User:Zergspower/Sandbox: Difference between revisions
Zergspower (talk | contribs) (Initial) |
Zergspower (talk | contribs) (ho-boy surgery refactor) |
||
| Line 1: | Line 1: | ||
All surgery requires a set of medical tools, typically found in the [[Operating Theatre]], along with an operating table. | |||
= Surgical Tools = | |||
[[Medical_items#Surgical_Tools|Information about most tools used in surgery can be found here.]] | |||
= | ==Surgery Speed and Failure== | ||
While every operation has an intended tool, you are not limited to it alone. Every operation has a list of alternative tools you can use instead. | |||
Beside each tool is a multiplier which indicates how much of a penalty to speed you are given for using the supplied tool. | |||
These multipliers stack multiplicatively with those from operating site or chemicals (see [[#Beginning of any Operation|Beginning of any Operation]]).<br> | |||
Note, speed penalty <b>is capped to 2x the base time</b> the step would have taken. | |||
A step that takes 10 seconds would cap at 20 seconds, for example. | |||
However, <i>every second after that cap will instead add 1 percentage point into the odds of a failure</i>. | |||
Failing may cause extra damage or other effects. | |||
So for example: | |||
* Say a surgery step takes 10 seconds by default, but you use a pen (2.5x) instead of a hemostat and do it on the floor (2x) instead of a surgery table. | |||
* Now the surgery is slowed to 50 seconds, but it's capped to 20 seconds. | |||
* Those 30 extra seconds that were removed is now your chance to fail the operation. | |||
* Result: The step takes 20 seconds and has a 30% chance to fail. | |||
= The Operation Process = | |||
Step 1: Undress the part of the patient that needs surgery. You can do this by dragging them onto yourself, and then clicking the clothes you want to remove from them in the pop-up. Alternatively, some clothes like jumpsuits can be adjusted out of the way, to save yourself some time. | |||
* '''Important:''' The uniform the patient is wearing usually covers both legs, arms, groin and torso. Helmets, eyewear and masks always obscure the eyes, make sure to remove them if working on the eyes. | |||
Step 2: [[File:Surgery table.png|Operating Table]] Place the patient onto the '''operating table'''. Do this doing a {{Grab}} on the patient. Then left click the operating table to place the patient on it. You can also {{Rightclick}} shove a person onto the table and tell them to rest, though they might not appreciate this. | |||
* If there is no operating table, you can use: '''[[Machines#Lifeform_Stasis_Unit|Stasis bed]]''' (1.15x), '''any table''' (1.25x), '''any bed''' (1.5x), ask them to lie '''on the floor''' (2x). The [[#Surgery Speed and Failure|speed]] of completing every step will be reduced. | |||
Step 2.1 [[File:LongIslandIcedTea.png|Ethanol]] (Optional) Splash on, spray or apply a patch with a reagent like [[Guide_to_chemistry#Miner's Salve|'''Miner's Salve''']] (0.9x), [[Guide_to_chemistry#Sterilizine|'''Sterilizine''']] 0.8x), [[Guide_to_food_and_drinks#Drinks|'''alcoholic drinks''']] (up to ~0.5x*), or [[Beekeeping#The_fruits_of_our_labour|'''Honey''']] (0.6x) for faster surgery speed. | |||
*The stronger the alcohol, the more effective! The formula is: (booze power / 650). For example: Ethanol gives ~0.9x surgery speed, Manly Dorf ~0.85x, Bacchus' Blessing ~0.5x. | |||
Step 2.2: [[File:N2Otank.png|Sleeping Agent]] (Optional) Use a '''tank of anesthetic''' and a '''breath mask''' to make your patient sleep. This way patient won't experience agonizing pain, decreasing its [[mood]]. | |||
Step 3: [[File:Drapes.png|Drapes]] [[File:Bedsheet.png|Bedsheet]] Place '''drapes''' or '''bedsheet''' over the part of body you are operating. | |||
* If you done step 1 wrong, it will tell you that you must remove clothing first. If you continue without fixing, you will stab your patient instead of doing surgery. | |||
Step 4: Turn off {{Combat_Mode}}. Pro tip: {{Rightclick}} will make you fail every surgery step on purpose. | |||
Step 5: [[File:Hud-target.gif|Target]] '''Aim''' at the appropriate body part (important!). | |||
Step 6: {{LeftclickCmodeoff}} [[File:Scalpel.png|Scalpel]] '''Begin surgery''' (see the steps below!). | |||
To get to the operation you want to complete, it will require you get the patient to the necessary state*. | |||
For example, an overwhelming majority of surgeries will require the patient's skin be opened first. | |||
To open the skin you'll need to complete "Retract skin" first, and to be able to complete "Retract skin", you will need to "Make skin incision". | |||
More complicated surgeries require more complicated states, such as sawing bones. | |||
While a patient's undergoing surgery, they will slowly lose blood. Try not to dawdle! | |||
* | * Note: Some patients you receive will be in a state already ready for suregry! Species like [[Plasmamen]] have no skin, so you have nothing to make an incision in. You can simply skip that step! | ||
Step 7: '''Complete your surgery''' | |||
After getting to the state required, you can do whatever operation you intended. Congratulations, you just did surgery! That wasn't so bad, right? | |||
Step 7.5: Repeat! | |||
Feel free to do any other operation while the patient is cut open. States don't automatically get cleared after you're done! You can save yourself a lot of time this way. | |||
Step 8: '''Close the patient''' | |||
After all is said and done, don't forget to cauterize or suture the operated bodypart! The patient will continue to bleed if you don't. | |||
And you're done! Send the patient out with a lollipop and a smile. | |||
= Operations = | |||
What follows is a full list of every operation that you can undergo. | |||
<b>Green</b> operations are mechanical surgeries and will only work on cybernetic patients. | |||
<b>Purple</b> operations are locked - typically behind technology from science, but sometimes behind rare or traitorous surgical disks. They cannot be undergone without first being loaded into an operating computer. | |||
{{Autowiki/Content/Surgeries}} | |||
[[Category:Guides]] | |||
[[Category: | |||
Latest revision as of 15:08, 8 January 2026
All surgery requires a set of medical tools, typically found in the Operating Theatre, along with an operating table.
Surgical Tools
Information about most tools used in surgery can be found here.
Surgery Speed and Failure
While every operation has an intended tool, you are not limited to it alone. Every operation has a list of alternative tools you can use instead. Beside each tool is a multiplier which indicates how much of a penalty to speed you are given for using the supplied tool.
These multipliers stack multiplicatively with those from operating site or chemicals (see Beginning of any Operation).
Note, speed penalty is capped to 2x the base time the step would have taken. A step that takes 10 seconds would cap at 20 seconds, for example.
However, every second after that cap will instead add 1 percentage point into the odds of a failure. Failing may cause extra damage or other effects.
So for example:
- Say a surgery step takes 10 seconds by default, but you use a pen (2.5x) instead of a hemostat and do it on the floor (2x) instead of a surgery table.
- Now the surgery is slowed to 50 seconds, but it's capped to 20 seconds.
- Those 30 extra seconds that were removed is now your chance to fail the operation.
- Result: The step takes 20 seconds and has a 30% chance to fail.
The Operation Process
Step 1: Undress the part of the patient that needs surgery. You can do this by dragging them onto yourself, and then clicking the clothes you want to remove from them in the pop-up. Alternatively, some clothes like jumpsuits can be adjusted out of the way, to save yourself some time.
- Important: The uniform the patient is wearing usually covers both legs, arms, groin and torso. Helmets, eyewear and masks always obscure the eyes, make sure to remove them if working on the eyes.
Step 2: Operating Table Place the patient onto the operating table. Do this doing a
on the patient. Then left click the operating table to place the patient on it. You can also
shove a person onto the table and tell them to rest, though they might not appreciate this.
- If there is no operating table, you can use: Stasis bed (1.15x), any table (1.25x), any bed (1.5x), ask them to lie on the floor (2x). The speed of completing every step will be reduced.
Step 2.1
(Optional) Splash on, spray or apply a patch with a reagent like Miner's Salve (0.9x), Sterilizine 0.8x), alcoholic drinks (up to ~0.5x*), or Honey (0.6x) for faster surgery speed.
- The stronger the alcohol, the more effective! The formula is: (booze power / 650). For example: Ethanol gives ~0.9x surgery speed, Manly Dorf ~0.85x, Bacchus' Blessing ~0.5x.
Step 2.2:
(Optional) Use a tank of anesthetic and a breath mask to make your patient sleep. This way patient won't experience agonizing pain, decreasing its mood.
Step 3:
Place drapes or bedsheet over the part of body you are operating.
- If you done step 1 wrong, it will tell you that you must remove clothing first. If you continue without fixing, you will stab your patient instead of doing surgery.
Step 4: Turn off
. Pro tip:
will make you fail every surgery step on purpose.
Step 5:
Aim at the appropriate body part (important!).
Step 6:
Begin surgery (see the steps below!).
To get to the operation you want to complete, it will require you get the patient to the necessary state*. For example, an overwhelming majority of surgeries will require the patient's skin be opened first. To open the skin you'll need to complete "Retract skin" first, and to be able to complete "Retract skin", you will need to "Make skin incision". More complicated surgeries require more complicated states, such as sawing bones.
While a patient's undergoing surgery, they will slowly lose blood. Try not to dawdle!
- Note: Some patients you receive will be in a state already ready for suregry! Species like Plasmamen have no skin, so you have nothing to make an incision in. You can simply skip that step!
Step 7: Complete your surgery
After getting to the state required, you can do whatever operation you intended. Congratulations, you just did surgery! That wasn't so bad, right?
Step 7.5: Repeat!
Feel free to do any other operation while the patient is cut open. States don't automatically get cleared after you're done! You can save yourself a lot of time this way.
Step 8: Close the patient
After all is said and done, don't forget to cauterize or suture the operated bodypart! The patient will continue to bleed if you don't.
And you're done! Send the patient out with a lollipop and a smile.
Operations
What follows is a full list of every operation that you can undergo.
Green operations are mechanical surgeries and will only work on cybernetic patients.
