electrical shocks.
All of these are required:
Operate on chest (target chest)
The skin must be open
The organs must be cut
The bone must be sawed
The patient must be lying down
However:
The operation site must not be obstructed by clothing
The limb must not be organic
The patient must not have undergone System Automatic Reset Subroutine (Spliced Nerves) OR System Shock Dampening (Grounded Nerves) prior
Tool
Speed Multiplier
Hands
1x
Reinforced Capacitors (Grounded Nerves)
Install an additional capacitor bank designed to abdorb electrical shocks.
All of these are required:
Operate on chest (target chest)
The skin must be open
The organs must be cut
The bone must be sawed
The patient must be lying down
However:
The operation site must not be obstructed by clothing
The patient must not have undergone Reinforced Servos (Spliced Nerves) OR Reinforced Capacitors (Grounded Nerves) prior
Tool
Speed Multiplier
Hands
1x
Bionecroplasty (Necrotic Revival)
An experimental procedure which induces the growth of a Romerol tumor inside the patient's brain.
All of these are required:
The skin must be open
The bone must be sawed
The patient must be lying down
The limb must have a brain present
Any one of these is required:
The patient or tool must contain >1u Rezadone
The patient or tool must contain >1u Zombie Powder
However:
The blood vessels must not be unclamped
The operation site must not be obstructed by clothing
The limb must not be organic
The limb must not already have a Romerol tumor
Tool
Speed Multiplier
Syringe
1x
Pen
3.33x
Sleeper Agent Implantation (Brainwash)
A surgical procedure which directly implants a directive into the patient's brain, making it their absolute priority. It can be cleared using a mindshield implant.
All of these are required:
Operate on brain (target head)
The skin must be open
The organs must be cut
The bone must be sawed
The patient must be lying down
However:
The operation site must not be obstructed by clothing
The organ must not be cybernetic
Tool
Speed Multiplier
Hemostat
1.15x
Cutters
2x
Package wrapper
2.85x
Cable coil
6.67x
Sleeper Agent Programming (Brainwash)
A surgical procedure which directly implants a directive into the patient's brain, making it their absolute priority. It can be cleared using a mindshield implant.
All of these are required:
Operate on brain (target head)
The skin must be open
The organs must be cut
The bone must be sawed
The patient must be lying down
However:
The operation site must not be obstructed by clothing
The organ must not be organic
Tool
Speed Multiplier
Multitool
1.15x
Hemostat
2x
Cutters
2x
Package wrapper
2.85x
Cable coil
6.67x
Lobotomy (Lobotomy)
An invasive surgical procedure which guarantees removal of almost all brain traumas, but might cause another permanent trauma in return.
All of these are required:
Operate on brain (target head)
The skin must be open
The bone must be sawed
The patient must be lying down
However:
The blood vessels must not be unclamped
The operation site must not be obstructed by clothing
The organ must not be cybernetic
Tool
Speed Multiplier
Scalpel
1.15x
Energy sword
0.55x
Knife
2.85x
Shard
4x
Any sharp edged item
5x
Myovasculoplasty (Muscled Veins)
Add a muscled membrane to a patient's veins, allowing them to pump blood without a heart.
All of these are required:
Operate on chest (target chest)
The skin must be open
The organs must be cut
The bone must be sawed
The patient must be lying down
However:
The operation site must not be obstructed by clothing
The limb must not be cybernetic
The patient must not have undergone Symvasculodesis (Vein Threading) OR Myovasculoplasty (Muscled Veins) prior
Tool
Speed Multiplier
Hands
1x
Hydraulics Redundancy Subroutine (Muscled Veins)
Add redundancies to a robotic patient's hydraulic system, allowing it to pump fluids without an engine or pump.