Purple operations are locked - typically behind technology from science, but sometimes behind rare or traitorous surgical disks. They cannot be undergone without first being loaded into an operating computer.
| File:Surgery organrepaircoronary bypassmechanic.png | Engine Diagnostic (Heart Surgery) Graft a bypass onto a patient's damaged heart to restore proper blood flow. This procedure can only be performed once per organ. |
All of these are required:
- Operate on heart (target chest)
- The skin must be open
- The organs must be cut
- The bone must be sawed
- The patient must be lying down
- The organ must be moderately damaged
However:
- The operation site must not be obstructed by clothing
- The organ must not be organic
- The organ must not have been surgically repaired prior
| Tool | Speed Multiplier | |
|---|---|---|
| File:Surgery tool crowbar.png | Crowbar | 1.05x |
| File:Surgery tool scalpel.png | Scalpel | 1.05x |
| File:Surgery tool energy sword.png | Energy sword | 1.5x |
| File:Surgery tool knife.png | Knife | 2.25x |
| File:Surgery tool shard.png | Shard | 2.85x |
| File:Surgery limbadd dental implant.png | Add dental implant Implant a pill into a patient's teeth. |
All of these are required:
- Operate on mouth (target mouth)
- The skin must be open
- The bone must be drilled
- The patient must be lying down
- The mouth must have teeth
However:
- The blood vessels must not be unclamped
- The operation site must not be obstructed by clothing
| Tool | Speed Multiplier | |
|---|---|---|
| File:Surgery tool pill.png | Pill | 1x |
| File:Surgery limbamputate.png | Disarticulation (Amputation) Sever a limb from a patient's body. |
All of these are required:
- The skin must be open
- The bone must be sawed
- The patient must be lying down
However:
- The blood vessels must not be unclamped
- The operation site must not be obstructed by clothing
- The limb must not be cybernetic
| Tool | Speed Multiplier | |
|---|---|---|
| File:Surgery tool amputation shears.png | Amputation shears | 0.33x |
| File:Surgery tool saw.png | Saw | 1x |
| File:Surgery tool scalpel.png | Scalpel | 1x |
| File:Surgery tool arm blade.png | Arm blade | 1.25x |
| File:Surgery tool serrated bone shovel.png | Serrated bone shovel | 1.33x |
| File:Surgery tool fire axe.png | Fire axe | 2x |
| File:Surgery tool hatchet.png | Hatchet | 2.5x |
| File:Surgery tool butcher's cleaver.png | Butcher's cleaver | 4x |
| File:Surgery limbreplace limb.png | Augmentation Replace a patient's limb with a robotic or prosthetic one. |
All of these are required:
- The skin must be open
- The patient must be lying down
However:
- The operation site must not be obstructed by clothing
| Tool | Speed Multiplier | |
|---|---|---|
| File:Surgery tool limb.png | Limb | 1x |
| File:Surgery limbautopsy.png | Androtomy (Dissection and Autopsy) Perform a detailed analysis of a deceased patient's body. |
All of these are required:
- Operate on chest (target chest)
- The skin must be open
- The patient must be lying down
- The patient must be deceased
- The patient must not have been autopsied prior
However:
- The limb must not be cybernetic
| Tool | Speed Multiplier | |
|---|---|---|
| File:Surgery tool autopsy scanner.png | Autopsy scanner | 1x |
| File:Surgery limbfilter blood.png | Hemodialysis (Blood Filtration) Remove unwanted chemicals from a patient's bloodstream. |
All of these are required:
- Operate on chest (target chest)
- The skin must be open
- The patient must be lying down
- The patient must not be husked
However:
- The blood vessels must not be unclamped
- The operation site must not be obstructed by clothing
- The limb must not be cybernetic
| Tool | Speed Multiplier | |
|---|---|---|
| File:Surgery tool blood filter.png | Blood filter | 1x |
| File:Surgery organrepairbrain.png | Neurosurgery (Brain Surgery) Repair a patient's damaged brain tissue to restore cognitive function. |
All of these are required:
- Operate on brain (target head)
- The skin must be open
- The bone must be sawed
- The patient must be lying down
However:
- The blood vessels must not be unclamped
- The operation site must not be obstructed by clothing
- The organ must not be cybernetic
| Tool | Speed Multiplier | |
|---|---|---|
| File:Surgery tool hemostat.png | Hemostat | 1.05x |
| File:Surgery tool screwdriver.png | Screwdriver | 2.85x |
| File:Surgery tool pen.png | Pen | 6.67x |
| File:Surgery limbcavity implant.png | Cavity implant Implant an item into a patient's body cavity. |
All of these are required:
- Operate on chest (target chest)
- The skin must be open
- The organs must be cut
- The chest cavity must be opened wide
- The patient must be lying down
However:
- The operation site must not be obstructed by clothing
| Tool | Speed Multiplier | |
|---|---|---|
| File:Surgery tool any item.png | Any item | 1x |
| File:Surgery limbclamp bleeders.png | Clamp bleeders Clamp bleeding blood vessels in the patient's body to prevent blood loss. Causes "vessels clamped" surgical state. |
All of these are required:
- The skin must be open
- The blood vessels must be unclamped
- The patient must be lying down
However:
- The operation site must not be obstructed by clothing
- The limb must not be cybernetic
| Tool | Speed Multiplier | |
|---|---|---|
| File:Surgery tool hemostat.png | Hemostat | 1x |
| File:Surgery tool cutters.png | Cutters | 1.67x |
| File:Surgery tool package wrapper.png | Package wrapper | 2.85x |
| File:Surgery tool cable coil.png | Cable coil | 6.67x |
| File:Surgery limbdebride.png | Debridement Remove infected or necrotic flesh from a patient's wound to promote healing. |
All of these are required:
- The limb must have a second degree or worse burn
- The patient must be lying down
However:
- The operation site must not be obstructed by clothing
| Tool | Speed Multiplier | |
|---|---|---|
| File:Surgery tool hemostat.png | Hemostat | 1x |
| File:Surgery tool scalpel.png | Scalpel | 1.25x |
| File:Surgery tool saw.png | Saw | 1.66x |
| File:Surgery tool cutters.png | Cutters | 2.5x |
| File:Surgery limbamputatepegleg.png | Detach Wooden Limb (Amputation) Sever a limb from a patient's body. |
All of these are required:
- The patient must be lying down
- The limb must be wooden
However:
- The blood vessels must not be unclamped
- The operation site must not be obstructed by clothing
| Tool | Speed Multiplier | |
|---|---|---|
| File:Surgery tool saw.png | Saw | 1x |
| File:Surgery tool serrated bone shovel.png | Serrated bone shovel | 1x |
| File:Surgery tool fire axe.png | Fire axe | 1.15x |
| File:Surgery tool hatchet.png | Hatchet | 1.33x |
| File:Surgery tool scalpel.png | Scalpel | 4x |
| File:Surgery limbamputatemechanic.png | Dissassembly (Amputation) Sever a limb from a patient's body. |
All of these are required:
- The skin must be open
- The patient must be lying down
Any one of these is required:
- If operating on the head, the bone MUST be sawed
- Otherwise, the state of the bone doesn't matter
However:
- The blood vessels must not be unclamped
- The operation site must not be obstructed by clothing
- The limb must not be organic
| Tool | Speed Multiplier | |
|---|---|---|
| File:Surgery tool wrench.png | Wrench | 1x |
| File:Surgery tool crowbar.png | Crowbar | 1x |
| File:Surgery tool scalpel.png | Scalpel | 2x |
| File:Surgery tool saw.png | Saw | 2x |
| File:Surgery limbprepare cranium repair.png | Discard skull debris Clear away bone fragments and debris from a patient's cranial fissure in preparation for repair. |
All of these are required:
- The cranium must be fractured
- The patient must be lying down
However:
- The operation site must not be obstructed by clothing
| Tool | Speed Multiplier | |
|---|---|---|
| File:Surgery tool hemostat.png | Hemostat | 1x |
| File:Surgery tool cutters.png | Cutters | 2.5x |
| File:Surgery tool screwdriver.png | Screwdriver | 2.5x |
| File:Surgery limbdrill bones.png | Drill limb bone Drill through a patient's bones. Causes "bone drilled" surgical state. |
All of these are required:
- The skin must be open
- The patient must be lying down
However:
- The bone must be intact
- The operation site must not be obstructed by clothing
- The limb must not be cybernetic
| Tool | Speed Multiplier | |
|---|---|---|
| File:Surgery tool drill.png | Drill | 1x |
| File:Surgery tool hand drill.png | Hand drill | 1.25x |
| File:Surgery tool mining drill.png | Mining drill | 1.67x |
| File:Surgery tool screwdriver.png | Screwdriver | 4x |
| File:Surgery tool spoon.png | Spoon | 5x |
| File:Surgery tool any sharp pointed item with decent force.png | Any sharp pointed item with decent force | 6.67x |
| File:Surgery organrepairears.png | Ototomy (Ear surgery) Repair a patient's damaged ears to restore hearing. |
All of these are required:
- Operate on ears (target head)
- The skin must be open
- The patient must be lying down
However:
- The blood vessels must not be unclamped
- The operation site must not be obstructed by clothing
- The organ must not be cybernetic
- If the limb has bones, they must be intact
| Tool | Speed Multiplier | |
|---|---|---|
| File:Surgery tool hemostat.png | Hemostat | 1.05x |
| File:Surgery tool screwdriver.png | Screwdriver | 2.25x |
| File:Surgery tool pen.png | Pen | 4x |
| File:Surgery limblipoplastymechanic.png | Nutrient Reserve Expulsion (Excise Fat) Remove excess fat from a patient's body. |
All of these are required:
- Operate on chest (target chest)
- The skin must be open
- The patient must be lying down
- The patient must have excess fat to remove
However:
- The blood vessels must not be unclamped
- The operation site must not be obstructed by clothing
- The limb must not be organic
| Tool | Speed Multiplier | |
|---|---|---|
| File:Surgery tool wrench.png | Wrench | 1.05x |
| File:Surgery tool crowbar.png | Crowbar | 1.05x |
| File:Surgery tool serrated bone shovel.png | Serrated bone shovel | 1.33x |
| File:Surgery tool energy sword.png | Energy sword | 1.33x |
| File:Surgery tool saw.png | Saw | 1.67x |
| File:Surgery tool hatchet.png | Hatchet | 3.33x |
| File:Surgery tool knife.png | Knife | 3.33x |
| File:Surgery tool scalpel.png | Scalpel | 4x |
| File:Surgery tool any sharp edged item.png | Any sharp edged item | 5x |
| File:Surgery organrepairlobectomy.png | Lobectomy (Lung Surgery) Perform repairs to a patient's damaged lung by excising the most damaged lobe. This procedure can only be performed once per organ. |
All of these are required:
- Operate on lungs (target chest)
- The skin must be open
- The organs must be cut
- The bone must be sawed
- The patient must be lying down
- The organ must be moderately damaged
However:
- The operation site must not be obstructed by clothing
- The organ must not be cybernetic
- The organ must not have been surgically repaired prior
| Tool | Speed Multiplier | |
|---|---|---|
| File:Surgery tool scalpel.png | Scalpel | 1.05x |
| File:Surgery tool energy sword.png | Energy sword | 1.5x |
| File:Surgery tool knife.png | Knife | 2.25x |
| File:Surgery tool shard.png | Shard | 2.85x |
| File:Surgery limblipoplasty.png | Lipoplasty (Excise Fat) Remove excess fat from a patient's body. |
All of these are required:
- Operate on chest (target chest)
- The skin must be open
- The patient must be lying down
- The patient must have excess fat to remove
However:
- The blood vessels must not be unclamped
- The operation site must not be obstructed by clothing
- The limb must not be cybernetic
| Tool | Speed Multiplier | |
|---|---|---|
| File:Surgery tool saw.png | Saw | 1x |
| File:Surgery tool scalpel.png | Scalpel | 1.25x |
| File:Surgery tool serrated bone shovel.png | Serrated bone shovel | 1.33x |
| File:Surgery tool energy sword.png | Energy sword | 1.33x |
| File:Surgery tool hatchet.png | Hatchet | 3.33x |
| File:Surgery tool knife.png | Knife | 3.33x |
| File:Surgery tool any sharp edged item.png | Any sharp edged item | 5x |
| File:Surgery basiccore removal.png | Corectomy (Extract Core) Remove the core from a slime. |
All of these are required:
- Operate on a deceased slime
- Operate on chest (target chest)
- The skin must be cut or opened
| Tool | Speed Multiplier | |
|---|---|---|
| File:Surgery tool hemostat.png | Hemostat | 1x |
| File:Surgery tool crowbar.png | Crowbar | 1x |
| File:Surgery organrepaireyes.png | Vitrectomy (Eye Surgery) Repair a patient's damaged eyes to restore vision. |
All of these are required:
- Operate on eyes (target eyes)
- The skin must be open
- The patient must be lying down
However:
- The blood vessels must not be unclamped
- The operation site must not be obstructed by clothing
- The organ must not be cybernetic
- If the limb has bones, they must be intact
| Tool | Speed Multiplier | |
|---|---|---|
| File:Surgery tool hemostat.png | Hemostat | 1.05x |
| File:Surgery tool screwdriver.png | Screwdriver | 2.25x |
| File:Surgery tool pen.png | Pen | 4x |
| File:Surgery limborgan manipulationexternal.png | Feature manipulation Manipulate features of the patient, such as a moth's wings or a lizard's tail. |
All of these are required:
- The skin must be open
- The bone must be sawed
- The patient must be lying down
However:
- The blood vessels must not be unclamped
- The operation site must not be obstructed by clothing
- The limb must not be cybernetic
| Tool | Speed Multiplier | |
|---|---|---|
| File:Surgery tool hemostat.png | Hemostat | 1x |
| File:Surgery tool crowbar.png | Crowbar | 1.8x |
| File:Surgery tool fork.png | Fork | 2.85x |
| File:Surgery tool organ.png | Organ | 1x |
| File:Surgery limbfix bones.png | Fix limb bone Repair a patient's cut or broken bones. Clears "bone sawed" and "bone drilled" surgical states. |
All of these are required:
- The skin must be open
- The patient must be lying down
- The limb must have bones
- The bone must be sawed or drilled
However:
- The operation site must not be obstructed by clothing
- The limb must not be cybernetic
| Tool | Speed Multiplier | |
|---|---|---|
| File:Surgery tool bone gel.png | Bone gel | 1x |
| File:Surgery tool surgical tape.png | Surgical tape | 1x |
| File:Surgery tool super sticky tape.png | Super sticky tape | 2x |
| File:Surgery tool sticky tape.png | Sticky tape | 3.33x |
| File:Surgery organasthmatic bypass.png | Bronchial Dilatation (Asthmatic Bypass) Forcibly expand a patient's windpipe, relieving asthma symptoms. |
All of these are required:
- The patient must be asthmatic
- Operate on lungs (target chest)
- The skin must be open
- The organs must be cut
- The patient must be lying down
However:
- The operation site must not be obstructed by clothing
- The organ must not be cybernetic
| Tool | Speed Multiplier | |
|---|---|---|
| File:Surgery tool retractor.png | Retractor | 1.25x |
| File:Surgery tool cutters.png | Cutters | 2.25x |
| File:Surgery basicrevivalmechanic.png | Brain Defibrillation (Revival) Use a defibrillator to shock a patient's brain back to life. |
All of these are required:
- Operate on head (target head)
- The skin must be open
- The bone must be sawed
- The patient must be lying down
- The patient must be deceased
- The patient must be in a revivable state
However:
- The operation site must not be obstructed by clothing
- The patient must not be organic
| Tool | Speed Multiplier | |
|---|---|---|
| File:Surgery tool defibrillator paddles.png | Defibrillator paddles | 1x |
| File:Surgery tool shock touch.png | Shock touch | 1x |
| File:Surgery tool stun baton.png | Stun baton | 1.33x |
| File:Surgery tool energy gun.png | Energy gun | 1.67x |
| File:Surgery organrepaircoronary bypass.png | Coronary Artery Bypass Graft (Heart Surgery) Graft a bypass onto a patient's damaged heart to restore proper blood flow. This procedure can only be performed once per organ. |
All of these are required:
- Operate on heart (target chest)
- The skin must be open
- The organs must be cut
- The bone must be sawed
- The patient must be lying down
- The organ must be moderately damaged
However:
- The operation site must not be obstructed by clothing
- The organ must not be cybernetic
- The organ must not have been surgically repaired prior
| Tool | Speed Multiplier | |
|---|---|---|
| File:Surgery tool hemostat.png | Hemostat | 1.05x |
| File:Surgery tool cutters.png | Cutters | 2.85x |
| File:Surgery tool package wrapper.png | Package wrapper | 6.67x |
| File:Surgery tool cable coil.png | Cable coil | 2x |
| File:Surgery basicimplant removal.png | Implant removal Attempt to find and remove an implant from a patient. Any implant found will be destroyed unless an implant case is held or nearby. |
All of these are required:
- Operate on chest (target chest)
- The skin must be open
- The patient must be lying down
You may optionally:
- Have an implant case below or inhand to store removed implants
However:
- The blood vessels must not be unclamped
- The operation site must not be obstructed by clothing
- The patient must not be robotic
| Tool | Speed Multiplier | |
|---|---|---|
| File:Surgery tool hemostat.png | Hemostat | 1x |
| File:Surgery tool crowbar.png | Crowbar | 1.5x |
| File:Surgery tool fork.png | Fork | 2.85x |
| File:Surgery limbincise organs.png | Incise organs Make an incision in patient's internal organ tissue to allow for manipulation or repair. Causes "organs cut" surgical state. |
All of these are required:
- The skin must be open
- The patient must be lying down
However:
- The organs must not be cut
- The operation site must not be obstructed by clothing
- The limb must not be cybernetic
| Tool | Speed Multiplier | |
|---|---|---|
| File:Surgery tool scalpel.png | Scalpel | 1x |
| File:Surgery tool energy sword.png | Energy sword | 1.33x |
| File:Surgery tool knife.png | Knife | 1.5x |
| File:Surgery tool shard.png | Shard | 2.25x |
| File:Surgery tool pen.png | Pen | 5x |
| File:Surgery tool any sharp edged item.png | Any sharp edged item | 3.33x |
| File:Surgery limborgan manipulationinternal.png | Internal organ manipulation Manipulate a patient's internal organs. |
All of these are required:
- The skin must be open
- The organs must be cut
- The patient must be lying down
Any one of these is required:
- If operating on the brain or any chest organs, the bone MUST be sawed
- Otherwise, the state of the bone doesn't matter
However:
- The operation site must not be obstructed by clothing
- The limb must not be cybernetic
| Tool | Speed Multiplier | |
|---|---|---|
| File:Surgery tool hemostat.png | Hemostat | 1x |
| File:Surgery tool crowbar.png | Crowbar | 1.8x |
| File:Surgery tool fork.png | Fork | 2.85x |
| File:Surgery tool organ.png | Organ | 1x |
| File:Surgery basicincise skin.png | Make incision Make an incision in the patient's skin to access internals. Causes "cut skin" surgical state. |
All of these are required:
- Operate on patient
- The patient must be lying down
However:
- The skin must be intact
- The operation site must not be obstructed by clothing
- The patient must not be robotic
- The patient must not have complex anatomy
| Tool | Speed Multiplier | |
|---|---|---|
| File:Surgery tool scalpel.png | Scalpel | 1x |
| File:Surgery tool energy sword.png | Energy sword | 1.33x |
| File:Surgery tool knife.png | Knife | 1.5x |
| File:Surgery tool shard.png | Shard | 2.25x |
| File:Surgery tool screwdriver.png | Screwdriver | 5x |
| File:Surgery tool pen.png | Pen | 5x |
| File:Surgery tool any sharp edged item.png | Any sharp edged item | 3.33x |
| File:Surgery limbincise skin.png | Make skin incision Make an incision in the patient's skin to access internal organs. Causes "cut skin" surgical state. |
All of these are required:
- The patient must be lying down
However:
- The skin must be intact
- The operation site must not be obstructed by clothing
- The limb must not be cybernetic
| Tool | Speed Multiplier | |
|---|---|---|
| File:Surgery tool scalpel.png | Scalpel | 1x |
| File:Surgery tool energy sword.png | Energy sword | 1.33x |
| File:Surgery tool knife.png | Knife | 1.5x |
| File:Surgery tool shard.png | Shard | 2.25x |
| File:Surgery tool screwdriver.png | Screwdriver | 5x |
| File:Surgery tool pen.png | Pen | 5x |
| File:Surgery tool any sharp edged item.png | Any sharp edged item | 3.33x |