All of these are required:
Operate on chest (target chest)
The skin must be open
The organs must be cut
The bone must be sawed
The patient must be lying down
However:
The operation site must not be obstructed by clothing
The limb must not be organic
The patient must not have undergone Hydraulics Routing Optimization (Threaded Veins) OR Hydraulics Redundancy Subroutine (Muscled Veins) prior
Tool
Speed Multiplier
Hands
1x
Hydraulics Redundancy Subroutine (Muscled Veins)
Add redundancies to a robotic patient's hydraulic system, allowing it to pump fluids without an engine or pump.
All of these are required:
Operate on chest (target chest)
The skin must be open
The organs must be cut
The bone must be sawed
The patient must be lying down
However:
The operation site must not be obstructed by clothing
The patient must not have undergone Hydraulics Redundancy Subroutine (Muscled Veins) prior
Tool
Speed Multiplier
Hands
1x
Paxopsy (Pacification)
A surgical procedure which permanently inhibits the aggression center of the brain, making the patient unwilling to cause direct harm.
All of these are required:
Operate on brain (target head)
The skin must be open
The bone must be sawed
The patient must be lying down
However:
The blood vessels must not be unclamped
The operation site must not be obstructed by clothing
The organ must not be cybernetic
Tool
Speed Multiplier
Hemostat
1x
Screwdriver
2.85x
Pen
6.67x
Pteroplasty (Wing Repair)
A surgical procedure that repairs damaged wings using Synthflesh.
All of these are required:
Operate on moth wings (target chest)
The skin must be open
The patient must be lying down
The wings must be burnt
The patient must be dosed with >=5u Synthflesh
However:
The blood vessels must not be unclamped
The operation site must not be obstructed by clothing
If the limb has bones, they must be intact
Tool
Speed Multiplier
Hemostat
1.15x
Screwdriver
2.85x
Pen
6.67x
Neural Reprogramming (Brainwash)
Install malware which directly implants a directive into the robotic patient's operating system, making it their absolute priority. It can be cleared using a mindshield implant.
All of these are required:
Operate on brain (target head)
The skin must be open
The organs must be cut
The bone must be sawed
The patient must be lying down
However:
The operation site must not be obstructed by clothing
The organ must not be organic
Tool
Speed Multiplier
Multitool
1.15x
Hemostat
2x
Cutters
2x
Package wrapper
2.85x
Cable coil
6.67x
Arthroplasty (Ligament Hooks)
Reshape a patient's ligaments to allow limbs to be manually reattached if severed - at the cost of making them easier to detach.
All of these are required:
Operate on chest (target chest)
The skin must be open
The organs must be cut
The bone must be sawed
The patient must be lying down
However:
The operation site must not be obstructed by clothing
The limb must not be cybernetic
The patient must not have undergone Arthroplasty (Ligament Hooks) OR Arthrorrhaphy (Ligament Reinforcement) prior
Tool
Speed Multiplier
Hands
1x
Anchor Point Snaplocks (Ligament Hooks)
Refactor a robotic patient's limb joints to allow for rapid deatchment, allowing limbs to be manually reattached if severed - at the cost of making them easier to detach as well.
All of these are required:
Operate on chest (target chest)
The skin must be open
The organs must be cut
The bone must be sawed
The patient must be lying down
However:
The operation site must not be obstructed by clothing
The limb must not be organic
The patient must not have undergone Anchor Point Snaplocks (Ligament Hooks) OR Anchor Point Reinforcement (Ligament Reinforcement) prior
Tool
Speed Multiplier
Hands
1x
Symneurodesis (Spliced Nerves)
Splice a patient's nerves together to make them more resistant to stuns.
All of these are required:
Operate on chest (target chest)
The skin must be open
The organs must be cut
The bone must be sawed
The patient must be lying down
However:
The operation site must not be obstructed by clothing
The limb must not be cybernetic
The patient must not have undergone Symneurodesis (Spliced Nerves) OR Xanthoneuroplasty (Grounded Nerves) prior
Tool
Speed Multiplier
Hands
1x
System Automatic Reset Subroutine (Spliced Nerves)
Upgrade a robotic patient's automatic systems, allowing it to better resist stuns.