| File:Surgery limbincise skinthick.png | Make thick skin incision Make an incision in the patient's skin to access internal organs. Causes "cut skin" surgical state. |
All of these are required:
- The patient must be lying down
However:
- The skin must be intact
- The operation site must not be obstructed by clothing
- The limb must not be cybernetic
| Tool | Speed Multiplier | |
|---|---|---|
| File:Surgery tool saw.png | Saw | 1x |
| File:Surgery tool energy sword.png | Energy sword | 1.25x |
| File:Surgery tool fire axe.png | Fire axe | 1.5x |
| File:Surgery tool butcher's cleaver.png | Butcher's cleaver | 2.5x |
| File:Surgery tool any sharp edged item with decent force.png | Any sharp edged item with decent force | 5x |
| File:Surgery basicclose skin.png | Mend incision Mend the incision in the patient's skin, closing it up. Clears most surgical states. |
All of these are required:
- Operate on patient
- The patient must be lying down
Any one of these is required:
- The bone must be sawed or drilled
- The skin must be cut or opened
- The blood vessels must be clamped or unclamped
- The organs must be cut
- The chest cavity must be opened wide
However:
- The operation site must not be obstructed by clothing
- The patient must not be robotic
- The patient must not have complex anatomy
| Tool | Speed Multiplier | |
|---|---|---|
| File:Surgery tool cautery.png | Cautery | 1x |
| File:Surgery tool suture.png | Suture | 1x |
| File:Surgery tool type 5 laser gun.png | Type 5 laser gun | 1.15x |
| File:Surgery tool welder.png | Welder | 1.5x |
| File:Surgery tool any heat source.png | Any heat source | 3.33x |
| File:Surgery limbclose skin.png | Mend skin incision Mend the incision in the patient's skin, closing it up. Clears most surgical states. |
All of these are required:
- The patient must be lying down
- The limb must have skin
- The skin must be cut or opened
However:
- The operation site must not be obstructed by clothing
- The limb must not be cybernetic
| Tool | Speed Multiplier | |
|---|---|---|
| File:Surgery tool cautery.png | Cautery | 1x |
| File:Surgery tool suture.png | Suture | 1x |
| File:Surgery tool type 5 laser gun.png | Type 5 laser gun | 1.15x |
| File:Surgery tool welder.png | Welder | 1.5x |
| File:Surgery tool any heat source.png | Any heat source | 3.33x |
| File:Surgery limbmechanical open.png | Open hatch Open the hatch of a mechanical patient to access its internals. Causes "skin open" and "vessels clamped" surgical states. |
All of these are required:
- The skin must be cut
- The patient must be lying down
You may optionally:
- A surgeon may perform this on themselves
However:
- The operation site must not be obstructed by clothing
- The limb must not be organic
| Tool | Speed Multiplier | |
|---|---|---|
| File:Surgery tool hands.png | Hands | 1x |
| File:Surgery tool crowbar.png | Crowbar | 1x |
| File:Surgery organrepairlobectomymechanic.png | Air Filtration Diagnostic (Lung Surgery) Perform repairs to a patient's damaged lung by excising the most damaged lobe. This procedure can only be performed once per organ. |
All of these are required:
- Operate on lungs (target chest)
- The skin must be open
- The organs must be cut
- The bone must be sawed
- The patient must be lying down
- The organ must be moderately damaged
However:
- The operation site must not be obstructed by clothing
- The organ must not be organic
- The organ must not have been surgically repaired prior
| Tool | Speed Multiplier | |
|---|---|---|
| File:Surgery tool wrench.png | Wrench | 1.05x |
| File:Surgery tool scalpel.png | Scalpel | 1.05x |
| File:Surgery tool energy sword.png | Energy sword | 1.5x |
| File:Surgery tool knife.png | Knife | 2.25x |
| File:Surgery tool shard.png | Shard | 2.85x |
| File:Surgery organrepairhepatectomymechanic.png | Impurity Management System Diagnostic (Liver Surgery) Perform repairs to a patient's damaged liver by removing the most damaged section. This procedure can only be performed once per organ. |
All of these are required:
- Operate on liver (target chest)
- The skin must be open
- The organs must be cut
- The bone must be sawed
- The patient must be lying down
- The organ must be moderately damaged
However:
- The operation site must not be obstructed by clothing
- The organ must not be organic
- The organ must not have been surgically repaired prior
| Tool | Speed Multiplier | |
|---|---|---|
| File:Surgery tool wrench.png | Wrench | 1.05x |
| File:Surgery tool scalpel.png | Scalpel | 1.05x |
| File:Surgery tool energy sword.png | Energy sword | 1.5x |
| File:Surgery tool knife.png | Knife | 2.25x |
| File:Surgery tool shard.png | Shard | 2.85x |
| File:Surgery organrepairgastrectomymechanic.png | Nutrient Processing System Diagnostic (Stomach Surgery) Perform repairs to a patient's stomach by removing a damaged section. This procedure can only be performed once per organ. |
All of these are required:
- Operate on stomach (target chest)
- The skin must be open
- The organs must be cut
- The bone must be sawed
- The patient must be lying down
- The organ must be moderately damaged
However:
- The operation site must not be obstructed by clothing
- The organ must not be organic
- The organ must not have been surgically repaired prior
| Tool | Speed Multiplier | |
|---|---|---|
| File:Surgery tool wrench.png | Wrench | 1.05x |
| File:Surgery tool scalpel.png | Scalpel | 1.05x |
| File:Surgery tool energy sword.png | Energy sword | 1.5x |
| File:Surgery tool knife.png | Knife | 2.25x |
| File:Surgery tool shard.png | Shard | 2.85x |
| File:Surgery tool any sharp edged item.png | Any sharp edged item | 4x |
| File:Surgery organrepairbrainmechanic.png | Wetware OS Diagnostics (Brain Surgery) Repair a patient's damaged brain tissue to restore cognitive function. |
All of these are required:
- Operate on brain (target head)
- The skin must be open
- The bone must be sawed
- The patient must be lying down
However:
- The blood vessels must not be unclamped
- The operation site must not be obstructed by clothing
- The organ must not be organic
| Tool | Speed Multiplier | |
|---|---|---|
| File:Surgery tool multitool.png | Multitool | 1.15x |
| File:Surgery tool hemostat.png | Hemostat | 1.05x |
| File:Surgery tool screwdriver.png | Screwdriver | 2.85x |
| File:Surgery tool pen.png | Pen | 6.67x |
| File:Surgery limbplastic surgery.png | Plastic surgery Reshape or reconstruct a patient's face for cosmetic or functional purposes. |
All of these are required:
- Operate on head (target head)
- The skin must be open
- The patient must be lying down
However:
- The operation site must not be obstructed by clothing
| Tool | Speed Multiplier | |
|---|---|---|
| File:Surgery tool scalpel.png | Scalpel | 1x |
| File:Surgery tool knife.png | Knife | 2x |
| File:Surgery tool cutters.png | Cutters | 2.85x |
| File:Surgery tool pen.png | Pen | 5x |
| File:Surgery limbprepare electronics.png | Prepare electronics Prepare the internal electronics of a mechanical patient for surgery. Causes "organs cut" surgical state. |
All of these are required:
- The skin must be open
- The patient must be lying down
You may optionally:
- A surgeon may perform this on themselves
However:
- The organs must not be cut
- The operation site must not be obstructed by clothing
- The limb must not be organic
| Tool | Speed Multiplier | |
|---|---|---|
| File:Surgery tool multitool.png | Multitool | 1x |
| File:Surgery tool hemostat.png | Hemostat | 1.33x |
| File:Surgery limborgan manipulationexternalmechanic.png | Prosthetic feature manipulation Manipulate features of the patient, such as a moth's wings or a lizard's tail. |
All of these are required:
- The skin must be open
- The bone must be sawed
- The patient must be lying down
You may optionally:
- A surgeon may perform this on themselves
However:
- The blood vessels must not be unclamped
- The operation site must not be obstructed by clothing
- The limb must not be organic
| Tool | Speed Multiplier | |
|---|---|---|
| File:Surgery tool crowbar.png | Crowbar | 1x |
| File:Surgery tool hemostat.png | Hemostat | 1x |
| File:Surgery tool fork.png | Fork | 2.85x |
| File:Surgery tool organ.png | Organ | 1x |
| File:Surgery limborgan manipulationinternalmechanic.png | Prosthetic organ manipulation Manipulate a patient's internal organs. |
All of these are required:
- The skin must be open
- The organs must be cut
- The patient must be lying down
Any one of these is required:
- If operating on the brain or any chest organs, the bone MUST be sawed
- Otherwise, the state of the bone doesn't matter
You may optionally:
- A surgeon may perform this on themselves
However:
- The operation site must not be obstructed by clothing
- The limb must not be organic
| Tool | Speed Multiplier | |
|---|---|---|
| File:Surgery tool crowbar.png | Crowbar | 1x |
| File:Surgery tool hemostat.png | Hemostat | 1x |
| File:Surgery tool fork.png | Fork | 2.85x |
| File:Surgery tool organ.png | Organ | 1x |
| File:Surgery prosthetic replacement.png | Prosthetic replacement Replace a missing limb with a prosthetic (or arbitrary) item. |
All of these are required:
- Operate on chest (target chest)
- The skin must be open
- When the chest is prepared, target the zone of the limb you are attaching
- Arms may receive any suitable item in lieu of a replacement limb
However:
- The blood vessels must not be unclamped
| Tool | Speed Multiplier | |
|---|---|---|
| File:Surgery tool limb.png | Limb | 1x |
| File:Surgery tool any suitable arm replacement.png | Any suitable arm replacement | 1x |
| File:Surgery organstomach pump.png | Gastric Lavage (Stomach Pump) Manually pump a patient's stomach to induce vomiting and expel harmful chemicals. |
All of these are required:
- Operate on stomach (target chest)
- The skin must be open
- The organs must be cut
- The patient must be lying down
- The patient must not be husked
However:
- The operation site must not be obstructed by clothing
- The organ must not be cybernetic
| Tool | Speed Multiplier | |
|---|---|---|
| File:Surgery tool hands.png | Hands | 1x |
| File:Surgery limbfilter bloodmechanic.png | Hydraulics Purge (Blood Filtration) Remove unwanted chemicals from a patient's bloodstream. |
All of these are required:
- Operate on chest (target chest)
- The skin must be open
- The patient must be lying down
- The patient must not be husked
However:
- The blood vessels must not be unclamped
- The operation site must not be obstructed by clothing
- The limb must not be organic
| Tool | Speed Multiplier | |
|---|---|---|
| File:Surgery tool blood filter.png | Blood filter | 1x |
| File:Surgery organstomach pumpmechanic.png | Nutrient Processor Purge (Stomach Pump) Manually pump a patient's stomach to induce vomiting and expel harmful chemicals. |
All of these are required:
- Operate on stomach (target chest)
- The skin must be open
- The organs must be cut
- The patient must be lying down
- The patient must not be husked
However:
- The operation site must not be obstructed by clothing
- The organ must not be organic
| Tool | Speed Multiplier | |
|---|---|---|
| File:Surgery tool hands.png | Hands | 1x |
| File:Surgery limbrepair puncture.png | Realign blood vessels Realign a patient's torn blood vessels to prepare for sealing. |
All of these are required:
- The limb must have an unoperated puncture wound
- The skin must be open
- The organs must be cut
- The patient must be lying down
However:
- The operation site must not be obstructed by clothing
| Tool | Speed Multiplier | |
|---|---|---|
| File:Surgery tool hemostat.png | Hemostat | 1x |
| File:Surgery tool scalpel.png | Scalpel | 1.15x |
| File:Surgery tool cutters.png | Cutters | 2.5x |
| File:Surgery limbundo cavity implant.png | Remove cavity implant Remove an item from a body cavity. |
All of these are required:
- Operate on chest (target chest)
- The skin must be open
- The organs must be cut
- The chest cavity must be opened wide
- The patient must be lying down
However:
- The operation site must not be obstructed by clothing
| Tool | Speed Multiplier | |
|---|---|---|
| File:Surgery tool hands.png | Hands | 1x |
| File:Surgery tool hemostat.png | Hemostat | 2x |
| File:Surgery tool crowbar.png | Crowbar | 2.5x |
| File:Surgery tool fork.png | Fork | 5x |
| File:Surgery organrepairhepatectomy.png | Hepatectomy (Liver Surgery) Perform repairs to a patient's damaged liver by removing the most damaged section. This procedure can only be performed once per organ. |
All of these are required:
- Operate on liver (target chest)
- The skin must be open
- The organs must be cut
- The bone must be sawed
- The patient must be lying down
- The organ must be moderately damaged
However:
- The operation site must not be obstructed by clothing
- The organ must not be cybernetic
- The organ must not have been surgically repaired prior
| Tool | Speed Multiplier | |
|---|---|---|
| File:Surgery tool scalpel.png | Scalpel | 1.05x |
| File:Surgery tool energy sword.png | Energy sword | 1.5x |
| File:Surgery tool knife.png | Knife | 2.25x |
| File:Surgery tool shard.png | Shard | 2.85x |
| File:Surgery organrepairgastrectomy.png | Gastrectomy (Stomach Surgery) Perform repairs to a patient's stomach by removing a damaged section. This procedure can only be performed once per organ. |
All of these are required:
- Operate on stomach (target chest)
- The skin must be open
- The organs must be cut
- The bone must be sawed
- The patient must be lying down
- The organ must be moderately damaged
However:
- The operation site must not be obstructed by clothing
- The organ must not be cybernetic
- The organ must not have been surgically repaired prior
| Tool | Speed Multiplier | |
|---|---|---|
| File:Surgery tool scalpel.png | Scalpel | 1.05x |
| File:Surgery tool energy sword.png | Energy sword | 1.5x |
| File:Surgery tool knife.png | Knife | 2.25x |
| File:Surgery tool shard.png | Shard | 2.85x |
| File:Surgery tool any sharp edged item.png | Any sharp edged item | 4x |
| File:Surgery limbremove dental implant.png | Remove dental implant Remove a dental implant from a patient's teeth. |
All of these are required:
- The skin must be open
- The bone must be drilled
- The patient must be lying down
However:
- The blood vessels must not be unclamped
- The operation site must not be obstructed by clothing
| Tool | Speed Multiplier | |
|---|---|---|
| File:Surgery tool hemostat.png | Hemostat | 1x |
| File:Surgery tool hands.png | Hands | 1x |
| File:Surgery limbrepair compound.png | Repair compound fracture Mend a compound fracture in a patient's bone. |
All of these are required:
- The limb's compound fracture has been reset
- The patient must be lying down
- The skin must be cut or opened
However:
- The operation site must not be obstructed by clothing
| Tool | Speed Multiplier | |
|---|---|---|
| File:Surgery tool bone gel.png | Bone gel | 1x |
| File:Surgery tool surgical tape.png | Surgical tape | 1x |
| File:Surgery tool super sticky tape.png | Super sticky tape | 2x |
| File:Surgery tool sticky tape.png | Sticky tape | 3.33x |
| File:Surgery limbrepair cranium.png | Repair cranium Mend a cranial fissure in a patient's skull. |
All of these are required:
- The debris has been cleared from the cranial fissure
- The patient must be lying down
However:
- The operation site must not be obstructed by clothing
| Tool | Speed Multiplier | |
|---|---|---|
| File:Surgery tool bone gel.png | Bone gel | 1x |
| File:Surgery tool surgical tape.png | Surgical tape | 1x |
| File:Surgery tool super sticky tape.png | Super sticky tape | 2x |
| File:Surgery tool sticky tape.png | Sticky tape | 3.33x |
| File:Surgery limbrepair hairline.png | Repair hairline fracture Mend a hairline fracture in a patient's bone. |
All of these are required:
- The limb must have a hairline fracture
- The patient must be lying down
- The skin must be cut or opened
However:
- The operation site must not be obstructed by clothing
| Tool | Speed Multiplier | |
|---|---|---|
| File:Surgery tool bonesetter.png | Bonesetter | 1x |
| File:Surgery tool bone gel.png | Bone gel | 1x |
| File:Surgery tool surgical tape.png | Surgical tape | 1x |
| File:Surgery tool super sticky tape.png | Super sticky tape | 2x |
| File:Surgery tool sticky tape.png | Sticky tape | 3.33x |
| File:Surgery limbreset compound.png | Reset compound fracture Reset a compound fracture in a patient's bone, preparing it for proper healing. |
All of these are required:
- The limb must have a compound fracture
- The skin must be open
- The patient must be lying down
However:
- The blood vessels must not be unclamped
- The operation site must not be obstructed by clothing
| Tool | Speed Multiplier | |
|---|---|---|
| File:Surgery tool bonesetter.png | Bonesetter | 1x |
| File:Surgery tool surgical tape.png | Surgical tape | 1.66x |
| File:Surgery tool super sticky tape.png | Super sticky tape | 2.5x |
| File:Surgery tool sticky tape.png | Sticky tape | 5x |
| File:Surgery limbrepair dislocation.png | Reset dislocation Reset a dislocated bone in a patient's limb. Similar to the field procedure, but quicker and safer due to being performed in a controlled environment. |
All of these are required:
- The limb must be dislocated
However:
- The operation site must not be obstructed by clothing
| Tool | Speed Multiplier | |
|---|---|---|
| File:Surgery tool bonesetter.png | Bonesetter | 1x |
| File:Surgery tool crowbar.png | Crowbar | 2x |
| File:Surgery tool hands.png | Hands | 5x |
| File:Surgery limbretract skin.png | Retract skin Retract the patient's skin to access their internal organs. Causes "skin open" surgical state. |
All of these are required:
- The skin must be cut
- The patient must be lying down
However:
- The operation site must not be obstructed by clothing
- The limb must not be cybernetic
| Tool | Speed Multiplier | |
|---|---|---|
| File:Surgery tool retractor.png | Retractor | 1x |
| File:Surgery tool screwdriver.png | Screwdriver | 2.25x |
| File:Surgery tool cutters.png | Cutters | 2.85x |
| File:Surgery tool iron rod.png | Iron rod | 2.85x |
| File:Surgery tool fork.png | Fork | 2.85x |
| File:Surgery basicsaw bone.png | Saw bone Saw through the patient's bones to access their internal organs. Causes "bone sawed" surgical state. |
All of these are required:
- Operate on patient
- The skin must be open
- The patient must be lying down
However:
- The bone must be intact
- The operation site must not be obstructed by clothing
- The patient must not be robotic
- The patient must not have complex anatomy
| Tool | Speed Multiplier | |
|---|---|---|
| File:Surgery tool saw.png | Saw | 1x |
| File:Surgery tool serrated bone shovel.png | Serrated bone shovel | 1.33x |
| File:Surgery tool arm blade.png | Arm blade | 1.33x |
| File:Surgery tool fire axe.png | Fire axe | 2x |
| File:Surgery tool hatchet.png | Hatchet | 2.85x |
| File:Surgery tool butcher's cleaver.png | Butcher's cleaver | 2.85x |
| File:Surgery tool any sharp edged item with decent force.png | Any sharp edged item with decent force | 4x |
| File:Surgery limbsaw bones.png | Saw limb bone Saw through the patient's bones to access their internal organs. Causes "bone sawed" surgical state. |
All of these are required:
- The skin must be open
- The patient must be lying down
However:
- The bone must be intact
- The operation site must not be obstructed by clothing
- The limb must not be cybernetic
| Tool | Speed Multiplier | |
|---|---|---|
| File:Surgery tool saw.png | Saw | 1x |
| File:Surgery tool serrated bone shovel.png | Serrated bone shovel | 1.33x |
| File:Surgery tool arm blade.png | Arm blade | 1.33x |
| File:Surgery tool fire axe.png | Fire axe | 2x |
| File:Surgery tool hatchet.png | Hatchet | 2.85x |
| File:Surgery tool butcher's cleaver.png | Butcher's cleaver | 2.85x |
| File:Surgery tool any sharp edged item with decent force.png | Any sharp edged item with decent force | 4x |
| File:Surgery limbmechanical close.png | Screw shell Screw the shell of a mechanical patient back into place. Clears most surgical states. |
All of these are required:
- The patient must be lying down
- The skin must be cut or opened
You may optionally:
- A surgeon may perform this on themselves
However:
- The operation site must not be obstructed by clothing
- The limb must not be organic
| Tool | Speed Multiplier | |
|---|---|---|
| File:Surgery tool screwdriver.png | Screwdriver | 1x |
| File:Surgery tool scalpel.png | Scalpel | 1.33x |
| File:Surgery tool knife.png | Knife | 2x |
| File:Surgery tool any sharp item.png | Any sharp item | 10x |
| File:Surgery limbseal veins.png | Seal blood vessels Seal a patient's now-realigned blood vessels. |
All of these are required:
- The limb must have an operated puncture wound
- The skin must be open
- The organs must be cut
- The patient must be lying down
However:
- The operation site must not be obstructed by clothing
| Tool | Speed Multiplier | |
|---|---|---|
| File:Surgery tool cautery.png | Cautery | 1x |
| File:Surgery tool type 5 laser gun.png | Type 5 laser gun | 1.12x |
| File:Surgery tool welder.png | Welder | 1.5x |
| File:Surgery tool any heat source.png | Any heat source | 3.33x |
| File:Surgery limbsecure arbitrary prosthetic.png | Secure prosthetic Ensure that an arbitrary prosthetic is properly attached to a patient's body. |
All of these are required:
- The prosthetic must be unsecured
You may optionally:
- A surgeon may perform this on themselves
However:
- The operation site must not be obstructed by clothing
| Tool | Speed Multiplier | |
|---|---|---|
| File:Surgery tool suture.png | Suture | 1x |
| File:Surgery tool surgical tape.png | Surgical tape | 1.25x |
| File:Surgery tool sticky tape.png | Sticky tape | 2x |
| File:Surgery basicrevival.png | Brain Defibrillation (Revival) Use a defibrillator to shock a patient's brain back to life. |
All of these are required:
- Operate on head (target head)
- The skin must be open
- The bone must be sawed
- The patient must be lying down
- The patient must be deceased
- The patient must be in a revivable state
However:
- The operation site must not be obstructed by clothing
| Tool | Speed Multiplier | |
|---|---|---|
| File:Surgery tool defibrillator paddles.png | Defibrillator paddles | 1x |
| File:Surgery tool shock touch.png | Shock touch | 1x |
| File:Surgery tool stun baton.png | Stun baton | 1.33x |
| File:Surgery tool energy gun.png | Energy gun | 1.67x |
| File:Surgery limbautopsymechanic.png | System Failure Analysis (Dissection and Autopsy) Perform a detailed analysis of a robotic patient's deactivated systems. |
All of these are required:
- Operate on chest (target chest)
- The skin must be open
- The patient must be lying down
- The patient must be deceased
- The patient must not have been autopsied prior
However:
- The limb must not be organic
| Tool | Speed Multiplier | |
|---|---|---|
| File:Surgery tool autopsy scanner.png | Autopsy scanner | 1x |
| File:Surgery basictend wounds.png | Tend Wounds Perform superficial wound care on a patient's bruises and burns. |
All of these are required:
- Operate on chest (target chest)
- The patient must be lying down
- The patient must have brute or burn damage
- The skin must be cut or opened
However:
- The patient must not be robotic
| Tool | Speed Multiplier | |
|---|---|---|
| File:Surgery tool hemostat.png | Hemostat | 1x |
| File:Surgery tool screwdriver.png | Screwdriver | 1.5x |
| File:Surgery tool cutters.png | Cutters | 1.67x |
| File:Surgery tool pen.png | Pen | 1.8x |
| File:Surgery limbunclamp bleeders.png | Unclamp bleeders Unclamp blood vessels in the patient's body to allow blood flow again. Clears "vessels clamped" surgical state. |
All of these are required:
- The skin must be open
- The blood vessels must be clamped
- The patient must be lying down
- The limb must have blood vessels
However:
- The operation site must not be obstructed by clothing
- The limb must not be cybernetic
| Tool | Speed Multiplier | |
|---|---|---|
| File:Surgery tool hemostat.png | Hemostat | 1x |
| File:Surgery tool cutters.png | Cutters | 1.67x |
| File:Surgery tool package wrapper.png | Package wrapper | 2.85x |
| File:Surgery tool cable coil.png | Cable coil | 6.67x |
| File:Surgery limbmechanical incision.png | Unscrew shell Unscrew the shell of a mechanical patient to access its internals. Causes "cut skin" surgical state. |
All of these are required:
- The patient must be lying down
You may optionally:
- A surgeon may perform this on themselves
However:
- The skin must be intact
- The operation site must not be obstructed by clothing
- The limb must not be organic
| Tool | Speed Multiplier | |
|---|---|---|
| File:Surgery tool screwdriver.png | Screwdriver | 1x |
| File:Surgery tool scalpel.png | Scalpel | 1.33x |
| File:Surgery tool knife.png | Knife | 2x |
| File:Surgery tool any sharp item.png | Any sharp item | 10x |
| File:Surgery limbmechanic unwrench.png | Unwrench endoskeleton Unwrench a mechanical patient's endoskeleton to access its internals. Clears "bone sawed" surgical state. |
All of these are required:
- The skin must be open
- The patient must be lying down
You may optionally:
- A surgeon may perform this on themselves
However:
- The bone must be intact
- The operation site must not be obstructed by clothing
- The limb must not be organic
| Tool | Speed Multiplier | |
|---|---|---|
| File:Surgery tool wrench.png | Wrench | 1x |
| File:Surgery tool retractor.png | Retractor | 1.33x |
| File:Surgery limbprepare cavity.png | Widen chest cavity Widen a patient's chest cavity to allow for implanting of larger items. |
All of these are required:
- Operate on chest (target chest)
- The skin must be open
- The organs must be cut
- The patient must be lying down
However:
- The chest cavity must not be opened wide
- The operation site must not be obstructed by clothing
| Tool | Speed Multiplier | |
|---|---|---|
| File:Surgery tool retractor.png | Retractor | 1x |
| File:Surgery tool crowbar.png | Crowbar | 1.5x |
| File:Surgery limbmechanic wrench.png | Wrench endoskeleton Wrench a mechanical patient's endoskeleton back into place. Clears "bone sawed" surgical state. |
All of these are required:
- The skin must be open
- The bone must be sawed
- The patient must be lying down
- The limb must have bones
You may optionally:
- A surgeon may perform this on themselves
However:
- The operation site must not be obstructed by clothing
- The limb must not be organic
| Tool | Speed Multiplier | |
|---|---|---|
| File:Surgery tool wrench.png | Wrench | 1x |
| File:Surgery tool retractor.png | Retractor | 1.33x |
| File:Surgery limbadd plastic.png | Apply plastic Apply plastic to a patient's face to to allow for greater customization in following plastic surgery. |
All of these are required:
- The skin must be open
- The patient must be lying down
However:
- The blood vessels must not be unclamped
- Plastic must not be applied
- The operation site must not be obstructed by clothing
| Tool | Speed Multiplier | |
|---|---|---|
| File:Surgery tool plastic.png | Plastic | 1x |
| File:Surgery organbrainwash.png | Neural Brainwashing (Brainwash) A surgical procedure which directly implants a directive into the patient's brain, making it their absolute priority. It can be cleared using a mindshield implant. |
All of these are required:
- Operate on brain (target head)
- The skin must be open
- The organs must be cut
- The bone must be sawed
- The patient must be lying down
However:
- The operation site must not be obstructed by clothing
- The organ must not be cybernetic
| Tool | Speed Multiplier | |
|---|---|---|
| File:Surgery tool hemostat.png | Hemostat | 1.15x |
| File:Surgery tool cutters.png | Cutters | 2x |
| File:Surgery tool package wrapper.png | Package wrapper | 2.85x |
| File:Surgery tool cable coil.png | Cable coil | 6.67x |
| File:Surgery limbbiowarecortex folding.png | Encephalofractoplasty (Cortex Folding) A biological upgrade which folds a patient's cerebral cortex into a fractal pattern, increasing neural density and flexibility. |
All of these are required:
- Operate on head (target head)
- The skin must be open
- The organs must be cut
- The bone must be sawed
- The patient must be lying down
However:
- The operation site must not be obstructed by clothing
- The limb must not be cybernetic
- The patient must not have undergone Encephalofractoplasty (Cortex Folding) OR Encephalopremoplasty (Cortex Imprinting) prior
| Tool | Speed Multiplier | |
|---|---|---|
| File:Surgery tool hands.png | Hands | 1x |
| File:Surgery limbbiowarecortex foldingmechanic.png | Wetware OS Labyrinthian Programming (Cortex Folding) Reprogram a robotic patient's neural network in a downright eldritch programming language, giving space to non-standard neural patterns. |
All of these are required:
- Operate on head (target head)
- The skin must be open
- The organs must be cut
- The bone must be sawed
- The patient must be lying down
However:
- The operation site must not be obstructed by clothing
- The limb must not be organic
- The patient must not have undergone Wetware OS Labyrinthian Programming (Cortex Folding) OR Wetware OS Ver 2.0 (Cortex Imprinting) prior
| Tool | Speed Multiplier | |
|---|---|---|
| File:Surgery tool hands.png | Hands | 1x |
| File:Surgery limbbiowarecortex imprint.png | Encephalopremoplasty (Cortex Imprinting) A biological upgrade which carves a patient's cerebral cortex into a self-imprinting pattern, increasing neural density and resilience. |
All of these are required:
- Operate on head (target head)
- The skin must be open
- The organs must be cut
- The bone must be sawed
- The patient must be lying down
However:
- The operation site must not be obstructed by clothing
- The limb must not be cybernetic
- The patient must not have undergone Encephalofractoplasty (Cortex Folding) OR Encephalopremoplasty (Cortex Imprinting) prior
| Tool | Speed Multiplier | |
|---|---|---|
| File:Surgery tool hands.png | Hands | 1x |
| File:Surgery limbbiowarecortex imprintmechanic.png | Wetware OS Ver 2.0 (Cortex Imprinting) Update a robotic patient's operating system to a "newer version", improving overall performance and resilience. Shame about all the adware. |
All of these are required:
- Operate on head (target head)