All of these are required:
Operate on chest (target chest)
The skin must be open
The organs must be cut
The bone must be sawed
The patient must be lying down
However:
The operation site must not be obstructed by clothing
The limb must not be organic
The patient must not have undergone System Automatic Reset Subroutine (Spliced Nerves) OR System Shock Dampening (Grounded Nerves) prior
Tool
Speed Multiplier
Hands
1x
Reinforced Servos (Spliced Nerves)
Upgrade a synthetic patient's movement servos, allowing it to better resist stuns.
All of these are required:
Operate on chest (target chest)
The skin must be open
The organs must be cut
The bone must be sawed
The patient must be lying down
However:
The operation site must not be obstructed by clothing
The patient must not have undergone Reinforced Servos (Spliced Nerves) OR Reinforced Capacitors (Grounded Nerves) prior
Tool
Speed Multiplier
Hands
1x
Arthrorrhaphy (Ligament Reinforcement)
Strengthen a patient's ligaments to make dismemberment more difficult, at the cost of making nerve connections easier to interrupt.
All of these are required:
Operate on chest (target chest)
The skin must be open
The organs must be cut
The bone must be sawed
The patient must be lying down
However:
The operation site must not be obstructed by clothing
The limb must not be cybernetic
The patient must not have undergone Arthroplasty (Ligament Hooks) OR Arthrorrhaphy (Ligament Reinforcement) prior
Tool
Speed Multiplier
Hands
1x
Anchor Point Reinforcement (Ligament Reinforcement)
Reinforce a robotic patient's limb joints to prevent dismemberment, at the cost of making nerve connections easier to interrupt.
All of these are required:
Operate on chest (target chest)
The skin must be open
The organs must be cut
The bone must be sawed
The patient must be lying down
However:
The operation site must not be obstructed by clothing
The limb must not be organic
The patient must not have undergone Anchor Point Snaplocks (Ligament Hooks) OR Anchor Point Reinforcement (Ligament Reinforcement) prior
Tool
Speed Multiplier
Hands
1x
Anchor Point Reinforcement (Ligament Reinforcement)
Reinforce a robotic patient's limb joints to prevent dismemberment, at the cost of making nerve connections easier to interrupt.
All of these are required:
Operate on chest (target chest)
The skin must be open
The organs must be cut
The bone must be sawed
The patient must be lying down
However:
The operation site must not be obstructed by clothing
The patient must not have undergone Anchor Point Reinforcement (Ligament Reinforcement) prior
Tool
Speed Multiplier
Hands
1x
Structural Repairs (Tend Wounds)+
Perform superficial repairs that focuses on fixing the patients chassis and physical frame.
All of these are required:
Operate on chest (target chest)
The patient must be lying down
The patient must have denting or heat damage
The skin must be cut or opened
However:
The patient must not be robotic
Tool
Speed Multiplier
Welder
1x
Cable coil
1x
Screwdriver
1.5x
Cutters
1.67x
Structural Repairs (Tend Wounds)++
Perform superficial repairs that focuses on fixing the patients chassis and physical frame.
All of these are required:
Operate on chest (target chest)
The patient must be lying down
The patient must have denting or heat damage
The skin must be cut or opened
However:
The patient must not be robotic
Tool
Speed Multiplier
Welder
1x
Cable coil
1x
Screwdriver
1.5x
Cutters
1.67x
Tend Wounds+
Perform superficial wound care on a patient's bruises and burns.
All of these are required:
Operate on chest (target chest)
The patient must be lying down
The patient must have brute or burn damage
The skin must be cut or opened
However:
The patient must not be robotic
Tool
Speed Multiplier
Hemostat
1x
Screwdriver
1.5x
Cutters
1.67x
Pen
1.8x
Tend Wounds++
Perform superficial wound care on a patient's bruises and burns.
All of these are required:
Operate on chest (target chest)
The patient must be lying down
The patient must have brute or burn damage
The skin must be cut or opened
However:
The patient must not be robotic
Tool
Speed Multiplier
Hemostat
1x
Screwdriver
1.5x
Cutters
1.67x
Pen
1.8x
Advanced Tend Wounds
Perform superficial wound care on a patient's bruises and burns.
All of these are required:
Operate on chest (target chest)
The patient must be lying down
The patient must have brute or burn damage
The skin must be cut or opened
However:
The patient must not be robotic
Tool
Speed Multiplier
Hemostat
1x
Screwdriver
1.5x
Cutters
1.67x
Pen
1.8x
Advanced Tend Wounds+
Perform superficial wound care on a patient's bruises and burns.
All of these are required:
Operate on chest (target chest)
The patient must be lying down
The patient must have brute or burn damage
The skin must be cut or opened
However:
The patient must not be robotic
Tool
Speed Multiplier
Hemostat
1x
Screwdriver
1.5x
Cutters
1.67x
Pen
1.8x
Advanced Tend Wounds++
Perform superficial wound care on a patient's bruises and burns.
All of these are required:
Operate on chest (target chest)
The patient must be lying down
The patient must have brute or burn damage
The skin must be cut or opened
However:
The patient must not be robotic
Tool
Speed Multiplier
Hemostat
1x
Screwdriver
1.5x
Cutters
1.67x
Pen
1.8x
Advanced Structural Repair
Perform superficial wound care on a patient's bruises and burns.
All of these are required:
Operate on chest (target chest)
The patient must be lying down
The patient must have brute or burn damage
The skin must be cut or opened
However:
The patient must not be robotic
Tool
Speed Multiplier
Hemostat
1x
Screwdriver
1.5x
Cutters
1.67x
Pen
1.8x
Advanced Structural Repair+
Perform superficial wound care on a patient's bruises and burns.
All of these are required:
Operate on chest (target chest)
The patient must be lying down
The patient must have brute or burn damage
The skin must be cut or opened
However:
The patient must not be robotic
Tool
Speed Multiplier
Hemostat
1x
Screwdriver
1.5x
Cutters
1.67x
Pen
1.8x
Advanced Structural Repair++
Perform superficial wound care on a patient's bruises and burns.
All of these are required:
Operate on chest (target chest)
The patient must be lying down
The patient must have brute or burn damage
The skin must be cut or opened
However:
The patient must not be robotic
Tool
Speed Multiplier
Hemostat
1x
Screwdriver
1.5x
Cutters
1.67x
Pen
1.8x
Symvasculodesis (Vein Threading)
Weave a patient's veins into a reinforced mesh, reducing blood loss from injuries.
All of these are required:
Operate on chest (target chest)
The skin must be open
The organs must be cut
The bone must be sawed
The patient must be lying down
However:
The operation site must not be obstructed by clothing
The limb must not be cybernetic
The patient must not have undergone Symvasculodesis (Vein Threading) OR Myovasculoplasty (Muscled Veins) prior
Tool
Speed Multiplier
Hands
1x
Hydraulics Routing Optimization (Threaded Veins)
Optimize the routing of a robotic patient's hydraulic system, reducing fluid loss from leaks.
All of these are required:
Operate on chest (target chest)
The skin must be open
The organs must be cut
The bone must be sawed
The patient must be lying down
However:
The operation site must not be obstructed by clothing
The limb must not be organic
The patient must not have undergone Hydraulics Routing Optimization (Threaded Veins) OR Hydraulics Redundancy Subroutine (Muscled Veins) prior
Tool
Speed Multiplier
Hands
1x
Viroplasty (Viral Bonding)
A surgical procedure that forces a symbiotic relationship between a virus and its host. The patient will be completely immune to the effects of the virus, but will carry and spread it to others.
All of these are required:
Operate on chest (target chest)
The skin must be open
The organs must be cut
The patient must be lying down
The patient must have a virus to bond
The patient must be dosed with >=1u Spaceacillin
The patient must be dosed with >=1u Virus Food
The patient must be dosed with >=1u Formaldehyde
However:
The operation site must not be obstructed by clothing