- The skin must be open
- The organs must be cut
- The bone must be sawed
- The patient must be lying down
However:
- The operation site must not be obstructed by clothing
- The limb must not be organic
- The patient must not have undergone Wetware OS Labyrinthian Programming (Cortex Folding) OR Wetware OS Ver 2.0 (Cortex Imprinting) prior
| Tool | Speed Multiplier | |
|---|---|---|
| File:Surgery tool hands.png | Hands | 1x |
| File:Surgery organpacifymechanic.png | Aggression Suppression Programming (Pacification) Install malware which permanently inhibits the aggression programming of the patient's neural network, making the patient unwilling to cause direct harm. |
All of these are required:
- Operate on brain (target head)
- The skin must be open
- The bone must be sawed
- The patient must be lying down
However:
- The blood vessels must not be unclamped
- The operation site must not be obstructed by clothing
- The organ must not be organic
| Tool | Speed Multiplier | |
|---|---|---|
| File:Surgery tool multitool.png | Multitool | 1x |
| File:Surgery tool hemostat.png | Hemostat | 2.85x |
| File:Surgery tool screwdriver.png | Screwdriver | 2.85x |
| File:Surgery tool pen.png | Pen | 6.67x |
| File:Surgery organlobotomymechanic.png | Wetware OS Destructive Defragmentation (Lobotomy) An invasive surgical procedure which guarantees removal of almost all brain traumas, but might cause another permanent trauma in return. |
All of these are required:
- Operate on brain (target head)
- The skin must be open
- The bone must be sawed
- The patient must be lying down
However:
- The blood vessels must not be unclamped
- The operation site must not be obstructed by clothing
- The organ must not be organic
| Tool | Speed Multiplier | |
|---|---|---|
| File:Surgery tool multitool.png | Multitool | 1.15x |
| File:Surgery tool energy sword.png | Energy sword | 1.85x |
| File:Surgery tool knife.png | Knife | 2.85x |
| File:Surgery tool shard.png | Shard | 4x |
| File:Surgery tool any sharp edged item.png | Any sharp edged item | 5x |
| File:Surgery basicdissection.png | Experimental Androtomy (Experimental Dissection and Autopsy) An experimental surgical procedure that dissects bodies in exchange for research points at ancient R&D consoles. |
All of these are required:
- Operate on chest (target chest)
- The patient must be lying down
- The patient must be deceased
- The patient must not have been dissected prior
- The skin must be cut or opened
| Tool | Speed Multiplier | |
|---|---|---|
| File:Surgery tool autopsy scanner.png | Autopsy scanner | 1x |
| File:Surgery tool scalpel.png | Scalpel | 1.66x |
| File:Surgery tool knife.png | Knife | 5x |
| File:Surgery tool shard.png | Shard | 10x |
| File:Surgery limbbiowarenerve grounding.png | Xanthoneuroplasty (Grounded Nerves) Reroute a patient's nerves to act as grounding rods, protecting them from electrical shocks. |
All of these are required:
- Operate on chest (target chest)
- The skin must be open
- The organs must be cut
- The bone must be sawed
- The patient must be lying down
However:
- The operation site must not be obstructed by clothing
- The limb must not be cybernetic
- The patient must not have undergone Symneurodesis (Spliced Nerves) OR Xanthoneuroplasty (Grounded Nerves) prior
| Tool | Speed Multiplier | |
|---|---|---|
| File:Surgery tool hands.png | Hands | 1x |
| File:Surgery limbbiowarenerve groundingmechanic.png | System Shock Dampening (Grounded Nerves) Install grounding rods into a robotic patient's nervous system, protecting it from electrical shocks. |
All of these are required:
- Operate on chest (target chest)
- The skin must be open
- The organs must be cut
- The bone must be sawed
- The patient must be lying down
However:
- The operation site must not be obstructed by clothing
- The limb must not be organic
- The patient must not have undergone System Automatic Reset Subroutine (Spliced Nerves) OR System Shock Dampening (Grounded Nerves) prior
| Tool | Speed Multiplier | |
|---|---|---|
| File:Surgery tool hands.png | Hands | 1x |
| File:Surgery limbbionecrosis.png | Bionecroplasty (Necrotic Revival) An experimental procedure which induces the growth of a Romerol tumor inside the patient's brain. |
All of these are required:
- The skin must be open
- The bone must be sawed
- The patient must be lying down
- The limb must have a brain present
Any one of these is required:
- The patient or tool must contain >1u Rezadone
- The patient or tool must contain >1u Zombie Powder
However:
- The blood vessels must not be unclamped
- The operation site must not be obstructed by clothing
- The limb must not already have a Romerol tumor
| Tool | Speed Multiplier | |
|---|---|---|
| File:Surgery tool syringe.png | Syringe | 1x |
| File:Surgery tool pen.png | Pen | 3.33x |
| File:Surgery organbrainwashsleeper.png | Sleeper Agent Implantation (Brainwash) A surgical procedure which directly implants a directive into the patient's brain, making it their absolute priority. It can be cleared using a mindshield implant. |
All of these are required:
- Operate on brain (target head)
- The skin must be open
- The organs must be cut
- The bone must be sawed
- The patient must be lying down
However:
- The operation site must not be obstructed by clothing
- The organ must not be cybernetic
| Tool | Speed Multiplier | |
|---|---|---|
| File:Surgery tool hemostat.png | Hemostat | 1.15x |
| File:Surgery tool cutters.png | Cutters | 2x |
| File:Surgery tool package wrapper.png | Package wrapper | 2.85x |
| File:Surgery tool cable coil.png | Cable coil | 6.67x |
| File:Surgery organbrainwashsleepermechanic.png | Sleeper Agent Programming (Brainwash) A surgical procedure which directly implants a directive into the patient's brain, making it their absolute priority. It can be cleared using a mindshield implant. |
All of these are required:
- Operate on brain (target head)
- The skin must be open
- The organs must be cut
- The bone must be sawed
- The patient must be lying down
However:
- The operation site must not be obstructed by clothing
- The organ must not be organic
| Tool | Speed Multiplier | |
|---|---|---|
| File:Surgery tool multitool.png | Multitool | 1.15x |
| File:Surgery tool hemostat.png | Hemostat | 2x |
| File:Surgery tool cutters.png | Cutters | 2x |
| File:Surgery tool package wrapper.png | Package wrapper | 2.85x |
| File:Surgery tool cable coil.png | Cable coil | 6.67x |
| File:Surgery organlobotomy.png | Lobotomy (Lobotomy) An invasive surgical procedure which guarantees removal of almost all brain traumas, but might cause another permanent trauma in return. |
All of these are required:
- Operate on brain (target head)
- The skin must be open
- The bone must be sawed
- The patient must be lying down
However:
- The blood vessels must not be unclamped
- The operation site must not be obstructed by clothing
- The organ must not be cybernetic
| Tool | Speed Multiplier | |
|---|---|---|
| File:Surgery tool scalpel.png | Scalpel | 1.15x |
| File:Surgery tool energy sword.png | Energy sword | 0.55x |
| File:Surgery tool knife.png | Knife | 2.85x |
| File:Surgery tool shard.png | Shard | 4x |
| File:Surgery tool any sharp edged item.png | Any sharp edged item | 5x |
| File:Surgery limbbiowaremuscled veins.png | Myovasculoplasty (Muscled Veins) Add a muscled membrane to a patient's veins, allowing them to pump blood without a heart. |
All of these are required:
- Operate on chest (target chest)
- The skin must be open
- The organs must be cut
- The bone must be sawed
- The patient must be lying down
However:
- The operation site must not be obstructed by clothing
- The limb must not be cybernetic
- The patient must not have undergone Symvasculodesis (Vein Threading) OR Myovasculoplasty (Muscled Veins) prior
| Tool | Speed Multiplier | |
|---|---|---|
| File:Surgery tool hands.png | Hands | 1x |
| File:Surgery limbbiowaremuscled veinsmechanic.png | Hydraulics Redundancy Subroutine (Muscled Veins) Add redundancies to a robotic patient's hydraulic system, allowing it to pump fluids without an engine or pump. |
All of these are required:
- Operate on chest (target chest)
- The skin must be open
- The organs must be cut
- The bone must be sawed
- The patient must be lying down
However:
- The operation site must not be obstructed by clothing
- The limb must not be organic
- The patient must not have undergone Hydraulics Routing Optimization (Threaded Veins) OR Hydraulics Redundancy Subroutine (Muscled Veins) prior
| Tool | Speed Multiplier | |
|---|---|---|
| File:Surgery tool hands.png | Hands | 1x |
| File:Surgery organpacify.png | Paxopsy (Pacification) A surgical procedure which permanently inhibits the aggression center of the brain, making the patient unwilling to cause direct harm. |
All of these are required:
- Operate on brain (target head)
- The skin must be open
- The bone must be sawed
- The patient must be lying down
However:
- The blood vessels must not be unclamped
- The operation site must not be obstructed by clothing
- The organ must not be cybernetic
| Tool | Speed Multiplier | |
|---|---|---|
| File:Surgery tool hemostat.png | Hemostat | 1x |
| File:Surgery tool screwdriver.png | Screwdriver | 2.85x |
| File:Surgery tool pen.png | Pen | 6.67x |
| File:Surgery organfix wings.png | Pteroplasty (Wing Repair) A surgical procedure that repairs damaged wings using Synthflesh. |
All of these are required:
- Operate on moth wings (target chest)
- The skin must be open
- The patient must be lying down
- The wings must be burnt
- The patient must be dosed with >=5u Synthflesh
However:
- The blood vessels must not be unclamped
- The operation site must not be obstructed by clothing
- If the limb has bones, they must be intact
| Tool | Speed Multiplier | |
|---|---|---|
| File:Surgery tool hemostat.png | Hemostat | 1.15x |
| File:Surgery tool screwdriver.png | Screwdriver | 2.85x |
| File:Surgery tool pen.png | Pen | 6.67x |
| File:Surgery organbrainwashmechanic.png | Neural Reprogramming (Brainwash) Install malware which directly implants a directive into the robotic patient's operating system, making it their absolute priority. It can be cleared using a mindshield implant. |
All of these are required:
- Operate on brain (target head)
- The skin must be open
- The organs must be cut
- The bone must be sawed
- The patient must be lying down
However:
- The operation site must not be obstructed by clothing
- The organ must not be organic
| Tool | Speed Multiplier | |
|---|---|---|
| File:Surgery tool multitool.png | Multitool | 1.15x |
| File:Surgery tool hemostat.png | Hemostat | 2x |
| File:Surgery tool cutters.png | Cutters | 2x |
| File:Surgery tool package wrapper.png | Package wrapper | 2.85x |
| File:Surgery tool cable coil.png | Cable coil | 6.67x |
| File:Surgery limbbiowareligament hook.png | Arthroplasty (Ligament Hooks) Reshape a patient's ligaments to allow limbs to be manually reattached if severed - at the cost of making them easier to detach. |
All of these are required:
- Operate on chest (target chest)
- The skin must be open
- The organs must be cut
- The bone must be sawed
- The patient must be lying down
However:
- The operation site must not be obstructed by clothing
- The limb must not be cybernetic
- The patient must not have undergone Arthroplasty (Ligament Hooks) OR Arthrorrhaphy (Ligament Reinforcement) prior
| Tool | Speed Multiplier | |
|---|---|---|
| File:Surgery tool hands.png | Hands | 1x |
| File:Surgery limbbiowareligament hookmechanic.png | Anchor Point Snaplocks (Ligament Hooks) Refactor a robotic patient's limb joints to allow for rapid deatchment, allowing limbs to be manually reattached if severed - at the cost of making them easier to detach as well. |
All of these are required:
- Operate on chest (target chest)
- The skin must be open
- The organs must be cut
- The bone must be sawed
- The patient must be lying down
However:
- The operation site must not be obstructed by clothing
- The limb must not be organic
- The patient must not have undergone Anchor Point Snaplocks (Ligament Hooks) OR Anchor Point Reinforcement (Ligament Reinforcement) prior
| Tool | Speed Multiplier | |
|---|---|---|
| File:Surgery tool hands.png | Hands | 1x |
| File:Surgery limbbiowarenerve splicing.png | Symneurodesis (Spliced Nerves) Splice a patient's nerves together to make them more resistant to stuns. |
All of these are required:
- Operate on chest (target chest)
- The skin must be open
- The organs must be cut
- The bone must be sawed
- The patient must be lying down
However:
- The operation site must not be obstructed by clothing
- The limb must not be cybernetic
- The patient must not have undergone Symneurodesis (Spliced Nerves) OR Xanthoneuroplasty (Grounded Nerves) prior
| Tool | Speed Multiplier | |
|---|---|---|
| File:Surgery tool hands.png | Hands | 1x |
| File:Surgery limbbiowarenerve splicingmechanic.png | System Automatic Reset Subroutine (Spliced Nerves) Upgrade a robotic patient's automatic systems, allowing it to better resist stuns. |
All of these are required:
- Operate on chest (target chest)
- The skin must be open
- The organs must be cut
- The bone must be sawed
- The patient must be lying down
However:
- The operation site must not be obstructed by clothing
- The limb must not be organic
- The patient must not have undergone System Automatic Reset Subroutine (Spliced Nerves) OR System Shock Dampening (Grounded Nerves) prior
| Tool | Speed Multiplier | |
|---|---|---|
| File:Surgery tool hands.png | Hands | 1x |
| File:Surgery limbbiowareligament reinforcement.png | Arthrorrhaphy (Ligament Reinforcement) Strengthen a patient's ligaments to make dismemberment more difficult, at the cost of making nerve connections easier to interrupt. |
All of these are required:
- Operate on chest (target chest)
- The skin must be open
- The organs must be cut
- The bone must be sawed
- The patient must be lying down
However:
- The operation site must not be obstructed by clothing
- The limb must not be cybernetic
- The patient must not have undergone Arthroplasty (Ligament Hooks) OR Arthrorrhaphy (Ligament Reinforcement) prior
| Tool | Speed Multiplier | |
|---|---|---|
| File:Surgery tool hands.png | Hands | 1x |
| File:Surgery limbbiowareligament reinforcementmechanic.png | Anchor Point Reinforcement (Ligament Reinforcement) Reinforce a robotic patient's limb joints to prevent dismemberment, at the cost of making nerve connections easier to interrupt. |
All of these are required:
- Operate on chest (target chest)
- The skin must be open
- The organs must be cut
- The bone must be sawed
- The patient must be lying down
However:
- The operation site must not be obstructed by clothing
- The limb must not be organic
- The patient must not have undergone Anchor Point Snaplocks (Ligament Hooks) OR Anchor Point Reinforcement (Ligament Reinforcement) prior
| Tool | Speed Multiplier | |
|---|---|---|
| File:Surgery tool hands.png | Hands | 1x |
| File:Surgery basictend woundsupgraded.png | Tend Wounds+ Perform superficial wound care on a patient's bruises and burns. |
All of these are required:
- Operate on chest (target chest)
- The patient must be lying down
- The patient must have brute or burn damage
- The skin must be cut or opened
However:
- The patient must not be robotic
| Tool | Speed Multiplier | |
|---|---|---|
| File:Surgery tool hemostat.png | Hemostat | 1x |
| File:Surgery tool screwdriver.png | Screwdriver | 1.5x |
| File:Surgery tool cutters.png | Cutters | 1.67x |
| File:Surgery tool pen.png | Pen | 1.8x |
| File:Surgery basictend woundsupgradedmaster.png | Tend Wounds++ Perform superficial wound care on a patient's bruises and burns. |
All of these are required:
- Operate on chest (target chest)
- The patient must be lying down
- The patient must have brute or burn damage
- The skin must be cut or opened
However:
- The patient must not be robotic
| Tool | Speed Multiplier | |
|---|---|---|
| File:Surgery tool hemostat.png | Hemostat | 1x |
| File:Surgery tool screwdriver.png | Screwdriver | 1.5x |
| File:Surgery tool cutters.png | Cutters | 1.67x |
| File:Surgery tool pen.png | Pen | 1.8x |
| File:Surgery basictend woundscombo.png | Advanced Tend Wounds Perform superficial wound care on a patient's bruises and burns. |
All of these are required:
- Operate on chest (target chest)
- The patient must be lying down
- The patient must have brute or burn damage
- The skin must be cut or opened
However:
- The patient must not be robotic
| Tool | Speed Multiplier | |
|---|---|---|
| File:Surgery tool hemostat.png | Hemostat | 1x |
| File:Surgery tool screwdriver.png | Screwdriver | 1.5x |
| File:Surgery tool cutters.png | Cutters | 1.67x |
| File:Surgery tool pen.png | Pen | 1.8x |
| File:Surgery basictend woundscomboupgraded.png | Advanced Tend Wounds+ Perform superficial wound care on a patient's bruises and burns. |
All of these are required:
- Operate on chest (target chest)
- The patient must be lying down
- The patient must have brute or burn damage
- The skin must be cut or opened
However:
- The patient must not be robotic
| Tool | Speed Multiplier | |
|---|---|---|
| File:Surgery tool hemostat.png | Hemostat | 1x |
| File:Surgery tool screwdriver.png | Screwdriver | 1.5x |
| File:Surgery tool cutters.png | Cutters | 1.67x |
| File:Surgery tool pen.png | Pen | 1.8x |
| File:Surgery basictend woundscomboupgradedmaster.png | Advanced Tend Wounds++ Perform superficial wound care on a patient's bruises and burns. |
All of these are required:
- Operate on chest (target chest)
- The patient must be lying down
- The patient must have brute or burn damage
- The skin must be cut or opened
However:
- The patient must not be robotic
| Tool | Speed Multiplier | |
|---|---|---|
| File:Surgery tool hemostat.png | Hemostat | 1x |
| File:Surgery tool screwdriver.png | Screwdriver | 1.5x |
| File:Surgery tool cutters.png | Cutters | 1.67x |
| File:Surgery tool pen.png | Pen | 1.8x |
| File:Surgery limbbiowarevein threading.png | Symvasculodesis (Vein Threading) Weave a patient's veins into a reinforced mesh, reducing blood loss from injuries. |
All of these are required:
- Operate on chest (target chest)
- The skin must be open
- The organs must be cut
- The bone must be sawed
- The patient must be lying down
However:
- The operation site must not be obstructed by clothing
- The limb must not be cybernetic
- The patient must not have undergone Symvasculodesis (Vein Threading) OR Myovasculoplasty (Muscled Veins) prior
| Tool | Speed Multiplier | |
|---|---|---|
| File:Surgery tool hands.png | Hands | 1x |
| File:Surgery limbbiowarevein threadingmechanic.png | Hydraulics Routing Optimization (Threaded Veins) Optimize the routing of a robotic patient's hydraulic system, reducing fluid loss from leaks. |
All of these are required:
- Operate on chest (target chest)
- The skin must be open
- The organs must be cut
- The bone must be sawed
- The patient must be lying down
However:
- The operation site must not be obstructed by clothing
- The limb must not be organic
- The patient must not have undergone Hydraulics Routing Optimization (Threaded Veins) OR Hydraulics Redundancy Subroutine (Muscled Veins) prior
| Tool | Speed Multiplier | |
|---|---|---|
| File:Surgery tool hands.png | Hands | 1x |
| File:Surgery basicviral bonding.png | Viroplasty (Viral Bonding) A surgical procedure that forces a symbiotic relationship between a virus and its host. The patient will be completely immune to the effects of the virus, but will carry and spread it to others. |
All of these are required:
- Operate on chest (target chest)
- The skin must be open
- The organs must be cut
- The patient must be lying down
- The patient must have a virus to bond
- The patient must be dosed with >=1u Spaceacillin
- The patient must be dosed with >=1u Virus Food
- The patient must be dosed with >=1u Formaldehyde
However:
- The operation site must not be obstructed by clothing
- The patient must not be robotic
| Tool | Speed Multiplier | |
|---|---|---|
| File:Surgery tool cautery.png | Cautery | 1x |
| File:Surgery tool welder.png | Welder | 2x |
| File:Surgery tool any heat source.png | Any heat source | 3.33x |